{"product_id":"emas-hn1710nue-contactor-3p-17a-7-5kw-230v-coil-1-n-o-aux","title":"EMAS HN1710NUE - Contactor 3P 17A 7.5KW \/ 30A Heating (230V AC Coil 1 N.O. Aux)","description":"\u003ch2\u003e\u003cstrong\u003e17A 3-Pole Contactor With 230V AC Coil And 1 N.O. Auxiliary\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eEMAS HN1710NUE\u003c\/strong\u003e is a 3 pole HN series contactor with a 230V AC coil and one normally open (N.O.) auxiliary contact, for DIN rail or panel mounting. It switches three-phase motors up to 7.5kW at 400V (17A AC3) and resistive heating loads up to 30A (AC1). The built-in N.O. auxiliary is ideal for a run or feedback signal back to a PLC or indicator.\u003c\/p\u003e\u003cp\u003eA common replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Other HN sizes: \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn0910nue-contactor-9a-4kw-230v-coil-1-n-o-aux\"\u003e9A\u003c\/a\u003e, \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn1310nue-contactor-3p-13a-6kw-230v-coil-1-n-o-aux\"\u003e13A\u003c\/a\u003e, \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn1710nue-contactor-3p-17a-7-5kw-230v-coil-1-n-o-aux\"\u003e17A\u003c\/a\u003e and \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn2510nue-contactor-3p-25a-11kw-40a-heating-230v-coil-1-n-o-aux\"\u003e25A\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN HN1710NUE\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e17A AC3 \/ 7.5kW\u003c\/strong\u003e motor rating at 380-415V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30A AC1\u003c\/strong\u003e thermal rating for heaters and resistive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e230V AC coil\u003c\/strong\u003e, 50-60Hz, runs directly from UK mains control circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary\u003c\/strong\u003e: 1 N.O. built in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 million\u003c\/strong\u003e mechanical operations, 1 million electrical (EMAS data)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/EMAS-HN1710NUE-Datasheet.pdf\" title=\"EMAS HN1710NUE Datasheet Download\"\u003eEMAS HN1710NUE Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eTechnical Details\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17A (AC3), 30A (AC1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5kW at 380-415V, 4kW at 220-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220-230V AC 50-60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Frequency (On-Off\/Hour)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMech. 1800, Elec. 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1890V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MΩ (500V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 \/ +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTS EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHN Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the difference between AC1 and AC3 ratings?\u003c\/strong\u003e\u003cbr\u003eAC1 applies to resistive loads such as heating elements and gives the higher rating (30A). AC3 applies to inductive loads such as three-phase motors and is lower (17A \/ 7.5kW at 400V) because motor inrush current is harder on the contacts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill the 230V coil work on UK 240V mains?\u003c\/strong\u003e\u003cbr\u003eYes. UK mains is nominally 230V, often measured at around 240V, which is within the coil's normal operating tolerance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs there a version with the other auxiliary contact?\u003c\/strong\u003e\u003cbr\u003eYes. The \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn1701nue-contactor-3p-17a-7-5kw-230v-coil-1-n-c-aux\"\u003eHN1701NUE\u003c\/a\u003e is the 1 N.C. auxiliary version of this contactor. Use N.O. for a run or feedback signal and N.C. for interlocking or fault indication.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this replace my existing branded contactor?\u003c\/strong\u003e\u003cbr\u003eLikely yes. It is a common form-factor replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Check that the coil voltage, load rating and auxiliary contacts match before ordering.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be used outdoors or in a washdown area?\u003c\/strong\u003e\u003cbr\u003eNo. It is IP20 and must be mounted inside an enclosed control panel.\u003c\/p\u003e\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvens, kilns \u0026amp; heaters\u003c\/strong\u003e — switching heating elements up to 30A from a temperature controller relay or SSR output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor control panels\u003c\/strong\u003e — starters for pumps, fans, compressors and conveyors up to 7.5kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel refurbishment\u003c\/strong\u003e — drop-in replacement for ageing or discontinued branded contactors\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTroubleshooting \u0026amp; Guides\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/kiln-temperature-control\"\u003eKiln Temperature Control\u003c\/a\u003e — how contactors fit into a kiln control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/kiln-controller-upgrade-parts\"\u003eKiln Controller Upgrade Parts\u003c\/a\u003e — choosing the controller, SSR or contactor for an upgrade\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/faultfinding\"\u003eFaultfinding\u003c\/a\u003e — diagnosing a contactor that will not pull in or chatters\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/knowledge-base\"\u003eKnowledge Base\u003c\/a\u003e — all our technical guides in one place\u003c\/li\u003e\n\u003c\/ul\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the difference between AC1 and AC3 ratings?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"AC1 applies to resistive loads such as heating elements and gives the higher rating (30A). AC3 applies to inductive loads such as three-phase motors and is lower (17A \/ 7.5kW at 400V) because motor inrush current is harder on the contacts.\"}}, {\"@type\": \"Question\", \"name\": \"Will the 230V coil work on UK 240V mains?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. UK mains is nominally 230V, often measured at around 240V, which is within the coil's normal operating tolerance.\"}}, {\"@type\": \"Question\", \"name\": \"Is there a version with the other auxiliary contact?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The HN1701NUE is the 1 N.C. auxiliary version of this contactor. Use N.O. for a run or feedback signal and N.C. for interlocking or fault indication.\"}}, {\"@type\": \"Question\", \"name\": \"Can this replace my existing branded contactor?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Likely yes. It is a common form-factor replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Check that the coil voltage, load rating and auxiliary contacts match before ordering.\"}}, {\"@type\": \"Question\", \"name\": \"Can it be used outdoors or in a washdown area?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. It is IP20 and must be mounted inside an enclosed control panel.\"}}]}\u003c\/script\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57762740896117,"sku":"HN1710NUE","price":40.66,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/HN0910NUE_2.png?v=1662395774","url":"https:\/\/www.production-automation.co.uk\/fr\/products\/emas-hn1710nue-contactor-3p-17a-7-5kw-230v-coil-1-n-o-aux","provider":"Production Automation","version":"1.0","type":"link"}