Novus N322 - Digital Thermostat On/Off Control - PT100 (100-240V)
Novus N322 - Digital Thermostat On/Off Control - PT100 (100-240V)
Novus N322 - Digital Thermostat On/Off Control - PT100 (100-240V)
  • Load image into Gallery viewer, Novus N322 - Digital Thermostat On/Off Control - PT100 (100-240V)
  • Load image into Gallery viewer, Novus N322 - Digital Thermostat On/Off Control - PT100 (100-240V)
  • Load image into Gallery viewer, Novus N322 - Digital Thermostat On/Off Control - PT100 (100-240V)

Novus N322 - Digital Thermostat On/Off Control - PT100 (100-240V)

Vendor
Novus
Regular price
£54.00 (Exc. VAT)
Sale price
£54.00 (Exc. VAT)
Regular price
£61.00 (Exc. VAT)
Sold out
Unit price
per 
Shipping calculated at checkout.

MPN: 8032201022

The Novus N322 PT100 is a digital temperature controller for heating or cooling purposes with 2 independent setpoints, giving 2 relay outputs with independent parameters for direct control of elements, compressors, fans, and valves — no SSR required for simple installation, backed by a 16A relay with Novus reliability. It's a trusted product for replacing or upgrading bimetallic and capillary thermostats, retrofitting HVAC, machinery and OEM builds, and catering equipment.

Operating range is -50 to +300 degrees Celsius. The output control can be refined with adjustable hysteresis and on/off time delays, giving a gentle response with thermostatic control. The N322 will replace or upgrade the majority of manual or programmable thermostats used in industry.

3 Year Manufacturer Warranty — backed by our UK-based technical support

Novus N322 Datasheet Download

Novus N322 Manual Download

Technical Details

SIZE: 75 x 33 x 75 mm. PANEL CUTOUT: 70 x 29 mm (+0.5 -0.0 mm). SUPPLY: 100~240 Vac (±10%)

INPUT: PT100

OUT1: Relay SPDT; 1 HP 250 Vac / 1/3 HP 125 Vac (16 A Resistive). OUT2: Relay 3 A / 250 Vac, SPST

INPUT SENSOR: Pt100; Range: -50 to 300°C (-58 to 572°F); α=0.00385; 3 wires; Accuracy: 0.7°C (1.3°F); per IEC-751 standards

Frequently Asked Questions

Do I need a separate SSR to switch heating/cooling loads?
No — the 16A relay output switches elements, compressors, fans, and valves directly, no SSR required.

What's the difference between the PT100 and J/K/T versions?
The input sensor type — this model offers tighter accuracy (0.7°C) over -50 to 300°C with Pt100; the J/K/T version covers a wider range up to 1000°C.

Can I get this with RS485 for remote monitoring?
Yes — see the RS485 version for Modbus-based remote monitoring.

Industry Applications

  • HVAC Retrofit — direct upgrade path from bimetallic or capillary thermostats.
  • Precision Process Applications — Pt100 input gives tighter accuracy than thermocouple alternatives.
  • OEM Machinery — 16A relay drives elements, compressors, or fans without an SSR.