EMAS MK1KIM2 Microswitch Middle Hinge Lever (1 C.O. Contact)
EMAS MK1KIM2 Microswitch Middle Hinge Lever (1 C.O. Contact)
EMAS MK1KIM2 Microswitch Middle Hinge Lever (1 C.O. Contact)
  • Load image into Gallery viewer, EMAS MK1KIM2 Microswitch Middle Hinge Lever (1 C.O. Contact)
  • Load image into Gallery viewer, EMAS MK1KIM2 Microswitch Middle Hinge Lever (1 C.O. Contact)
  • Load image into Gallery viewer, EMAS MK1KIM2 Microswitch Middle Hinge Lever (1 C.O. Contact)

EMAS MK1KIM2 Microswitch Middle Hinge Lever (1 C.O. Contact)

Vendor
EMAS
Regular price
£5.09 (Exc. VAT)
Sale price
£5.09 (Exc. VAT)
Regular price
£5.66 (Exc. VAT)
Sold out
Unit price
per 
Shipping calculated at checkout.

MPN: MK1KIM2

Metal Medium Lever 1CO MK1 Series Micro Switch

The MK1KIM2 steps up to a medium-length metal lever, giving a bit more reach and mechanical advantage than the short-lever MK1KIM1 while keeping the same changeover contact flexibility. It's a solid middle-ground choice when the short lever's clearance is too tight but the long lever's reach isn't needed.

10A rated for resistive loads or 6A for inductive. By choosing EMAS you can be assured of safety and quality, microswitches are UKCA and CE marked.

Changeover contact allows for normally closed or normally open wiring. Fast on crimps or soldered connection.

Technical Details

Product
Micro Switch
Contact
1CO
Actuator
Medium Lever
Current (Ie)
6 A (250V AC)
Usage Category
AC15
Mechanical Life (Min Qty)
10000000
Electrical Life (Min Qty)
100000
Operating Frequency (On-Off/Hour)
Mech. 3000 Elec. 1200
Insulation Voltage (Ui)
660V
Impulse Withstand Voltage (Uimp)
2.5 kV
Dielectric Strength (Body-Contact)
1,890V AC
Dielectric Strength (Contact-Contact)
1,890V AC
Isolation Resistance
10 MΩ min. (500V DC)
Operating Temperature
-25 / +80 °C
Pollution Degree
3
Protection Degree
IP20
Contact Material
AgNi
Cable Section
Terminal 6,3*0,8 mm
Short Circuit Breaking Capacity (Ics)
1 kA
Serial
MK1 Series
Actuator Material
Metal

Frequently Asked Questions

Why is it rated both 6A and 10A?
6A is the standard AC15 inductive load rating; 10A applies to purely resistive loads. Check which load type your circuit switches — inductive loads (motors, solenoids) need the lower 6A figure.

Can I wire this as normally open or normally closed?
Yes — the changeover (C.O.) contact supports either wiring configuration from the same part.

Should I choose this over the short or long lever version?
The medium lever suits installations where the short lever (MK1KIM1) doesn't have enough reach, but a long lever (MK1KIM3) isn't needed. Choose based on your actuator's approach distance and available clearance.

Is this suitable for washdown areas?
It's IP20 rated, suited to standard indoor equipment rather than washdown or outdoor environments.

Industry Applications

  • Machine guarding & position sensing — general-purpose detection with moderate reach
  • Panel builders & OEMs — end-of-travel and interlock switching
  • Appliance & equipment repair — replacement microswitch for a wide range of applications