{"product_id":"emas-psa063kd234s-63a-changeover-switch-2-pole-1-0-2","title":"EMAS PSA063KD234S - 63A Changeover Switch 2 Pole, 1-0-2, 64x64mm (IP54)","description":"\u003ch2\u003e\u003cstrong\u003e63A 2-Pole Changeover Switch With Centre Off (1-0-2)\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eEMAS PSA063KD234S\u003c\/strong\u003e is a panel-mounted rotary cam changeover switch rated 63A (AC21A). It has three positions, 1-0-2, with off in the centre, and switches two poles, so on a single-phase circuit both line and neutral are transferred together. Typical uses are selecting between two supplies (for example mains and an alternative supply) or switching one supply between two loads, with a guaranteed off position between them so the two sides are never connected together.\u003c\/p\u003e\u003cp\u003eFor lighter loads see the \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-psa032kd234s-32a-changeover-switch-2-pole-1-0-2\"\u003eEMAS PSA032KD234S 32A changeover switch\u003c\/a\u003e. For a simple on\/off isolator see the \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-psa063ak341e-63a-3-pole-rotary-isolator\"\u003eEMAS PSA063AK341E 63A rotary isolator\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN PSA063KD234S\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e63A\u003c\/strong\u003e rated current, AC21A, 690V insulation voltage\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1-0-2 changeover\u003c\/strong\u003e with centre off, 60° switching angle\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2 poles\u003c\/strong\u003e, switches line and neutral together on single-phase circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e64x64mm\u003c\/strong\u003e front plate, IP54\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSafety note:\u003c\/strong\u003e where this switch is used to change over between two sources of supply (for example mains and a generator), the installation must be designed and fitted by a competent electrician in line with BS 7671, and must prevent the two supplies ever being connected in parallel. Check with your electricity supplier before connecting an alternative supply to a property.\u003c\/p\u003e\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/EMAS-PSA063KD234S-Datasheet.pdf\" title=\"EMAS PSA063KD234S Datasheet Download\"\u003eEMAS PSA063KD234S Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eTechnical Details\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCam switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitch Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eChangeover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePositions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1-0-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrame Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e64 x 64 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUsage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC21A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSwitching Angle\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60°\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,000 operations (min.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50,000 operations (min.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-25 \/ +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgNi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTS EN 60947-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePSA Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat does 1-0-2 mean?\u003c\/strong\u003e\u003cbr\u003ePosition 1 connects the common terminals to the first side, 0 is off with everything disconnected, and position 2 connects to the second side. The switch must pass through off when moving between 1 and 2.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan I use it as a generator changeover switch?\u003c\/strong\u003e\u003cbr\u003eIt can form part of a manual changeover arrangement on a single-phase circuit up to 63A, because it switches both line and neutral and has a centre off. The installation must be designed and fitted by a competent electrician to BS 7671.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs it suitable for switching motors?\u003c\/strong\u003e\u003cbr\u003eIt is rated AC21A, which covers resistive and mixed loads. For selecting or reversing motors, check the motor current against the switch rating and use a contactor where frequent switching under load is needed.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes it come with an enclosure?\u003c\/strong\u003e\u003cbr\u003eNo. It is a panel-mounting switch with a 64x64mm front plate, for fitting into a door or enclosure lid.\u003c\/p\u003e\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply selection\u003c\/strong\u003e — manual changeover between two single-phase supplies with a guaranteed off position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLoad selection\u003c\/strong\u003e — switching one supply between two larger heaters, kilns or circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTest \u0026amp; maintenance panels\u003c\/strong\u003e — selecting between duty and standby equipment\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTroubleshooting \u0026amp; Guides\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/faultfinding\"\u003eFaultfinding\u003c\/a\u003e — tracing supply and control circuit faults\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/knowledge-base\"\u003eKnowledge Base\u003c\/a\u003e — all our technical guides in one place\u003c\/li\u003e\n\u003c\/ul\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What does 1-0-2 mean?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Position 1 connects the common terminals to the first side, 0 is off with everything disconnected, and position 2 connects to the second side. The switch must pass through off when moving between 1 and 2.\"}},{\"@type\":\"Question\",\"name\":\"Can I use it as a generator changeover switch?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It can form part of a manual changeover arrangement on a single-phase circuit up to 63A, because it switches both line and neutral and has a centre off. The installation must be designed and fitted by a competent electrician to BS 7671.\"}},{\"@type\":\"Question\",\"name\":\"Is it suitable for switching motors?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It is rated AC21A, which covers resistive and mixed loads. For selecting or reversing motors, check the motor current against the switch rating and use a contactor where frequent switching under load is needed.\"}},{\"@type\":\"Question\",\"name\":\"Does it come with an enclosure?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. It is a panel-mounting switch with a 64x64mm front plate, for fitting into a door or enclosure lid.\"}}]}\u003c\/script\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57783560831349,"sku":"PSA063KD234S","price":52.09,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PSA063KD234S.jpg?v=1794824940","url":"https:\/\/www.production-automation.co.uk\/products\/emas-psa063kd234s-63a-changeover-switch-2-pole-1-0-2","provider":"Production Automation","version":"1.0","type":"link"}