{"product_id":"emas-mks1tm-1-6-mks-series-1-00-1-60a-motor-protection-switch","title":"EMAS MKS1TM-1.6 - MKS Series 1.00-1.60A Motor Protection Switch","description":"\u003ch2\u003e\u003cstrong\u003eOverload, Short-Circuit And Phase-Loss Protection For 1.00-1.60A Motors\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEMAS MKS1TM-1.6\u003c\/strong\u003e is a DIN rail manual motor protection switch (MPCB) for motors with a full load current between 1.00A and 1.60A, a range that covers many small three-phase pumps, fans and gear motors. One compact device gives you adjustable thermal overload, fixed magnetic short-circuit and phase-loss protection, plus a local means of isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMPN MKS1TM-1.6\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable thermal overload\u003c\/strong\u003e - set the dial to the motor's nameplate current anywhere from 1.00A to 1.60A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed magnetic trip at 12 x Ie\u003c\/strong\u003e - clears short circuits instantly, with a breaking capacity of at least 6kA at 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase deficiency protection\u003c\/strong\u003e - trips if a 3-phase motor loses a phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature compensated\u003c\/strong\u003e - the trip point stays consistent as panel temperature changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eThermic Current Calibration\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.00-1.60A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e25A (switch rating)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eTS EN 60947-4-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperational Frequency\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e50-60Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eUsage Category\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eAC-3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eFixed at 12 x Ie, min. 6kA \/ 400V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e690V AC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e6kV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMechanical \/ Electrical Life\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e100,000 \/ 100,000 operations (min.)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e360 operations\/hour\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eIP40\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e-5°C to +40°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e0.75-4mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.8Nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e35mm DIN rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from a normal MCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects the cable with a fixed trip curve. The MKS1TM-1.6 protects the motor itself: its thermal trip is set to the motor's running current, it rides through starting inrush, and it adds phase-loss protection that an MCB does not have.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose and set the right range?\u003c\/strong\u003e\u003cbr\u003eRead the full load current from the motor nameplate. If it falls between 1.00A and 1.60A, this is the right switch; set the dial to that value. Below 1.00A use the MKS1TM-1; from 1.60A to 2.50A use the MKS1TM-2.5.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be mounted outside a panel?\u003c\/strong\u003e\u003cbr\u003eNo. The switch is rated IP40, so it should be fitted on 35mm DIN rail inside an enclosure. EMAS also make an enclosed MKS1TMK version for surface mounting; ask us if you need one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable sizes does it accept?\u003c\/strong\u003e\u003cbr\u003eThe terminals take 0.75mm² to 4mm² conductors, tightened to 1.8Nm. Auxiliary contacts and other MKS accessories are sold separately.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePumps and circulators\u003c\/strong\u003e - overload and single-phasing protection for small direct-on-line pump motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation fans\u003c\/strong\u003e - a combined isolator and motor protector for extract and supply fan motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGear motors and conveyors\u003c\/strong\u003e - compact protection for small drives in machine-builder and OEM panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed a different range? See the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-1-mks-series-0-63-1-00a-motor-protection-switch\" style=\"color: rgb(43, 0, 255);\"\u003eEMAS MKS1TM-1 (0.63-1.00A)\u003c\/a\u003e\u003c\/strong\u003e or the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-4-mks-series-2-50-4-00a-motor-protection-switch\" style=\"color: rgb(43, 0, 255);\"\u003eEMAS MKS1TM-4 (2.50-4.00A)\u003c\/a\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How is this different from a normal MCB?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"An MCB protects the cable with a fixed trip curve. The MKS1TM-1.6 protects the motor itself: its thermal trip is set to the motor's running current, it rides through starting inrush, and it adds phase-loss protection that an MCB does not have.\"}},{\"@type\":\"Question\",\"name\":\"How do I choose and set the right range?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Read the full load current from the motor nameplate. If it falls between 1.00A and 1.60A, this is the right switch; set the dial to that value. Below 1.00A use the MKS1TM-1; from 1.60A to 2.50A use the MKS1TM-2.5.\"}},{\"@type\":\"Question\",\"name\":\"Can it be mounted outside a panel?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The switch is rated IP40, so it should be fitted on 35mm DIN rail inside an enclosure. EMAS also make an enclosed MKS1TMK version for surface mounting; ask us if you need one.\"}},{\"@type\":\"Question\",\"name\":\"What cable sizes does it accept?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The terminals take 0.75mm² to 4mm² conductors, tightened to 1.8Nm. Auxiliary contacts and other MKS accessories are sold separately.\"}}]}\n\u003c\/script\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57710365704565,"sku":"MKS1TM-1.6","price":61.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/MKS1TM-1_6_20_281_29.jpg?v=1793596959","url":"https:\/\/www.production-automation.co.uk\/fr\/products\/emas-mks1tm-1-6-mks-series-1-00-1-60a-motor-protection-switch","provider":"Production Automation","version":"1.0","type":"link"}