Sales & Technical Support: Mon–Fri 09:00–17:00 +44 (0)1824 520565
Novus DigiRail Connect Universal Ethernet IO Expansion Modules (Modbus, RS485) - additional product photo

Novus DigiRail Connect RAMIX | Ethernet IO Module Modbus TCP/RTU (2AI / 2AO / 4DI / 2 Relay)

Vendor
Novus
Regular price
£230.00 (Exc. VAT)
Sale price
£230.00 (Exc. VAT)
Regular price
(Exc. VAT)
Sold out
Unit price
per 
Shipping calculated at checkout.

MPN: 8811611440

Delivery: Factory Order, Delivered In 7-14 Days

The Novus DigiRail Connect RAMIX 2AI / 2AO / 4DI / 2 Relay (8811611440) combines 2 isolated universal analogue inputs, 2 isolated analogue outputs, 4 digital inputs and 2 relay outputs in one DIN rail module. The analogue inputs read thermocouples, Pt100/Pt1000, NTC and mV, V or mA signals directly at 16-bit resolution, the analogue outputs provide 0-20mA, 4-20mA or 0-10V, and the relays give volt-free contacts for alarms, contactor coils and valves up to 250Vac.

Every DigiRail Connect model has Ethernet, RS485 and Micro USB on board. It works as a Modbus RTU slave on an existing RS485 network or as a Modbus TCP server on Ethernet, and can act as a transparent Modbus TCP to RTU gateway, so an Ethernet PLC or SCADA system can read RS485 instruments wired to its terminals with no register mapping. Configuration and I/O testing use free Novus NXperience software over USB.

Lead time: made to order by Novus, typically 1–2 weeks to dispatch.

DigiRail Connect Range

All four DigiRail Connect models share the same Ethernet/RS485 hardware and software. Choose by the I/O mix you need:

Only need analogue inputs on RS485? The lower-cost Novus DigiRail-2A converts two thermocouple, Pt100, mV, V or mA signals to Modbus RTU.

✅ 3 Year Manufacturer Warranty — backed by our UK-based technical support

PDFNovus DigiRail Connect Datasheet Download

PDFNovus DigiRail Connect Manual Download

Technical Details

Order code: 8811611440 (DigiRail Connect RAMIX 2AI / 2AO / 4DI / 2RL ETH)

Analogue inputs: 2, isolated, universal: thermocouple J, K, T, N, E, R, S, B; Pt100, Pt1000, NTC; 0-60mV, 0-5V, 0-10V, 0-20mA, 4-20mA. 16-bit resolution

Analogue outputs: 2, isolated, 0-20mA, 4-20mA or 0-10V. 12-bit resolution

Digital inputs: 4, PNP, NPN or dry contact, configurable counter function

Relay outputs: 2, switching voltage up to 250Vac, resistive loads (see manual for per-channel current rating)

Communication: Ethernet 10/100 Mb/s (IEEE 802.3u), RS485, Micro USB

Protocols: Modbus TCP server, Modbus RTU slave, transparent Modbus TCP to RTU gateway

Configuration software: Novus NXperience (free, via USB)

Power supply: 10-36 Vdc, 5W max (20mA typical)

Operating conditions: -20 to 60°C, 5-95% RH non-condensing

Enclosure: ABS+PC, 35mm DIN rail mounting

Frequently Asked Questions

What can the analogue inputs read directly?
Thermocouples (J, K, T, N, E, R, S, B), Pt100, Pt1000 and NTC sensors, plus 0-60mV, 0-5V, 0-10V, 0-20mA and 4-20mA signals. Each channel is configured independently in NXperience.

Should I choose this relay model or the RAMIX 3DO?
Choose this model when you need volt-free contacts or to switch AC loads such as alarms and contactor coils. The 3DO version has PNP transistor outputs for PLC-level DC signals and pulsing.

Can it control a heater or motor?
The relays are rated for resistive loads at up to 250Vac. For heaters, motors or other large loads, use a relay to drive a contactor coil such as the EMAS HN0910NUE, with control logic in your PLC or SCADA.

Can it bridge RS485 devices onto Ethernet?
Yes. In gateway mode it passes Modbus TCP requests to RTU slaves wired to its RS485 terminals with no register mapping, so an Ethernet PLC can read existing RS485 controllers and meters.

Industry Applications

  • Temperature monitoring & alarms — reads thermocouples or Pt100 sensors and trips relay alarms from SCADA set points.
  • Remote analogue control — sends 0-10V or 4-20mA references to drives and valves while switching run signals.
  • Building management — combines sensor inputs, analogue outputs and plant switching in one BMS module.