{"product_id":"emas-cm707dj41-metal-body-joystick-spring-return-4-positions","title":"EMAS CM707DJ41 - Metal Body Joystick Spring Return, 4 Positions (IP65 2 N.O. + 2 N.O.)","description":"\u003ch2\u003e\u003cstrong\u003eRugged 4-Way Spring Return Joystick In A Die-Cast Metal Body\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eEMAS CM707DJ41\u003c\/strong\u003e is a 22mm metal-bodied joystick with four positions (up, down, left, right) that springs back to centre when released. Each axis has its own normally open contacts (2NO+2NO), so one operator can give jog or direction commands on two axes, for example hoist up\/down and travel left\/right, or forward\/reverse on two drives. The die-cast, chromate-plated body is built for machine-mounted and harsh-environment control stations.\u003c\/p\u003e\u003cp\u003eFor enclosed panels the lower-cost plastic \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-cp101dj21-ip65-joystick-spring-return-4-positions-2-n-o-2-n-o\"\u003eEMAS CP707DJ41\u003c\/a\u003e has the same 4-way action. Need just one axis? See the 2-position metal \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-cm101dj21-ip65-metal-body-joystick-switch-spring-return-2-positions\"\u003eEMAS CM101DJ21\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN CM707DJ41\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4 positions\u003c\/strong\u003e, spring return to the centre (off) position\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2NO + 2NO\u003c\/strong\u003e contacts, one pair per axis, 4A at 230V AC (AC15)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDie-cast metal body\u003c\/strong\u003e, corrosion-resistant chromate plating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIP65\u003c\/strong\u003e front of panel, standard 22mm cut-out\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/EMAS-CM707DJ41-Datasheet.pdf\" title=\"EMAS CM707DJ41 Datasheet Download\"\u003eEMAS CM707DJ41 Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eTechnical Details\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eJoystick control unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpring return, 4 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContacts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2NO+2NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMounting Diameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e22 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4A (230V AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUsage Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAC15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e500,000 operations (min.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100,000 operations (min.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 \/ +65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eContact Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAgNi\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5-2.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60947-5-1, UL 508, VDE 0660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCM Series Metal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eHow are the contacts arranged?\u003c\/strong\u003e\u003cbr\u003eEach axis operates its own normally open contacts: pushing the lever one way closes one contact, the opposite direction closes the other. Releasing the lever returns it to centre and all contacts open.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it drive a motor directly?\u003c\/strong\u003e\u003cbr\u003eNo. The contacts are control-rated (4A AC15) and should switch contactor coils, relay inputs or PLC\/inverter digital inputs, not the motor current itself.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it control a variable speed drive?\u003c\/strong\u003e\u003cbr\u003eYes. Wire the contacts to the inverter's forward\/reverse or preset-speed digital inputs to jog a motor in either direction.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMetal or plastic: which should I choose?\u003c\/strong\u003e\u003cbr\u003eChoose the metal CM707DJ41 for pendant stations, crane and hoist controls or exposed machines. The plastic CP707DJ41 suits enclosed control panels.\u003c\/p\u003e\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHoists \u0026amp; light cranes\u003c\/strong\u003e — up\/down and travel control from one lever\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine positioning\u003c\/strong\u003e — two-axis jog control for tables, gantries and manipulators\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAgricultural \u0026amp; mobile equipment\u003c\/strong\u003e — rugged direction control on exposed operator stations\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTroubleshooting \u0026amp; Guides\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/inverter-drive-setup\"\u003eAG Inverter Drive Control\u003c\/a\u003e — wiring switches to inverter digital inputs\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/faultfinding\"\u003eFaultfinding\u003c\/a\u003e — tracing control circuit faults\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/knowledge-base\"\u003eKnowledge Base\u003c\/a\u003e — all our technical guides in one place\u003c\/li\u003e\n\u003c\/ul\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How are the contacts arranged?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Each axis operates its own normally open contacts: pushing the lever one way closes one contact, the opposite direction closes the other. Releasing the lever returns it to centre and all contacts open.\"}},{\"@type\":\"Question\",\"name\":\"Can it drive a motor directly?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The contacts are control-rated (4A AC15) and should switch contactor coils, relay inputs or PLC\/inverter digital inputs, not the motor current itself.\"}},{\"@type\":\"Question\",\"name\":\"Can it control a variable speed drive?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Wire the contacts to the inverter's forward\/reverse or preset-speed digital inputs to jog a motor in either direction.\"}},{\"@type\":\"Question\",\"name\":\"Metal or plastic: which should I choose?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Choose the metal CM707DJ41 for pendant stations, crane and hoist controls or exposed machines. The plastic CP707DJ41 suits enclosed control panels.\"}}]}\u003c\/script\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57783559750005,"sku":"CM707DJ41","price":27.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/CM707DJ41.jpg?v=1794824848","url":"https:\/\/www.production-automation.co.uk\/products\/emas-cm707dj41-metal-body-joystick-spring-return-4-positions","provider":"Production Automation","version":"1.0","type":"link"}