{"product_id":"emas-pv7e30b444-crane-pendant-3-axis-double-speed-emergency","title":"EMAS PV7E30B444 - Crane Pendant, 3-Axis Double Speed + Emergency Stop (IP65)","description":"\u003ch2\u003e\u003cstrong\u003e7-Hole Crane Pendant: Three Axes, Double Speed, Emergency Stop\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEMAS PV7E30B444\u003c\/strong\u003e is a 7-hole handheld pendant station for cranes and hoists that need three motion axes from one control, for example hoist up\/down, trolley left\/right and bridge travel forward\/back. It has six double-speed pushbutton positions (a light press for slow, a firmer press for full speed) and a 30mm emergency stop with a 1NC contact in the top position.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMPN PV7E30B444\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThree-axis control\u003c\/strong\u003e - six double-speed pushbutton positions in one station\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEmergency stop\u003c\/strong\u003e - 30mm mushroom head with 1NC contact in hole 1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65 handheld enclosure\u003c\/strong\u003e - for workshop, yard and outdoor crane duty\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated 4A at 250V AC (AC15)\u003c\/strong\u003e - for control circuits to contactors or drives\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDownloads: \u003ca href=\"https:\/\/www.emaselectric.com\/Export\/Datasheet?productCode=PV7E30B444\u0026amp;languageCode=en\" target=\"_blank\" rel=\"noopener\"\u003eEMAS PV7E30B444 datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eCrane pendant station\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e7 hole\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eSpeed\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eDouble speed\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eHole 1\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eEmergency stop, 1NC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCurrent (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e4A (250V AC)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eUsage Category\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eAC15\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMechanical \/ Electrical Life\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1,000,000 \/ 100,000 operations (min.)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e900 operations\/hour\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e300V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e2.5kV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e2,500V AC body-contact \/ 1,500V AC contact-contact\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eIsolation Resistance\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e10MΩ (500V DC)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eShort Circuit Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1kA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eContact Material\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eAgNi\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.5-2.5mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.5Nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e-15°C to +80°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eIP65\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eEMAS PV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from the 5-hole PV5E30B44?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-pv5e30b44-crane-pendant-2-axis-double-speed-emergency\" style=\"color: rgb(43, 0, 255);\"\u003ePV5E30B44\u003c\/a\u003e\u003c\/strong\u003e controls two motion axes. The PV7E30B444 adds a third axis, so one operator can run hoist, trolley and long travel from a single pendant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow does double speed work?\u003c\/strong\u003e\u003cbr\u003eEach pushbutton has two positions. Pressing to the first position gives the slow or jog signal, and pressing fully gives the full-speed signal, so the crane can be positioned precisely and then moved quickly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat contact does the emergency stop provide?\u003c\/strong\u003e\u003cbr\u003eA single normally closed (1NC) contact, intended to drop out the main contactor or safety relay in the crane control circuit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be used outdoors?\u003c\/strong\u003e\u003cbr\u003eYes. The enclosure is rated IP65, protected against dust and low-pressure water jets.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverhead and gantry cranes\u003c\/strong\u003e - three-axis hoist, trolley and travel control from one pendant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorkshop lifting equipment\u003c\/strong\u003e - jog and full-speed positioning of loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCrane builders and maintenance\u003c\/strong\u003e - a direct replacement station for three-motor crane controls\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFewer axes needed? See the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-pv5e30b44-crane-pendant-2-axis-double-speed-emergency\" style=\"color: rgb(43, 0, 255);\"\u003eEMAS PV5E30B44 (5-hole, double speed)\u003c\/a\u003e\u003c\/strong\u003e or \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-pv5e30b22-crane-pendant-2-axis-single-speed-emergency\" style=\"color: rgb(43, 0, 255);\"\u003ePV5E30B22 (5-hole, single speed)\u003c\/a\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How is this different from the 5-hole PV5E30B44?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The PV5E30B44 controls two motion axes. The PV7E30B444 adds a third axis, so one operator can run hoist, trolley and long travel from a single pendant.\"}}, {\"@type\": \"Question\", \"name\": \"How does double speed work?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Each pushbutton has two positions. Pressing to the first position gives the slow or jog signal, and pressing fully gives the full-speed signal, so the crane can be positioned precisely and then moved quickly.\"}}, {\"@type\": \"Question\", \"name\": \"What contact does the emergency stop provide?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"A single normally closed (1NC) contact, intended to drop out the main contactor or safety relay in the crane control circuit.\"}}, {\"@type\": \"Question\", \"name\": \"Can it be used outdoors?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The enclosure is rated IP65, protected against dust and low-pressure water jets.\"}}]}\n\u003c\/script\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57755286995317,"sku":"PV7E30B444","price":92.8,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PV7E30B444_20_1.jpg?v=1794352745","url":"https:\/\/www.production-automation.co.uk\/products\/emas-pv7e30b444-crane-pendant-3-axis-double-speed-emergency","provider":"Production Automation","version":"1.0","type":"link"}