{"title":"Contactors \u0026 Accessories","description":"\u003cp\u003eEMAS HN series 3-pole contactors with 230V AC coils, from 9A to 25A (AC3), with N.O. or N.C. auxiliary contacts. A cost-effective replacement for Schneider, ABB and Crompton contactors in heating, kiln and motor control panels. See also \u003ca href=\"\/fr\/collections\/motor-control\"\u003eMotor Control\u003c\/a\u003e and \u003ca href=\"\/fr\/collections\/solid-state-relays\"\u003eSolid State Relays\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"emas-hn0910nue-contactor-9a-4kw-230v-coil-1-n-o-aux","title":"Contacteur EMAS HN Chauffage ou commande moteur 3 pôles bobine 230 V (1 N.O. Aux)","description":"\u003ch3\u003eContacteur série HN EMAS\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003eContacteur compact pour rail DIN ou montage sur panneau d'EMAS. Un contacteur fiable à une fraction du prix des grandes marques. Veuillez sélectionner la taille requise dans la liste déroulante. 3 pôles et 1 contact auxiliaire normalement ouvert.\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003eClasse AC1 - charges résistives, c'est-à-dire éléments chauffants. Les classes AC1 sont toujours plus élevées.\u003cbr\u003e\nClasse AC3 - charges inductives, c'est-à-dire moteurs triphasés. Les classes AC3 sont toujours plus faibles.\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003eRemplace Crompton, Schneider, Telemecanique, ABB et plus encore. Des surcharges, des blocs de contacts auxiliaires et d'autres types de bobines sont disponibles sur demande.\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eFréquence de fonctionnement\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e50 - 60 Hz\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProduit\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003eContacteur\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCourant (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e9A-25A\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCatégorie d'utilisation\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003eAC 3\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eDurée de vie mécanique (Qté min)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e10000000\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eDurée de vie électrique (Qté min)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e1000000\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eFréquence de fonctionnement (Marche-Arrêt\/Heure)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003eMéc. 1800 Élec. 600\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eTension d'isolation (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e690V CA\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eTension de tenue aux chocs (Uimp)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e6 kV\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRigidité diélectrique (Corps-Contact)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e1890V CA\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRigidité diélectrique (Contact-Contact)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e1890V CA\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRésistance d'isolement\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e10 MΩ (500 V CC)\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eTempérature de fonctionnement\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e-15 \/ +80 °C\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eDegré de pollution\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e3\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eDegré de protection\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003eIP20\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eSection de câble\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e1,5 mm²\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCouple de serrage des vis\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e1,8 Nm\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003ePouvoir de coupure en court-circuit (Ics)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e50 kA\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eSérie\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003eSérie HN\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eTension\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e220-230V\/50-60HZ\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eAuxiliaire\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e1NO\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch3\u003eQuestions fréquemment posées\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuelle est la différence entre les classes AC1 et AC3 ?\u003c\/strong\u003e\u003cbr\u003e\nL'AC1 s'applique aux charges résistives (comme les éléments chauffants) et offre un courant nominal plus élevé. L'AC3 s'applique aux charges inductives (comme les moteurs triphasés) et a toujours un courant nominal plus faible, car le courant d'appel du moteur est plus exigeant pour les contacts. Vérifiez quelle classe correspond à votre type de charge avant de dimensionner.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCe contacteur peut-il remplacer mon contacteur de marque existant ?\u003c\/strong\u003e\u003cbr\u003e\nTrès probablement oui — il s'agit d'un remplacement courant de format pour les contacteurs de marque Crompton, Schneider, Telemecanique, ABB et similaires. Confirmez que votre tension de bobine et la configuration pôle\/auxiliaire correspondent avant de commander.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEst-il classé IP65 comme les commutateurs de la série CP ?\u003c\/strong\u003e\u003cbr\u003e\nNon — les contacteurs sont classés IP20, destinés à être montés à l'intérieur d'un tableau de commande fermé plutôt qu'à une exposition directe à l'extérieur ou au lavage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePuis-je ajouter des surcharges ou des contacts auxiliaires supplémentaires ?\u003c\/strong\u003e\u003cbr\u003e\nOui — des surcharges, des blocs de contacts auxiliaires supplémentaires et d'autres options de tension de bobine sont disponibles sur demande.\u003c\/p\u003e\n\n\u003ch3\u003eApplications industrielles\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eChauffage et contrôle de processus\u003c\/strong\u003e — commutation d'éléments chauffants et de charges résistives (classe AC1)\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eTableaux de commande moteur\u003c\/strong\u003e — démarreurs de moteurs triphasés pour pompes, ventilateurs et moteurs industriels généraux (classe AC3)\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eRénovation de tableaux\u003c\/strong\u003e — remplacement direct des contacteurs de marque vieillissants ou abandonnés\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":45585023467690,"sku":"HN0910NUE","price":30.19,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/HN0910NUE_2.png?v=1662395774"},{"product_id":"emas-hn0901nue-contactor-3p-9a-4kw-20a-heating-230v-coil-1-n-c-aux","title":"Contacteur EMAS HN0901NUE 3P 9A 4KW \/ 20A Chauffage (Bobine 230V 1 Aux NC)","description":"\u003ch3\u003eContacteur série HN 9A 220-230V\/50-60HZ\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003eContacteur compact de chez EMAS, à monter sur rail DIN ou sur panneau. 3 pôles et 1 contact auxiliaire normalement fermé. Couramment utilisé pour la commutation de charges de chauffage, de moteur ou d'éclairage. Convient pour les charges thermiques jusqu'à 20A.\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eFréquence de fonctionnement\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e50 - 60Hz\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProduit\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003eContacteur\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCourant (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e9A\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCatégorie d'utilisation\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003eAC 3\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eDurée de vie mécanique (Qté Min)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e10000000\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eDurée de vie électrique (Qté Min)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e1000000\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eFréquence de fonctionnement (Marche-Arrêt\/Heure)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003eMéc. 1800 Élec. 600\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eTension d'isolation (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e690V AC\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eTension de tenue aux chocs (Uimp)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e6 kV\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRigidité diélectrique (Corps-Contact)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e1890V AC\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRigidité diélectrique (Contact-Contact)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e1890V AC\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRésistance d'isolement\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e10 MΩ (500 V CC)\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eTempérature de fonctionnement\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e-15 \/ +80 °C\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eDegré de pollution\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e3\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eDegré de protection\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003eIP20\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eSection de câble\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e1,5 mm²\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCouple de serrage\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e1,8 Nm\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003ePouvoir de coupure de court-circuit (Ics)\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e50 kA\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eSérie\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003eSérie HN\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eTension\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e220-230V\/50-60HZ\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eAuxiliaire\u003c\/strong\u003e\u003c\/div\u003e\n\n\u003cdiv class=\"col-xs-6\"\u003e1NF\u003c\/div\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch3\u003eFoire aux questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQuelle est la différence entre cette version et la version auxiliaire 1NO ?\u003c\/strong\u003e\u003cbr\u003e\nCette variante dispose d'un contact auxiliaire normalement fermé (N.F.), utile pour la signalisation de défaut\/état qui doit s'ouvrir lorsque le contacteur est sous tension. Si vous avez besoin d'un auxiliaire normalement ouvert pour un signal de démarrage\/marche, EMAS propose également la version 1NO de ce contacteur.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e9A est-il suffisant pour ma charge de moteur ou de chauffage ?\u003c\/strong\u003e\u003cbr\u003e\n9A\/4KW est conçu pour les charges moteur ; pour les charges de chauffage résistives, la valeur thermique AC1 monte jusqu'à 20A. Vérifiez le courant nominal de la charge par rapport à ces valeurs avant de sélectionner.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCe produit peut-il remplacer mon contacteur de marque existant ?\u003c\/strong\u003e\u003cbr\u003e\nProbablement oui — il s'agit d'un remplacement de format courant pour les grandes marques de contacteurs. Vérifiez que votre tension de bobine et la configuration de pôle\/auxiliaire correspondent avant de commander.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConvient-il pour un panneau de lavage ou extérieur ?\u003c\/strong\u003e\u003cbr\u003e\nNon — classé IP20, il est destiné à être monté à l'intérieur d'un tableau de commande fermé plutôt qu'à une exposition directe.\u003c\/p\u003e\n\n\u003ch3\u003eApplications industrielles\u003c\/h3\u003e\n\u003cul\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eChauffage et contrôle de processus\u003c\/strong\u003e — commutation d'éléments chauffants et de charges résistives jusqu'à 20A\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eTableaux de commande moteur\u003c\/strong\u003e — démarreur moteur 9A\/4KW pour pompes, ventilateurs et petits moteurs industriels\u003c\/li\u003e\n\n\u003cli\u003e\n\n\u003cstrong\u003eCommande d'éclairage\u003c\/strong\u003e — commutation de contacteur pour de grandes charges d'éclairage dans les bâtiments commerciaux ou industriels\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":43585252786346,"sku":"HN0901NUE","price":30.19,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/HN0910NUE_2_d1fbab11-2baa-4be5-9ff7-9c36b411b39f.png?v=1665174566"},{"product_id":"emas-hn2510nue-contactor-3p-25a-11kw-40a-heating-230v-coil-1-n-o-aux","title":"EMAS HN2510NUE - Contactor 3P 25A 11KW \/ 40A Heating (230V AC Coil 1 N.O. Aux)","description":"\u003cp\u003eThe \u003cstrong\u003eEMAS HN2510NUE\u003c\/strong\u003e is a 3 pole contactor with a 230V AC coil and one normally open auxiliary contact, for DIN rail or panel mounting. It switches three-phase motors up to 11kW (25A AC3) and resistive heating loads up to 40A (AC1), making it a cost-effective choice for larger heaters, ovens and pump motors.\u003c\/p\u003e\n\u003cp\u003eIt is a common replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Overloads, auxiliary contact blocks and other coil voltages are available on request. For smaller loads, see the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn0910nue-contactor-9a-4kw-230v-coil-1-n-o-aux\" style=\"color: #0000ff; font-weight:bold;\"\u003eEMAS HN0910NUE 9A contactor\u003c\/a\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eContactor\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCurrent (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e25A (AC3), 40A (AC1)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMotor Rating\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e11kW (AC3)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eAuxiliary\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1NO\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e220-230V AC 50-60Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMechanical Life (Min Qty)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e10000000\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eElectrical Life (Min Qty)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1000000\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Frequency (On-Off\/Hour)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eMech. 1800 Elec. 600\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e690V AC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e6 kV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1890V AC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eIsolation Resistance\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e10 MΩ (500 V DC)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e-15 \/ +80 °C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eIP20\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eShort Circuit Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e50 kA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eSerial\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eHN Series\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the difference between AC1 and AC3 ratings?\u003c\/strong\u003e\u003cbr\u003eAC1 applies to resistive loads such as heating elements and gives the higher rating (40A). AC3 applies to inductive loads such as three-phase motors and is lower (25A \/ 11kW) because motor inrush current is harder on the contacts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill the 230V coil work on UK 240V mains?\u003c\/strong\u003e\u003cbr\u003eYes. UK mains is nominally 230V, often measured at around 240V, which is within the coil's normal operating tolerance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this replace my existing branded contactor?\u003c\/strong\u003e\u003cbr\u003eLikely yes. It is a common form-factor replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Check that the coil voltage, load rating and auxiliary contact match before ordering.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the 9A version enough for my load?\u003c\/strong\u003e\u003cbr\u003eThe \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn0910nue-contactor-9a-4kw-230v-coil-1-n-o-aux\" style=\"color: #0000ff; font-weight:bold;\"\u003eHN0910NUE\u003c\/a\u003e\u003c\/strong\u003e covers motors up to 4kW and heating up to 20A. Above that, this 25A model is the right choice.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvens, kilns \u0026amp; heaters\u003c\/strong\u003e — switching heating loads up to 40A from a temperature controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor control panels\u003c\/strong\u003e — starters for pumps, compressors and fans up to 11kW.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel refurbishment\u003c\/strong\u003e — drop-in replacement for ageing or discontinued branded contactors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What is the difference between AC1 and AC3 ratings?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"AC1 applies to resistive loads such as heating elements and gives the higher rating (40A). AC3 applies to inductive loads such as three-phase motors and is lower (25A \/ 11kW) because motor inrush current is harder on the contacts.\"}},{\"@type\":\"Question\",\"name\":\"Will the 230V coil work on UK 240V mains?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. UK mains is nominally 230V, often measured at around 240V, which is within the coil's normal operating tolerance.\"}},{\"@type\":\"Question\",\"name\":\"Can this replace my existing branded contactor?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Likely yes. It is a common form-factor replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Check that the coil voltage, load rating and auxiliary contact match before ordering.\"}},{\"@type\":\"Question\",\"name\":\"Is the 9A version enough for my load?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The HN0910NUE covers motors up to 4kW and heating up to 20A. Above that, this 25A model is the right choice.\"}}]}\n\u003c\/script\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57641769632117,"sku":"HN2510NUE","price":52.08,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/HN0910NUE_2.png?v=1662395774"},{"product_id":"emas-hn1310nue-contactor-3p-13a-6kw-230v-coil-1-n-o-aux","title":"EMAS HN1310NUE - Contactor 3P 13A 6KW \/ 20A Heating (230V AC Coil 1 N.O. Aux)","description":"\u003ch2\u003e\u003cstrong\u003e13A 3-Pole Contactor With 230V AC Coil And 1 N.O. Auxiliary\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eEMAS HN1310NUE\u003c\/strong\u003e is a 3 pole HN series contactor with a 230V AC coil and one normally open (N.O.) auxiliary contact, for DIN rail or panel mounting. It switches three-phase motors up to 6kW at 400V (13A AC3) and resistive heating loads up to 20A (AC1). The built-in N.O. auxiliary is ideal for a run or feedback signal back to a PLC or indicator.\u003c\/p\u003e\u003cp\u003eA common replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Other HN sizes: \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn0910nue-contactor-9a-4kw-230v-coil-1-n-o-aux\"\u003e9A\u003c\/a\u003e, \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn1310nue-contactor-3p-13a-6kw-230v-coil-1-n-o-aux\"\u003e13A\u003c\/a\u003e, \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn1710nue-contactor-3p-17a-7-5kw-230v-coil-1-n-o-aux\"\u003e17A\u003c\/a\u003e and \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn2510nue-contactor-3p-25a-11kw-40a-heating-230v-coil-1-n-o-aux\"\u003e25A\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN HN1310NUE\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e13A AC3 \/ 6kW\u003c\/strong\u003e motor rating at 380-415V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20A AC1\u003c\/strong\u003e thermal rating for heaters and resistive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e230V AC coil\u003c\/strong\u003e, 50-60Hz, runs directly from UK mains control circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary\u003c\/strong\u003e: 1 N.O. built in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 million\u003c\/strong\u003e mechanical operations, 1 million electrical (EMAS data)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/EMAS-HN1310NUE-Datasheet.pdf\" title=\"EMAS HN1310NUE Datasheet Download\"\u003eEMAS HN1310NUE Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eTechnical Details\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13A (AC3), 20A (AC1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6kW at 380-415V, 3.2kW at 220-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220-230V AC 50-60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Frequency (On-Off\/Hour)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMech. 1800, Elec. 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1890V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MΩ (500V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 \/ +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTS EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHN Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the difference between AC1 and AC3 ratings?\u003c\/strong\u003e\u003cbr\u003eAC1 applies to resistive loads such as heating elements and gives the higher rating (20A). AC3 applies to inductive loads such as three-phase motors and is lower (13A \/ 6kW at 400V) because motor inrush current is harder on the contacts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill the 230V coil work on UK 240V mains?\u003c\/strong\u003e\u003cbr\u003eYes. UK mains is nominally 230V, often measured at around 240V, which is within the coil's normal operating tolerance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs there a version with the other auxiliary contact?\u003c\/strong\u003e\u003cbr\u003eYes. The \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn1301nue-contactor-3p-13a-6kw-230v-coil-1-n-c-aux\"\u003eHN1301NUE\u003c\/a\u003e is the 1 N.C. auxiliary version of this contactor. Use N.O. for a run or feedback signal and N.C. for interlocking or fault indication.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this replace my existing branded contactor?\u003c\/strong\u003e\u003cbr\u003eLikely yes. It is a common form-factor replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Check that the coil voltage, load rating and auxiliary contacts match before ordering.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be used outdoors or in a washdown area?\u003c\/strong\u003e\u003cbr\u003eNo. It is IP20 and must be mounted inside an enclosed control panel.\u003c\/p\u003e\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvens, kilns \u0026amp; heaters\u003c\/strong\u003e — switching heating elements up to 20A from a temperature controller relay or SSR output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor control panels\u003c\/strong\u003e — starters for pumps, fans, compressors and conveyors up to 6kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel refurbishment\u003c\/strong\u003e — drop-in replacement for ageing or discontinued branded contactors\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTroubleshooting \u0026amp; Guides\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/kiln-temperature-control\"\u003eKiln Temperature Control\u003c\/a\u003e — how contactors fit into a kiln control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/kiln-controller-upgrade-parts\"\u003eKiln Controller Upgrade Parts\u003c\/a\u003e — choosing the controller, SSR or contactor for an upgrade\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/faultfinding\"\u003eFaultfinding\u003c\/a\u003e — diagnosing a contactor that will not pull in or chatters\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/knowledge-base\"\u003eKnowledge Base\u003c\/a\u003e — all our technical guides in one place\u003c\/li\u003e\n\u003c\/ul\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the difference between AC1 and AC3 ratings?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"AC1 applies to resistive loads such as heating elements and gives the higher rating (20A). AC3 applies to inductive loads such as three-phase motors and is lower (13A \/ 6kW at 400V) because motor inrush current is harder on the contacts.\"}}, {\"@type\": \"Question\", \"name\": \"Will the 230V coil work on UK 240V mains?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. UK mains is nominally 230V, often measured at around 240V, which is within the coil's normal operating tolerance.\"}}, {\"@type\": \"Question\", \"name\": \"Is there a version with the other auxiliary contact?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The HN1301NUE is the 1 N.C. auxiliary version of this contactor. Use N.O. for a run or feedback signal and N.C. for interlocking or fault indication.\"}}, {\"@type\": \"Question\", \"name\": \"Can this replace my existing branded contactor?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Likely yes. It is a common form-factor replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Check that the coil voltage, load rating and auxiliary contacts match before ordering.\"}}, {\"@type\": \"Question\", \"name\": \"Can it be used outdoors or in a washdown area?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. It is IP20 and must be mounted inside an enclosed control panel.\"}}]}\u003c\/script\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57762740502901,"sku":"HN1310NUE","price":32.87,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/HN0910NUE_2.png?v=1662395774"},{"product_id":"emas-hn1301nue-contactor-3p-13a-6kw-230v-coil-1-n-c-aux","title":"EMAS HN1301NUE - Contactor 3P 13A 6KW \/ 20A Heating (230V AC Coil 1 N.C. Aux)","description":"\u003ch2\u003e\u003cstrong\u003e13A 3-Pole Contactor With 230V AC Coil And 1 N.C. Auxiliary\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eEMAS HN1301NUE\u003c\/strong\u003e is a 3 pole HN series contactor with a 230V AC coil and one normally closed (N.C.) auxiliary contact, for DIN rail or panel mounting. It switches three-phase motors up to 6kW at 400V (13A AC3) and resistive heating loads up to 20A (AC1). The built-in N.C. auxiliary is ideal for interlocking or fault indication, opening as the contactor pulls in.\u003c\/p\u003e\u003cp\u003eA common replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Other HN sizes: \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn0910nue-contactor-9a-4kw-230v-coil-1-n-o-aux\"\u003e9A\u003c\/a\u003e, \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn1310nue-contactor-3p-13a-6kw-230v-coil-1-n-o-aux\"\u003e13A\u003c\/a\u003e, \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn1710nue-contactor-3p-17a-7-5kw-230v-coil-1-n-o-aux\"\u003e17A\u003c\/a\u003e and \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn2510nue-contactor-3p-25a-11kw-40a-heating-230v-coil-1-n-o-aux\"\u003e25A\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN HN1301NUE\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e13A AC3 \/ 6kW\u003c\/strong\u003e motor rating at 380-415V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e20A AC1\u003c\/strong\u003e thermal rating for heaters and resistive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e230V AC coil\u003c\/strong\u003e, 50-60Hz, runs directly from UK mains control circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary\u003c\/strong\u003e: 1 N.C. built in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 million\u003c\/strong\u003e mechanical operations, 1 million electrical (EMAS data)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/EMAS-HN1301NUE-Datasheet.pdf\" title=\"EMAS HN1301NUE Datasheet Download\"\u003eEMAS HN1301NUE Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eTechnical Details\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13A (AC3), 20A (AC1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6kW at 380-415V, 3.2kW at 220-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220-230V AC 50-60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Frequency (On-Off\/Hour)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMech. 1800, Elec. 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1890V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MΩ (500V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 \/ +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTS EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHN Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the difference between AC1 and AC3 ratings?\u003c\/strong\u003e\u003cbr\u003eAC1 applies to resistive loads such as heating elements and gives the higher rating (20A). AC3 applies to inductive loads such as three-phase motors and is lower (13A \/ 6kW at 400V) because motor inrush current is harder on the contacts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill the 230V coil work on UK 240V mains?\u003c\/strong\u003e\u003cbr\u003eYes. UK mains is nominally 230V, often measured at around 240V, which is within the coil's normal operating tolerance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs there a version with the other auxiliary contact?\u003c\/strong\u003e\u003cbr\u003eYes. The \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn1310nue-contactor-3p-13a-6kw-230v-coil-1-n-o-aux\"\u003eHN1310NUE\u003c\/a\u003e is the 1 N.O. auxiliary version of this contactor. Use N.O. for a run or feedback signal and N.C. for interlocking or fault indication.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this replace my existing branded contactor?\u003c\/strong\u003e\u003cbr\u003eLikely yes. It is a common form-factor replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Check that the coil voltage, load rating and auxiliary contacts match before ordering.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be used outdoors or in a washdown area?\u003c\/strong\u003e\u003cbr\u003eNo. It is IP20 and must be mounted inside an enclosed control panel.\u003c\/p\u003e\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvens, kilns \u0026amp; heaters\u003c\/strong\u003e — switching heating elements up to 20A from a temperature controller relay or SSR output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor control panels\u003c\/strong\u003e — starters for pumps, fans, compressors and conveyors up to 6kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel refurbishment\u003c\/strong\u003e — drop-in replacement for ageing or discontinued branded contactors\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTroubleshooting \u0026amp; Guides\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/kiln-temperature-control\"\u003eKiln Temperature Control\u003c\/a\u003e — how contactors fit into a kiln control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/kiln-controller-upgrade-parts\"\u003eKiln Controller Upgrade Parts\u003c\/a\u003e — choosing the controller, SSR or contactor for an upgrade\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/faultfinding\"\u003eFaultfinding\u003c\/a\u003e — diagnosing a contactor that will not pull in or chatters\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/knowledge-base\"\u003eKnowledge Base\u003c\/a\u003e — all our technical guides in one place\u003c\/li\u003e\n\u003c\/ul\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the difference between AC1 and AC3 ratings?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"AC1 applies to resistive loads such as heating elements and gives the higher rating (20A). AC3 applies to inductive loads such as three-phase motors and is lower (13A \/ 6kW at 400V) because motor inrush current is harder on the contacts.\"}}, {\"@type\": \"Question\", \"name\": \"Will the 230V coil work on UK 240V mains?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. UK mains is nominally 230V, often measured at around 240V, which is within the coil's normal operating tolerance.\"}}, {\"@type\": \"Question\", \"name\": \"Is there a version with the other auxiliary contact?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The HN1310NUE is the 1 N.O. auxiliary version of this contactor. Use N.O. for a run or feedback signal and N.C. for interlocking or fault indication.\"}}, {\"@type\": \"Question\", \"name\": \"Can this replace my existing branded contactor?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Likely yes. It is a common form-factor replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Check that the coil voltage, load rating and auxiliary contacts match before ordering.\"}}, {\"@type\": \"Question\", \"name\": \"Can it be used outdoors or in a washdown area?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. It is IP20 and must be mounted inside an enclosed control panel.\"}}]}\u003c\/script\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57762740666741,"sku":"HN1301NUE","price":32.87,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/HN0910NUE_2.png?v=1662395774"},{"product_id":"emas-hn1710nue-contactor-3p-17a-7-5kw-230v-coil-1-n-o-aux","title":"EMAS HN1710NUE - Contactor 3P 17A 7.5KW \/ 30A Heating (230V AC Coil 1 N.O. Aux)","description":"\u003ch2\u003e\u003cstrong\u003e17A 3-Pole Contactor With 230V AC Coil And 1 N.O. Auxiliary\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eEMAS HN1710NUE\u003c\/strong\u003e is a 3 pole HN series contactor with a 230V AC coil and one normally open (N.O.) auxiliary contact, for DIN rail or panel mounting. It switches three-phase motors up to 7.5kW at 400V (17A AC3) and resistive heating loads up to 30A (AC1). The built-in N.O. auxiliary is ideal for a run or feedback signal back to a PLC or indicator.\u003c\/p\u003e\u003cp\u003eA common replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Other HN sizes: \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn0910nue-contactor-9a-4kw-230v-coil-1-n-o-aux\"\u003e9A\u003c\/a\u003e, \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn1310nue-contactor-3p-13a-6kw-230v-coil-1-n-o-aux\"\u003e13A\u003c\/a\u003e, \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn1710nue-contactor-3p-17a-7-5kw-230v-coil-1-n-o-aux\"\u003e17A\u003c\/a\u003e and \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn2510nue-contactor-3p-25a-11kw-40a-heating-230v-coil-1-n-o-aux\"\u003e25A\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN HN1710NUE\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e17A AC3 \/ 7.5kW\u003c\/strong\u003e motor rating at 380-415V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30A AC1\u003c\/strong\u003e thermal rating for heaters and resistive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e230V AC coil\u003c\/strong\u003e, 50-60Hz, runs directly from UK mains control circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary\u003c\/strong\u003e: 1 N.O. built in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 million\u003c\/strong\u003e mechanical operations, 1 million electrical (EMAS data)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/EMAS-HN1710NUE-Datasheet.pdf\" title=\"EMAS HN1710NUE Datasheet Download\"\u003eEMAS HN1710NUE Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eTechnical Details\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17A (AC3), 30A (AC1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5kW at 380-415V, 4kW at 220-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220-230V AC 50-60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Frequency (On-Off\/Hour)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMech. 1800, Elec. 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1890V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MΩ (500V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 \/ +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTS EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHN Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the difference between AC1 and AC3 ratings?\u003c\/strong\u003e\u003cbr\u003eAC1 applies to resistive loads such as heating elements and gives the higher rating (30A). AC3 applies to inductive loads such as three-phase motors and is lower (17A \/ 7.5kW at 400V) because motor inrush current is harder on the contacts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill the 230V coil work on UK 240V mains?\u003c\/strong\u003e\u003cbr\u003eYes. UK mains is nominally 230V, often measured at around 240V, which is within the coil's normal operating tolerance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs there a version with the other auxiliary contact?\u003c\/strong\u003e\u003cbr\u003eYes. The \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn1701nue-contactor-3p-17a-7-5kw-230v-coil-1-n-c-aux\"\u003eHN1701NUE\u003c\/a\u003e is the 1 N.C. auxiliary version of this contactor. Use N.O. for a run or feedback signal and N.C. for interlocking or fault indication.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this replace my existing branded contactor?\u003c\/strong\u003e\u003cbr\u003eLikely yes. It is a common form-factor replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Check that the coil voltage, load rating and auxiliary contacts match before ordering.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be used outdoors or in a washdown area?\u003c\/strong\u003e\u003cbr\u003eNo. It is IP20 and must be mounted inside an enclosed control panel.\u003c\/p\u003e\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvens, kilns \u0026amp; heaters\u003c\/strong\u003e — switching heating elements up to 30A from a temperature controller relay or SSR output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor control panels\u003c\/strong\u003e — starters for pumps, fans, compressors and conveyors up to 7.5kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel refurbishment\u003c\/strong\u003e — drop-in replacement for ageing or discontinued branded contactors\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTroubleshooting \u0026amp; Guides\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/kiln-temperature-control\"\u003eKiln Temperature Control\u003c\/a\u003e — how contactors fit into a kiln control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/kiln-controller-upgrade-parts\"\u003eKiln Controller Upgrade Parts\u003c\/a\u003e — choosing the controller, SSR or contactor for an upgrade\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/faultfinding\"\u003eFaultfinding\u003c\/a\u003e — diagnosing a contactor that will not pull in or chatters\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/knowledge-base\"\u003eKnowledge Base\u003c\/a\u003e — all our technical guides in one place\u003c\/li\u003e\n\u003c\/ul\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the difference between AC1 and AC3 ratings?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"AC1 applies to resistive loads such as heating elements and gives the higher rating (30A). AC3 applies to inductive loads such as three-phase motors and is lower (17A \/ 7.5kW at 400V) because motor inrush current is harder on the contacts.\"}}, {\"@type\": \"Question\", \"name\": \"Will the 230V coil work on UK 240V mains?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. UK mains is nominally 230V, often measured at around 240V, which is within the coil's normal operating tolerance.\"}}, {\"@type\": \"Question\", \"name\": \"Is there a version with the other auxiliary contact?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The HN1701NUE is the 1 N.C. auxiliary version of this contactor. Use N.O. for a run or feedback signal and N.C. for interlocking or fault indication.\"}}, {\"@type\": \"Question\", \"name\": \"Can this replace my existing branded contactor?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Likely yes. It is a common form-factor replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Check that the coil voltage, load rating and auxiliary contacts match before ordering.\"}}, {\"@type\": \"Question\", \"name\": \"Can it be used outdoors or in a washdown area?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. It is IP20 and must be mounted inside an enclosed control panel.\"}}]}\u003c\/script\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57762740896117,"sku":"HN1710NUE","price":40.66,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/HN0910NUE_2.png?v=1662395774"},{"product_id":"emas-hn1701nue-contactor-3p-17a-7-5kw-230v-coil-1-n-c-aux","title":"EMAS HN1701NUE - Contactor 3P 17A 7.5KW \/ 30A Heating (230V AC Coil 1 N.C. Aux)","description":"\u003ch2\u003e\u003cstrong\u003e17A 3-Pole Contactor With 230V AC Coil And 1 N.C. Auxiliary\u003c\/strong\u003e\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003eEMAS HN1701NUE\u003c\/strong\u003e is a 3 pole HN series contactor with a 230V AC coil and one normally closed (N.C.) auxiliary contact, for DIN rail or panel mounting. It switches three-phase motors up to 7.5kW at 400V (17A AC3) and resistive heating loads up to 30A (AC1). The built-in N.C. auxiliary is ideal for interlocking or fault indication, opening as the contactor pulls in.\u003c\/p\u003e\u003cp\u003eA common replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Other HN sizes: \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn0910nue-contactor-9a-4kw-230v-coil-1-n-o-aux\"\u003e9A\u003c\/a\u003e, \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn1310nue-contactor-3p-13a-6kw-230v-coil-1-n-o-aux\"\u003e13A\u003c\/a\u003e, \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn1710nue-contactor-3p-17a-7-5kw-230v-coil-1-n-o-aux\"\u003e17A\u003c\/a\u003e and \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn2510nue-contactor-3p-25a-11kw-40a-heating-230v-coil-1-n-o-aux\"\u003e25A\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMPN HN1701NUE\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e17A AC3 \/ 7.5kW\u003c\/strong\u003e motor rating at 380-415V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e30A AC1\u003c\/strong\u003e thermal rating for heaters and resistive loads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e230V AC coil\u003c\/strong\u003e, 50-60Hz, runs directly from UK mains control circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary\u003c\/strong\u003e: 1 N.C. built in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10 million\u003c\/strong\u003e mechanical operations, 1 million electrical (EMAS data)\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/EMAS-HN1701NUE-Datasheet.pdf\" title=\"EMAS HN1701NUE Datasheet Download\"\u003eEMAS HN1701NUE Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ch3\u003eTechnical Details\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCurrent (Ie)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17A (AC3), 30A (AC1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMotor Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7.5kW at 380-415V, 4kW at 220-240V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePoles\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCoil Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e220-230V AC 50-60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMechanical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10,000,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrical Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000,000 operations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Frequency (On-Off\/Hour)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMech. 1800, Elec. 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e690V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDielectric Strength\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1890V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 MΩ (500V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-15 \/ +80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2,5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,8 Nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShort Circuit Breaking Capacity (Ics)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTS EN 60947-4-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHN Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the difference between AC1 and AC3 ratings?\u003c\/strong\u003e\u003cbr\u003eAC1 applies to resistive loads such as heating elements and gives the higher rating (30A). AC3 applies to inductive loads such as three-phase motors and is lower (17A \/ 7.5kW at 400V) because motor inrush current is harder on the contacts.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWill the 230V coil work on UK 240V mains?\u003c\/strong\u003e\u003cbr\u003eYes. UK mains is nominally 230V, often measured at around 240V, which is within the coil's normal operating tolerance.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs there a version with the other auxiliary contact?\u003c\/strong\u003e\u003cbr\u003eYes. The \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn1710nue-contactor-3p-17a-7-5kw-230v-coil-1-n-o-aux\"\u003eHN1710NUE\u003c\/a\u003e is the 1 N.O. auxiliary version of this contactor. Use N.O. for a run or feedback signal and N.C. for interlocking or fault indication.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this replace my existing branded contactor?\u003c\/strong\u003e\u003cbr\u003eLikely yes. It is a common form-factor replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Check that the coil voltage, load rating and auxiliary contacts match before ordering.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan it be used outdoors or in a washdown area?\u003c\/strong\u003e\u003cbr\u003eNo. It is IP20 and must be mounted inside an enclosed control panel.\u003c\/p\u003e\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOvens, kilns \u0026amp; heaters\u003c\/strong\u003e — switching heating elements up to 30A from a temperature controller relay or SSR output\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotor control panels\u003c\/strong\u003e — starters for pumps, fans, compressors and conveyors up to 7.5kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel refurbishment\u003c\/strong\u003e — drop-in replacement for ageing or discontinued branded contactors\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTroubleshooting \u0026amp; Guides\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/kiln-temperature-control\"\u003eKiln Temperature Control\u003c\/a\u003e — how contactors fit into a kiln control circuit\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/kiln-controller-upgrade-parts\"\u003eKiln Controller Upgrade Parts\u003c\/a\u003e — choosing the controller, SSR or contactor for an upgrade\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/faultfinding\"\u003eFaultfinding\u003c\/a\u003e — diagnosing a contactor that will not pull in or chatters\u003c\/li\u003e\n\u003cli\u003e\n\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/knowledge-base\"\u003eKnowledge Base\u003c\/a\u003e — all our technical guides in one place\u003c\/li\u003e\n\u003c\/ul\u003e\u003cscript type=\"application\/ld+json\"\u003e{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"What is the difference between AC1 and AC3 ratings?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"AC1 applies to resistive loads such as heating elements and gives the higher rating (30A). AC3 applies to inductive loads such as three-phase motors and is lower (17A \/ 7.5kW at 400V) because motor inrush current is harder on the contacts.\"}}, {\"@type\": \"Question\", \"name\": \"Will the 230V coil work on UK 240V mains?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. UK mains is nominally 230V, often measured at around 240V, which is within the coil's normal operating tolerance.\"}}, {\"@type\": \"Question\", \"name\": \"Is there a version with the other auxiliary contact?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. The HN1710NUE is the 1 N.O. auxiliary version of this contactor. Use N.O. for a run or feedback signal and N.C. for interlocking or fault indication.\"}}, {\"@type\": \"Question\", \"name\": \"Can this replace my existing branded contactor?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Likely yes. It is a common form-factor replacement for Crompton, Schneider, Telemecanique, ABB and similar contactors. Check that the coil voltage, load rating and auxiliary contacts match before ordering.\"}}, {\"@type\": \"Question\", \"name\": \"Can it be used outdoors or in a washdown area?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. It is IP20 and must be mounted inside an enclosed control panel.\"}}]}\u003c\/script\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57762741191029,"sku":"HN1701NUE","price":40.66,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/HN0910NUE_2.png?v=1662395774"}],"url":"https:\/\/www.production-automation.co.uk\/fr\/collections\/contactors.oembed","provider":"Production Automation","version":"1.0","type":"link"}