Compact, Hands-Free Control: Single Pedal Foot Switch With 1NO+1NC
The EMAS PDNS11BX10 is a lightweight yellow plastic foot switch with a single pedal and no guard. It has one normally open and one normally closed contact, so the same pedal can start a cycle and break an interlock, or give a run signal while dropping out another circuit. It is the simple, low-cost choice for bench tools, sewing and packing machines, test rigs and any job where the operator needs both hands free.
Where a pedal could be pressed accidentally, for example on presses or guillotines, choose the guarded aluminium EMAS PDKS11BX10 instead.
MPN PDNS11BX10
- Single pedal, momentary action, no guard
- 1NO + 1NC contacts rated 3A at 240V AC (AC15)
- IP65 sealed, -25 to +80 °C
- 1 million mechanical operations (EMAS data)
EMAS PDNS11BX10 Datasheet Download
Technical Details
| Product | Foot switch |
| Pedal | Single |
| Guard | Without protection guard |
| Contacts | 1NO+1NC |
| Colour | Yellow |
| Body Material | Plastic |
| Current (Ie) | 3A (240V AC) |
| Usage Category | AC15 |
| Mechanical Life | 1,000,000 operations (min.) |
| Electrical Life | 100,000 operations (min.) |
| Operating Frequency (On-Off/Hour) | Mech. 1800, Elec. 1200 |
| Insulation Voltage (Ui) | 300V |
| Impulse Withstand Voltage (Uimp) | 2.5 kV |
| Operating Temperature | -25 / +80 °C |
| Protection Degree | IP65 |
| Contact Material | AgNi |
| Cable Section | 1.5-2.5 mm² |
| Screw Torque | 1.5 Nm |
| Short Circuit Breaking Capacity (Ics) | 1 kA |
| Standards | TS EN 60947-5-1, UL 508, VDE 0660 |
| Series | PDN Series |
Frequently Asked Questions
When do I need a guarded foot switch instead?
Use a guarded switch wherever an accidental press could cause harm, such as on presses, guillotines or punching machines. The guard stops the pedal being operated by a dropped object or a misplaced foot. This PDNS11BX10 has no guard and suits lower-risk tasks.
How do I use the N.O. and N.C. contacts?
The N.O. contact closes while the pedal is pressed and is normally used to start or run. The N.C. contact opens while pressed, useful for interlocks or for a fail-safe signal to a PLC.
Can it switch a motor or heater directly?
No. The contacts are control-rated (3A AC15). Use the foot switch to drive a contactor, relay or PLC/inverter input.
Is it suitable for wet or dusty floors?
Yes. It is sealed to IP65 against dust and low-pressure water jets.
Industry Applications
- Bench tools & workshops — hands-free start for grinders, drills, heat sealers and test fixtures
- Packing & textile machines — simple pedal control for sewing, bagging and labelling equipment
- Conveyor & drive jog — a run signal to an inverter or contactor while the operator handles the product
Troubleshooting & Guides
- AG Inverter Drive Control — wiring a foot switch to an inverter run input
- Faultfinding — tracing control circuit faults
- Knowledge Base — all our technical guides in one place