{"title":"Motor Protection Switches","description":"\u003cp\u003eEMAS MKS series manual motor protection switches (MPCBs) for 35mm DIN rail, covering motor currents from 0.25A to 25A. Each combines adjustable thermal overload, magnetic short-circuit and phase-loss protection with local isolation. Choose the range that brackets your motor's nameplate current. See also \u003ca href=\"\/de\/collections\/motor-control\"\u003eMotor Control\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"emas-mks1tm-1-mks-series-0-63-1-00a-motor-protection-switch","title":"EMAS MKS1TM-1 - MKS Series 0.63-1.00A Motor Protection Switch","description":"\u003ch2\u003eEMAS MKS1TM-1 - MKS Series 0.63-1.00A Motor Protection Switch\u003c\/h2\u003e\n\u003cp\u003eA DIN rail mounted manual motor protection switch (motor circuit breaker) from EMAS's MKS series, thermally calibrated over a 0.63-1.00A range to match the full load current of small single-phase or three-phase motors.\u003c\/p\u003e\n\u003cp\u003eUnlike a standard MCB, which just protects the wiring against overload and short circuit, a motor protection switch is designed specifically to protect the motor itself. It combines two separate protection mechanisms in one DIN rail device:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal overload protection\u003c\/strong\u003e - an adjustable dial lets you set the trip current to match the motor's actual full load amps (FLA), so the switch trips on a sustained overload but rides through the normal high inrush current of motor starting without nuisance tripping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed magnetic short-circuit protection\u003c\/strong\u003e - trips instantly at 12x the dial setting to clear a genuine short circuit or locked-rotor fault, rated to at least 6kA\/400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase deficiency protection\u003c\/strong\u003e - detects loss of one phase on a 3-phase motor and trips before the motor can be damaged running single-phased\u003c\/li\u003e\n\u003cli\u003eAmbient temperature compensated, so the trip point doesn't drift with panel temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSuitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e35mm DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eDirect-on-line (DOL) starting of small motors within this current range\u003c\/li\u003e\n\u003cli\u003eRetrofit motor protection upgrades where a simple MCB or fuse currently offers no overload\/single-phasing protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eThermic Current Calibration\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e0.63-1.00A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e25A (switch rating)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eTS EN 60947-4-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e690V AC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eShort Circuit Rating\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e6kA \/ 400V (fixed at 12x Ie)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eUsage Category\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eAC-3 (motor loads)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eIP40\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e-5°C to +40°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e0.75-4mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.8Nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMechanical\/Electrical Life\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e100,000 operations\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e35mm DIN Rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from a normal MCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects the cable, not the motor - it has one fixed trip curve and no allowance for motor starting current. This motor protection switch has an adjustable thermal dial matched to your motor's actual running current, plus separate fixed short-circuit and single-phasing protection - all in one device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set it up?\u003c\/strong\u003e\u003cbr\u003eSet the dial to your motor's full load current (FLA), found on the motor's nameplate. The thermal element then protects against sustained overload while tolerating normal starting inrush.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it protect against a motor losing a phase?\u003c\/strong\u003e\u003cbr\u003eYes - phase deficiency (single-phasing) protection is built in, which a standard MCB does not provide.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you stock other current ranges?\u003c\/strong\u003e\u003cbr\u003eYes - see our \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-4-mks-series-2-50-4-00a-motor-protection-switch\" title=\"EMAS MKS1TM-4\" style=\"color:blue;font-weight:bold;\"\u003eMKS1TM-4 (2.50-4.00A)\u003c\/a\u003e for the next size up.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine building \u0026amp; OEM panels\u003c\/strong\u003e - compact combined motor protection in place of separate MCB + overload relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofit upgrades\u003c\/strong\u003e - adding proper motor protection to older panels that only have basic fusing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump, fan and conveyor drives\u003c\/strong\u003e - direct-on-line motor circuits needing overload and single-phasing protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57611619271029,"sku":"MKS1TM-1","price":61.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/MKS1TM-1_20_1.jpg?v=1790476162"},{"product_id":"emas-mks1tm-4-mks-series-2-50-4-00a-motor-protection-switch","title":"EMAS MKS1TM-4 - MKS Series 2.50-4.00A Motor Protection Switch","description":"\u003ch2\u003eEMAS MKS1TM-4 - MKS Series 2.50-4.00A Motor Protection Switch\u003c\/h2\u003e\n\u003cp\u003eA DIN rail mounted manual motor protection switch (motor circuit breaker) from EMAS's MKS series, thermally calibrated over a 2.50-4.00A range to match the full load current of small single-phase or three-phase motors.\u003c\/p\u003e\n\u003cp\u003eUnlike a standard MCB, which just protects the wiring against overload and short circuit, a motor protection switch is designed specifically to protect the motor itself. It combines two separate protection mechanisms in one DIN rail device:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal overload protection\u003c\/strong\u003e - an adjustable dial lets you set the trip current to match the motor's actual full load amps (FLA), so the switch trips on a sustained overload but rides through the normal high inrush current of motor starting without nuisance tripping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed magnetic short-circuit protection\u003c\/strong\u003e - trips instantly at 12x the dial setting to clear a genuine short circuit or locked-rotor fault, rated to at least 6kA\/400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase deficiency protection\u003c\/strong\u003e - detects loss of one phase on a 3-phase motor and trips before the motor can be damaged running single-phased\u003c\/li\u003e\n\u003cli\u003eAmbient temperature compensated, so the trip point doesn't drift with panel temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSuitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e35mm DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eDirect-on-line (DOL) starting of small motors within this current range\u003c\/li\u003e\n\u003cli\u003eRetrofit motor protection upgrades where a simple MCB or fuse currently offers no overload\/single-phasing protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eThermic Current Calibration\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e2.50-4.00A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e25A (switch rating)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eTS EN 60947-4-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e690V AC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eShort Circuit Rating\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e6kA \/ 400V (fixed at 12x Ie)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eUsage Category\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eAC-3 (motor loads)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eIP40\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e-5°C to +40°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e0.75-4mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.8Nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMechanical\/Electrical Life\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e100,000 operations\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e35mm DIN Rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from a normal MCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects the cable, not the motor - it has one fixed trip curve and no allowance for motor starting current. This motor protection switch has an adjustable thermal dial matched to your motor's actual running current, plus separate fixed short-circuit and single-phasing protection - all in one device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set it up?\u003c\/strong\u003e\u003cbr\u003eSet the dial to your motor's full load current (FLA), found on the motor's nameplate. The thermal element then protects against sustained overload while tolerating normal starting inrush.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it protect against a motor losing a phase?\u003c\/strong\u003e\u003cbr\u003eYes - phase deficiency (single-phasing) protection is built in, which a standard MCB does not provide.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you stock other current ranges?\u003c\/strong\u003e\u003cbr\u003eYes - see our \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-1-mks-series-0-63-1-00a-motor-protection-switch\" title=\"EMAS MKS1TM-1\" style=\"color:blue;font-weight:bold;\"\u003eMKS1TM-1 (0.63-1.00A)\u003c\/a\u003e for smaller motors, or our \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-10-mks-series-6-30-10-0a-motor-protection-switch\" title=\"EMAS MKS1TM-10\" style=\"color:blue;font-weight:bold;\"\u003eMKS1TM-10 (6.30-10.0A)\u003c\/a\u003e for larger ones.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine building \u0026amp; OEM panels\u003c\/strong\u003e - compact combined motor protection in place of separate MCB + overload relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofit upgrades\u003c\/strong\u003e - adding proper motor protection to older panels that only have basic fusing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump, fan and conveyor drives\u003c\/strong\u003e - direct-on-line motor circuits needing overload and single-phasing protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57611619303797,"sku":"MKS1TM-4","price":61.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/MKS1TM-4_20_1.jpg?v=1790476162"},{"product_id":"emas-mks1tm-10-mks-series-6-30-10-0a-motor-protection-switch","title":"EMAS MKS1TM-10 - MKS Series 6.30-10.0A Motor Protection Switch","description":"\u003ch2\u003eEMAS MKS1TM-10 - MKS Series 6.30-10.0A Motor Protection Switch\u003c\/h2\u003e\n\u003cp\u003eA DIN rail mounted manual motor protection switch (motor circuit breaker) from EMAS's MKS series, thermally calibrated over a 6.30-10.0A range to match the full load current of small single-phase or three-phase motors.\u003c\/p\u003e\n\u003cp\u003eUnlike a standard MCB, which just protects the wiring against overload and short circuit, a motor protection switch is designed specifically to protect the motor itself. It combines two separate protection mechanisms in one DIN rail device:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal overload protection\u003c\/strong\u003e - an adjustable dial lets you set the trip current to match the motor's actual full load amps (FLA), so the switch trips on a sustained overload but rides through the normal high inrush current of motor starting without nuisance tripping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed magnetic short-circuit protection\u003c\/strong\u003e - trips instantly at 12x the dial setting to clear a genuine short circuit or locked-rotor fault, rated to at least 6kA\/400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase deficiency protection\u003c\/strong\u003e - detects loss of one phase on a 3-phase motor and trips before the motor can be damaged running single-phased\u003c\/li\u003e\n\u003cli\u003eAmbient temperature compensated, so the trip point doesn't drift with panel temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSuitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e35mm DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eDirect-on-line (DOL) starting of small motors within this current range\u003c\/li\u003e\n\u003cli\u003eRetrofit motor protection upgrades where a simple MCB or fuse currently offers no overload\/single-phasing protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eThermic Current Calibration\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e6.30-10.0A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e25A (switch rating)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eTS EN 60947-4-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e690V AC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eShort Circuit Rating\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e6kA \/ 400V (fixed at 12x Ie)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eUsage Category\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eAC-3 (motor loads)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eIP40\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e-5°C to +40°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e0.75-4mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.8Nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMechanical\/Electrical Life\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e100,000 operations\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e35mm DIN Rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from a normal MCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects the cable, not the motor - it has one fixed trip curve and no allowance for motor starting current. This motor protection switch has an adjustable thermal dial matched to your motor's actual running current, plus separate fixed short-circuit and single-phasing protection - all in one device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set it up?\u003c\/strong\u003e\u003cbr\u003eSet the dial to your motor's full load current (FLA), found on the motor's nameplate. The thermal element then protects against sustained overload while tolerating normal starting inrush.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it protect against a motor losing a phase?\u003c\/strong\u003e\u003cbr\u003eYes - phase deficiency (single-phasing) protection is built in, which a standard MCB does not provide.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you stock other current ranges?\u003c\/strong\u003e\u003cbr\u003eYes - see our \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-4-mks-series-2-50-4-00a-motor-protection-switch\" title=\"EMAS MKS1TM-4\" style=\"color:blue;font-weight:bold;\"\u003eMKS1TM-4 (2.50-4.00A)\u003c\/a\u003e for smaller motors, or our \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-16-mks-series-10-0-16-0a-motor-protection-switch\" title=\"EMAS MKS1TM-16\" style=\"color:blue;font-weight:bold;\"\u003eMKS1TM-16 (10.0-16.0A)\u003c\/a\u003e for larger ones.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine building \u0026amp; OEM panels\u003c\/strong\u003e - compact combined motor protection in place of separate MCB + overload relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofit upgrades\u003c\/strong\u003e - adding proper motor protection to older panels that only have basic fusing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump, fan and conveyor drives\u003c\/strong\u003e - direct-on-line motor circuits needing overload and single-phasing protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57611619336565,"sku":"MKS1TM-10","price":61.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/MKS1TM-10_20_1.jpg?v=1790476162"},{"product_id":"emas-mks1tm-16-mks-series-10-0-16-0a-motor-protection-switch","title":"EMAS MKS1TM-16 - MKS Series 10.0-16.0A Motor Protection Switch","description":"\u003ch2\u003eEMAS MKS1TM-16 - MKS Series 10.0-16.0A Motor Protection Switch\u003c\/h2\u003e\n\u003cp\u003eA DIN rail mounted manual motor protection switch (motor circuit breaker) from EMAS's MKS series, thermally calibrated over a 10.0-16.0A range to match the full load current of small single-phase or three-phase motors.\u003c\/p\u003e\n\u003cp\u003eUnlike a standard MCB, which just protects the wiring against overload and short circuit, a motor protection switch is designed specifically to protect the motor itself. It combines two separate protection mechanisms in one DIN rail device:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal overload protection\u003c\/strong\u003e - an adjustable dial lets you set the trip current to match the motor's actual full load amps (FLA), so the switch trips on a sustained overload but rides through the normal high inrush current of motor starting without nuisance tripping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed magnetic short-circuit protection\u003c\/strong\u003e - trips instantly at 12x the dial setting to clear a genuine short circuit or locked-rotor fault, rated to at least 6kA\/400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase deficiency protection\u003c\/strong\u003e - detects loss of one phase on a 3-phase motor and trips before the motor can be damaged running single-phased\u003c\/li\u003e\n\u003cli\u003eAmbient temperature compensated, so the trip point doesn't drift with panel temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSuitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e35mm DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eDirect-on-line (DOL) starting of small motors within this current range\u003c\/li\u003e\n\u003cli\u003eRetrofit motor protection upgrades where a simple MCB or fuse currently offers no overload\/single-phasing protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eThermic Current Calibration\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e10.0-16.0A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e25A (switch rating)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eTS EN 60947-4-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e690V AC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eShort Circuit Rating\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e6kA \/ 400V (fixed at 12x Ie)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eUsage Category\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eAC-3 (motor loads)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eIP40\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e-5°C to +40°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e0.75-4mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.8Nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMechanical\/Electrical Life\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e100,000 operations\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e35mm DIN Rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from a normal MCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects the cable, not the motor - it has one fixed trip curve and no allowance for motor starting current. This motor protection switch has an adjustable thermal dial matched to your motor's actual running current, plus separate fixed short-circuit and single-phasing protection - all in one device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set it up?\u003c\/strong\u003e\u003cbr\u003eSet the dial to your motor's full load current (FLA), found on the motor's nameplate. The thermal element then protects against sustained overload while tolerating normal starting inrush.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it protect against a motor losing a phase?\u003c\/strong\u003e\u003cbr\u003eYes - phase deficiency (single-phasing) protection is built in, which a standard MCB does not provide.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you stock other current ranges?\u003c\/strong\u003e\u003cbr\u003eYes - see our \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-10-mks-series-6-30-10-0a-motor-protection-switch\" title=\"EMAS MKS1TM-10\" style=\"color:blue;font-weight:bold;\"\u003eMKS1TM-10 (6.30-10.0A)\u003c\/a\u003e for smaller motors, or our \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-20-mks-series-16-0-20-0a-motor-protection-switch\" title=\"EMAS MKS1TM-20\" style=\"color:blue;font-weight:bold;\"\u003eMKS1TM-20 (16.0-20.0A)\u003c\/a\u003e for larger ones.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine building \u0026amp; OEM panels\u003c\/strong\u003e - compact combined motor protection in place of separate MCB + overload relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofit upgrades\u003c\/strong\u003e - adding proper motor protection to older panels that only have basic fusing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump, fan and conveyor drives\u003c\/strong\u003e - direct-on-line motor circuits needing overload and single-phasing protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57611619402101,"sku":"MKS1TM-16","price":61.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/MKS1TM-16_20_1.jpg?v=1790476163"},{"product_id":"emas-mks1tm-20-mks-series-16-0-20-0a-motor-protection-switch","title":"EMAS MKS1TM-20 - MKS Series 16.0-20.0A Motor Protection Switch","description":"\u003ch2\u003eEMAS MKS1TM-20 - MKS Series 16.0-20.0A Motor Protection Switch\u003c\/h2\u003e\n\u003cp\u003eA DIN rail mounted manual motor protection switch (motor circuit breaker) from EMAS's MKS series, thermally calibrated over a 16.0-20.0A range to match the full load current of small single-phase or three-phase motors.\u003c\/p\u003e\n\u003cp\u003eUnlike a standard MCB, which just protects the wiring against overload and short circuit, a motor protection switch is designed specifically to protect the motor itself. It combines two separate protection mechanisms in one DIN rail device:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal overload protection\u003c\/strong\u003e - an adjustable dial lets you set the trip current to match the motor's actual full load amps (FLA), so the switch trips on a sustained overload but rides through the normal high inrush current of motor starting without nuisance tripping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed magnetic short-circuit protection\u003c\/strong\u003e - trips instantly at 12x the dial setting to clear a genuine short circuit or locked-rotor fault, rated to at least 6kA\/400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase deficiency protection\u003c\/strong\u003e - detects loss of one phase on a 3-phase motor and trips before the motor can be damaged running single-phased\u003c\/li\u003e\n\u003cli\u003eAmbient temperature compensated, so the trip point doesn't drift with panel temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSuitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e35mm DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eDirect-on-line (DOL) starting of small motors within this current range\u003c\/li\u003e\n\u003cli\u003eRetrofit motor protection upgrades where a simple MCB or fuse currently offers no overload\/single-phasing protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eThermic Current Calibration\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e16.0-20.0A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e25A (switch rating)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eTS EN 60947-4-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e690V AC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eShort Circuit Rating\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e6kA \/ 400V (fixed at 12x Ie)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eUsage Category\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eAC-3 (motor loads)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eIP40\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e-5°C to +40°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e0.75-4mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.8Nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMechanical\/Electrical Life\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e100,000 operations\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e35mm DIN Rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from a normal MCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects the cable, not the motor - it has one fixed trip curve and no allowance for motor starting current. This motor protection switch has an adjustable thermal dial matched to your motor's actual running current, plus separate fixed short-circuit and single-phasing protection - all in one device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set it up?\u003c\/strong\u003e\u003cbr\u003eSet the dial to your motor's full load current (FLA), found on the motor's nameplate. The thermal element then protects against sustained overload while tolerating normal starting inrush.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it protect against a motor losing a phase?\u003c\/strong\u003e\u003cbr\u003eYes - phase deficiency (single-phasing) protection is built in, which a standard MCB does not provide.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you stock other current ranges?\u003c\/strong\u003e\u003cbr\u003eYes - see our \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-16-mks-series-10-0-16-0a-motor-protection-switch\" title=\"EMAS MKS1TM-16\" style=\"color:blue;font-weight:bold;\"\u003eMKS1TM-16 (10.0-16.0A)\u003c\/a\u003e for smaller motors, or our \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-25-mks-series-20-0-25-0a-motor-protection-switch\" title=\"EMAS MKS1TM-25\" style=\"color:blue;font-weight:bold;\"\u003eMKS1TM-25 (20.0-25.0A)\u003c\/a\u003e for larger ones.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine building \u0026amp; OEM panels\u003c\/strong\u003e - compact combined motor protection in place of separate MCB + overload relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofit upgrades\u003c\/strong\u003e - adding proper motor protection to older panels that only have basic fusing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump, fan and conveyor drives\u003c\/strong\u003e - direct-on-line motor circuits needing overload and single-phasing protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57611619434869,"sku":"MKS1TM-20","price":61.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/MKS1TM-20_20_1.jpg?v=1790476163"},{"product_id":"emas-mks1tm-25-mks-series-20-0-25-0a-motor-protection-switch","title":"EMAS MKS1TM-25 - MKS Series 20.0-25.0A Motor Protection Switch","description":"\u003ch2\u003eEMAS MKS1TM-25 - MKS Series 20.0-25.0A Motor Protection Switch\u003c\/h2\u003e\n\u003cp\u003eA DIN rail mounted manual motor protection switch (motor circuit breaker) from EMAS's MKS series, thermally calibrated over a 20.0-25.0A range to match the full load current of small single-phase or three-phase motors. This is the largest current rating in the MKS series.\u003c\/p\u003e\n\u003cp\u003eUnlike a standard MCB, which just protects the wiring against overload and short circuit, a motor protection switch is designed specifically to protect the motor itself. It combines two separate protection mechanisms in one DIN rail device:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal overload protection\u003c\/strong\u003e - an adjustable dial lets you set the trip current to match the motor's actual full load amps (FLA), so the switch trips on a sustained overload but rides through the normal high inrush current of motor starting without nuisance tripping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed magnetic short-circuit protection\u003c\/strong\u003e - trips instantly at 12x the dial setting to clear a genuine short circuit or locked-rotor fault, rated to at least 6kA\/400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase deficiency protection\u003c\/strong\u003e - detects loss of one phase on a 3-phase motor and trips before the motor can be damaged running single-phased\u003c\/li\u003e\n\u003cli\u003eAmbient temperature compensated, so the trip point doesn't drift with panel temperature\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSuitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e35mm DIN rail mounting\u003c\/li\u003e\n\u003cli\u003eDirect-on-line (DOL) starting of small motors within this current range\u003c\/li\u003e\n\u003cli\u003eRetrofit motor protection upgrades where a simple MCB or fuse currently offers no overload\/single-phasing protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Data\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eThermic Current Calibration\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e20.0-25.0A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e25A (switch rating)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eTS EN 60947-4-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e690V AC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eShort Circuit Rating\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e6kA \/ 400V (fixed at 12x Ie)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eUsage Category\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eAC-3 (motor loads)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eIP40\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e-5°C to +40°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e0.75-4mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.8Nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMechanical\/Electrical Life\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e100,000 operations\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e35mm DIN Rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from a normal MCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects the cable, not the motor - it has one fixed trip curve and no allowance for motor starting current. This motor protection switch has an adjustable thermal dial matched to your motor's actual running current, plus separate fixed short-circuit and single-phasing protection - all in one device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I set it up?\u003c\/strong\u003e\u003cbr\u003eSet the dial to your motor's full load current (FLA), found on the motor's nameplate. The thermal element then protects against sustained overload while tolerating normal starting inrush.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it protect against a motor losing a phase?\u003c\/strong\u003e\u003cbr\u003eYes - phase deficiency (single-phasing) protection is built in, which a standard MCB does not provide.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo you stock other current ranges?\u003c\/strong\u003e\u003cbr\u003eYes - see our \u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-20-mks-series-16-0-20-0a-motor-protection-switch\" title=\"EMAS MKS1TM-20\" style=\"color:blue;font-weight:bold;\"\u003eMKS1TM-20 (16.0-20.0A)\u003c\/a\u003e for the next size down.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine building \u0026amp; OEM panels\u003c\/strong\u003e - compact combined motor protection in place of separate MCB + overload relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofit upgrades\u003c\/strong\u003e - adding proper motor protection to older panels that only have basic fusing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump, fan and conveyor drives\u003c\/strong\u003e - direct-on-line motor circuits needing overload and single-phasing protection\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57611619467637,"sku":"MKS1TM-25","price":61.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/MKS1TM-25_20_1.jpg?v=1790476163"},{"product_id":"emas-mks1tm-0-63-mks-series-0-40-0-63a-motor-protection-switch","title":"EMAS MKS1TM-0.63 - MKS Series 0.40-0.63A Motor Protection Switch","description":"\u003ch2\u003e\u003cstrong\u003eProper Motor Protection For Very Small Motors, 0.40-0.63A\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEMAS MKS1TM-0.63\u003c\/strong\u003e is a DIN rail manual motor protection switch (MPCB) for motors drawing between 0.40A and 0.63A at full load, such as small fans, dosing pumps and light conveyor drives. It combines adjustable thermal overload, fixed magnetic short-circuit and phase-loss protection in one compact device, and doubles as the motor's local isolator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMPN MKS1TM-0.63\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable thermal overload\u003c\/strong\u003e - set the dial to the motor's nameplate current anywhere from 0.40A to 0.63A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed magnetic trip at 12 x Ie\u003c\/strong\u003e - clears short circuits instantly, with a breaking capacity of at least 6kA at 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase deficiency protection\u003c\/strong\u003e - trips if a 3-phase motor loses a phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature compensated\u003c\/strong\u003e - the trip point stays consistent as panel temperature changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eThermic Current Calibration\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e0.40-0.63A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e25A (switch rating)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eTS EN 60947-4-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperational Frequency\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e50-60Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eUsage Category\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eAC-3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eFixed at 12 x Ie, min. 6kA \/ 400V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e690V AC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e6kV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMechanical \/ Electrical Life\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e100,000 \/ 100,000 operations (min.)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e360 operations\/hour\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eIP40\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e-5°C to +40°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e0.75-4mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.8Nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e35mm DIN rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from a normal MCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects the cable with a fixed trip curve. The MKS1TM-0.63 protects the motor itself: its thermal trip is set to the motor's running current, it rides through starting inrush, and it adds phase-loss protection that an MCB does not have.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose and set the right range?\u003c\/strong\u003e\u003cbr\u003eRead the full load current from the motor nameplate. If it falls between 0.40A and 0.63A, this is the right switch; set the dial to that value. Slightly larger motors need the MKS1TM-1 (0.63-1.00A).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be mounted outside a panel?\u003c\/strong\u003e\u003cbr\u003eNo. The switch is rated IP40, so it should be fitted on 35mm DIN rail inside an enclosure. EMAS also make an enclosed MKS1TMK version for surface mounting; ask us if you need one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable sizes does it accept?\u003c\/strong\u003e\u003cbr\u003eThe terminals take 0.75mm² to 4mm² conductors, tightened to 1.8Nm. Auxiliary contacts and other MKS accessories are sold separately.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall fans and blowers\u003c\/strong\u003e - overload and phase-loss protection for low-current extraction and cooling motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDosing and circulation pumps\u003c\/strong\u003e - a combined isolator and motor protector in a single DIN rail module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLight conveyors and OEM machines\u003c\/strong\u003e - compact protection for fractional-horsepower drives in machine panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed a different range? See the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-1-mks-series-0-63-1-00a-motor-protection-switch\" style=\"color: rgb(43, 0, 255);\"\u003eEMAS MKS1TM-1 (0.63-1.00A)\u003c\/a\u003e\u003c\/strong\u003e or the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-4-mks-series-2-50-4-00a-motor-protection-switch\" style=\"color: rgb(43, 0, 255);\"\u003eEMAS MKS1TM-4 (2.50-4.00A)\u003c\/a\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How is this different from a normal MCB?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"An MCB protects the cable with a fixed trip curve. The MKS1TM-0.63 protects the motor itself: its thermal trip is set to the motor's running current, it rides through starting inrush, and it adds phase-loss protection that an MCB does not have.\"}},{\"@type\":\"Question\",\"name\":\"How do I choose and set the right range?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Read the full load current from the motor nameplate. If it falls between 0.40A and 0.63A, this is the right switch; set the dial to that value. Slightly larger motors need the MKS1TM-1 (0.63-1.00A).\"}},{\"@type\":\"Question\",\"name\":\"Can it be mounted outside a panel?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The switch is rated IP40, so it should be fitted on 35mm DIN rail inside an enclosure. EMAS also make an enclosed MKS1TMK version for surface mounting; ask us if you need one.\"}},{\"@type\":\"Question\",\"name\":\"What cable sizes does it accept?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The terminals take 0.75mm² to 4mm² conductors, tightened to 1.8Nm. Auxiliary contacts and other MKS accessories are sold separately.\"}}]}\n\u003c\/script\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57710365671797,"sku":"MKS1TM-0.63","price":61.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/MKS1TM-0_63_20_281_29.jpg?v=1793596922"},{"product_id":"emas-mks1tm-1-6-mks-series-1-00-1-60a-motor-protection-switch","title":"EMAS MKS1TM-1.6 - MKS Series 1.00-1.60A Motor Protection Switch","description":"\u003ch2\u003e\u003cstrong\u003eOverload, Short-Circuit And Phase-Loss Protection For 1.00-1.60A Motors\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEMAS MKS1TM-1.6\u003c\/strong\u003e is a DIN rail manual motor protection switch (MPCB) for motors with a full load current between 1.00A and 1.60A, a range that covers many small three-phase pumps, fans and gear motors. One compact device gives you adjustable thermal overload, fixed magnetic short-circuit and phase-loss protection, plus a local means of isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMPN MKS1TM-1.6\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable thermal overload\u003c\/strong\u003e - set the dial to the motor's nameplate current anywhere from 1.00A to 1.60A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed magnetic trip at 12 x Ie\u003c\/strong\u003e - clears short circuits instantly, with a breaking capacity of at least 6kA at 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase deficiency protection\u003c\/strong\u003e - trips if a 3-phase motor loses a phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature compensated\u003c\/strong\u003e - the trip point stays consistent as panel temperature changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eThermic Current Calibration\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.00-1.60A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e25A (switch rating)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eTS EN 60947-4-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperational Frequency\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e50-60Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eUsage Category\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eAC-3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eFixed at 12 x Ie, min. 6kA \/ 400V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e690V AC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e6kV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMechanical \/ Electrical Life\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e100,000 \/ 100,000 operations (min.)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e360 operations\/hour\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eIP40\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e-5°C to +40°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e0.75-4mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.8Nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e35mm DIN rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from a normal MCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects the cable with a fixed trip curve. The MKS1TM-1.6 protects the motor itself: its thermal trip is set to the motor's running current, it rides through starting inrush, and it adds phase-loss protection that an MCB does not have.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose and set the right range?\u003c\/strong\u003e\u003cbr\u003eRead the full load current from the motor nameplate. If it falls between 1.00A and 1.60A, this is the right switch; set the dial to that value. Below 1.00A use the MKS1TM-1; from 1.60A to 2.50A use the MKS1TM-2.5.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be mounted outside a panel?\u003c\/strong\u003e\u003cbr\u003eNo. The switch is rated IP40, so it should be fitted on 35mm DIN rail inside an enclosure. EMAS also make an enclosed MKS1TMK version for surface mounting; ask us if you need one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable sizes does it accept?\u003c\/strong\u003e\u003cbr\u003eThe terminals take 0.75mm² to 4mm² conductors, tightened to 1.8Nm. Auxiliary contacts and other MKS accessories are sold separately.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePumps and circulators\u003c\/strong\u003e - overload and single-phasing protection for small direct-on-line pump motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVentilation fans\u003c\/strong\u003e - a combined isolator and motor protector for extract and supply fan motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGear motors and conveyors\u003c\/strong\u003e - compact protection for small drives in machine-builder and OEM panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed a different range? See the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-1-mks-series-0-63-1-00a-motor-protection-switch\" style=\"color: rgb(43, 0, 255);\"\u003eEMAS MKS1TM-1 (0.63-1.00A)\u003c\/a\u003e\u003c\/strong\u003e or the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-4-mks-series-2-50-4-00a-motor-protection-switch\" style=\"color: rgb(43, 0, 255);\"\u003eEMAS MKS1TM-4 (2.50-4.00A)\u003c\/a\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How is this different from a normal MCB?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"An MCB protects the cable with a fixed trip curve. The MKS1TM-1.6 protects the motor itself: its thermal trip is set to the motor's running current, it rides through starting inrush, and it adds phase-loss protection that an MCB does not have.\"}},{\"@type\":\"Question\",\"name\":\"How do I choose and set the right range?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Read the full load current from the motor nameplate. If it falls between 1.00A and 1.60A, this is the right switch; set the dial to that value. Below 1.00A use the MKS1TM-1; from 1.60A to 2.50A use the MKS1TM-2.5.\"}},{\"@type\":\"Question\",\"name\":\"Can it be mounted outside a panel?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The switch is rated IP40, so it should be fitted on 35mm DIN rail inside an enclosure. EMAS also make an enclosed MKS1TMK version for surface mounting; ask us if you need one.\"}},{\"@type\":\"Question\",\"name\":\"What cable sizes does it accept?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The terminals take 0.75mm² to 4mm² conductors, tightened to 1.8Nm. Auxiliary contacts and other MKS accessories are sold separately.\"}}]}\n\u003c\/script\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57710365704565,"sku":"MKS1TM-1.6","price":61.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/MKS1TM-1_6_20_281_29.jpg?v=1793596959"},{"product_id":"emas-mks1tm-2-5-mks-series-1-60-2-50a-motor-protection-switch","title":"EMAS MKS1TM-2.5 - MKS Series 1.60-2.50A Motor Protection Switch","description":"\u003ch2\u003e\u003cstrong\u003eSet-And-Forget Motor Protection For 1.60-2.50A Motors\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEMAS MKS1TM-2.5\u003c\/strong\u003e is a DIN rail manual motor protection switch (MPCB) for motors with a full load current between 1.60A and 2.50A, typical of small three-phase pumps, compressors, mixers and conveyor drives. It brings adjustable thermal overload, fixed magnetic short-circuit and phase-loss protection together in one compact unit that also isolates the motor locally.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMPN MKS1TM-2.5\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable thermal overload\u003c\/strong\u003e - set the dial to the motor's nameplate current anywhere from 1.60A to 2.50A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed magnetic trip at 12 x Ie\u003c\/strong\u003e - clears short circuits instantly, with a breaking capacity of at least 6kA at 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase deficiency protection\u003c\/strong\u003e - trips if a 3-phase motor loses a phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature compensated\u003c\/strong\u003e - the trip point stays consistent as panel temperature changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eThermic Current Calibration\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.60-2.50A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e25A (switch rating)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eTS EN 60947-4-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperational Frequency\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e50-60Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eUsage Category\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eAC-3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eFixed at 12 x Ie, min. 6kA \/ 400V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e690V AC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e6kV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMechanical \/ Electrical Life\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e100,000 \/ 100,000 operations (min.)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e360 operations\/hour\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eIP40\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e-5°C to +40°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e0.75-4mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.8Nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e35mm DIN rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from a normal MCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects the cable with a fixed trip curve. The MKS1TM-2.5 protects the motor itself: its thermal trip is set to the motor's running current, it rides through starting inrush, and it adds phase-loss protection that an MCB does not have.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose and set the right range?\u003c\/strong\u003e\u003cbr\u003eRead the full load current from the motor nameplate. If it falls between 1.60A and 2.50A, this is the right switch; set the dial to that value. From 2.50A to 4.00A use the MKS1TM-4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be mounted outside a panel?\u003c\/strong\u003e\u003cbr\u003eNo. The switch is rated IP40, so it should be fitted on 35mm DIN rail inside an enclosure. EMAS also make an enclosed MKS1TMK version for surface mounting; ask us if you need one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable sizes does it accept?\u003c\/strong\u003e\u003cbr\u003eThe terminals take 0.75mm² to 4mm² conductors, tightened to 1.8Nm. Auxiliary contacts and other MKS accessories are sold separately.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall compressors and pumps\u003c\/strong\u003e - overload and single-phasing protection for direct-on-line motors in this current band\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMixers and agitators\u003c\/strong\u003e - trips on sustained overload if the load thickens or jams, protecting the motor windings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor and packaging drives\u003c\/strong\u003e - a compact combined isolator and motor protector for machine panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed a different range? See the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-4-mks-series-2-50-4-00a-motor-protection-switch\" style=\"color: rgb(43, 0, 255);\"\u003eEMAS MKS1TM-4 (2.50-4.00A)\u003c\/a\u003e\u003c\/strong\u003e or the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-1-mks-series-0-63-1-00a-motor-protection-switch\" style=\"color: rgb(43, 0, 255);\"\u003eEMAS MKS1TM-1 (0.63-1.00A)\u003c\/a\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How is this different from a normal MCB?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"An MCB protects the cable with a fixed trip curve. The MKS1TM-2.5 protects the motor itself: its thermal trip is set to the motor's running current, it rides through starting inrush, and it adds phase-loss protection that an MCB does not have.\"}},{\"@type\":\"Question\",\"name\":\"How do I choose and set the right range?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Read the full load current from the motor nameplate. If it falls between 1.60A and 2.50A, this is the right switch; set the dial to that value. From 2.50A to 4.00A use the MKS1TM-4.\"}},{\"@type\":\"Question\",\"name\":\"Can it be mounted outside a panel?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The switch is rated IP40, so it should be fitted on 35mm DIN rail inside an enclosure. EMAS also make an enclosed MKS1TMK version for surface mounting; ask us if you need one.\"}},{\"@type\":\"Question\",\"name\":\"What cable sizes does it accept?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The terminals take 0.75mm² to 4mm² conductors, tightened to 1.8Nm. Auxiliary contacts and other MKS accessories are sold separately.\"}}]}\n\u003c\/script\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57710365770101,"sku":"MKS1TM-2.5","price":61.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/MKS1TM-2_5_20_281_29.jpg?v=1793596991"},{"product_id":"emas-mks1tm-6-3-mks-series-4-00-6-30a-motor-protection-switch","title":"EMAS MKS1TM-6.3 - MKS Series 4.00-6.30A Motor Protection Switch","description":"\u003ch2\u003e\u003cstrong\u003eMotor Protection And Isolation For 4.00-6.30A Motors In One DIN Module\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEMAS MKS1TM-6.3\u003c\/strong\u003e is a DIN rail manual motor protection switch (MPCB) for motors with a full load current between 4.00A and 6.30A, a popular band for workshop machinery, larger pumps, fans and conveyor drives. It combines adjustable thermal overload, fixed magnetic short-circuit and phase-loss protection, and gives you a local on\/off isolator in the same compact unit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMPN MKS1TM-6.3\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable thermal overload\u003c\/strong\u003e - set the dial to the motor's nameplate current anywhere from 4.00A to 6.30A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed magnetic trip at 12 x Ie\u003c\/strong\u003e - clears short circuits instantly, with a breaking capacity of at least 6kA at 400V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase deficiency protection\u003c\/strong\u003e - trips if a 3-phase motor loses a phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature compensated\u003c\/strong\u003e - the trip point stays consistent as panel temperature changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eThermic Current Calibration\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e4.00-6.30A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e25A (switch rating)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eTS EN 60947-4-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperational Frequency\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e50-60Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eUsage Category\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eAC-3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eShort Circuit Protection\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eFixed at 12 x Ie, min. 6kA \/ 400V\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e690V AC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e6kV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMechanical \/ Electrical Life\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e100,000 \/ 100,000 operations (min.)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e360 operations\/hour\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eIP40\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e-5°C to +40°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e0.75-4mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.8Nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e35mm DIN rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from a normal MCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects the cable with a fixed trip curve. The MKS1TM-6.3 protects the motor itself: its thermal trip is set to the motor's running current, it rides through starting inrush, and it adds phase-loss protection that an MCB does not have.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose and set the right range?\u003c\/strong\u003e\u003cbr\u003eRead the full load current from the motor nameplate. If it falls between 4.00A and 6.30A, this is the right switch; set the dial to that value. Below 4.00A use the MKS1TM-4; from 6.30A to 10.0A use the MKS1TM-10.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be mounted outside a panel?\u003c\/strong\u003e\u003cbr\u003eNo. The switch is rated IP40, so it should be fitted on 35mm DIN rail inside an enclosure. EMAS also make an enclosed MKS1TMK version for surface mounting; ask us if you need one.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable sizes does it accept?\u003c\/strong\u003e\u003cbr\u003eThe terminals take 0.75mm² to 4mm² conductors, tightened to 1.8Nm. Auxiliary contacts and other MKS accessories are sold separately.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorkshop machinery\u003c\/strong\u003e - overload and phase-loss protection for saws, drills and grinders with direct-on-line motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePumps and fans\u003c\/strong\u003e - a combined isolator and motor protector for medium-sized pump and fan motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConveyor drives\u003c\/strong\u003e - trips on jams or sustained overload before the motor windings overheat\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed a different range? See the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-4-mks-series-2-50-4-00a-motor-protection-switch\" style=\"color: rgb(43, 0, 255);\"\u003eEMAS MKS1TM-4 (2.50-4.00A)\u003c\/a\u003e\u003c\/strong\u003e or the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-10-mks-series-6-30-10-0a-motor-protection-switch\" style=\"color: rgb(43, 0, 255);\"\u003eEMAS MKS1TM-10 (6.30-10.0A)\u003c\/a\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How is this different from a normal MCB?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"An MCB protects the cable with a fixed trip curve. The MKS1TM-6.3 protects the motor itself: its thermal trip is set to the motor's running current, it rides through starting inrush, and it adds phase-loss protection that an MCB does not have.\"}},{\"@type\":\"Question\",\"name\":\"How do I choose and set the right range?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Read the full load current from the motor nameplate. If it falls between 4.00A and 6.30A, this is the right switch; set the dial to that value. Below 4.00A use the MKS1TM-4; from 6.30A to 10.0A use the MKS1TM-10.\"}},{\"@type\":\"Question\",\"name\":\"Can it be mounted outside a panel?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No. The switch is rated IP40, so it should be fitted on 35mm DIN rail inside an enclosure. EMAS also make an enclosed MKS1TMK version for surface mounting; ask us if you need one.\"}},{\"@type\":\"Question\",\"name\":\"What cable sizes does it accept?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The terminals take 0.75mm² to 4mm² conductors, tightened to 1.8Nm. Auxiliary contacts and other MKS accessories are sold separately.\"}}]}\n\u003c\/script\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57710365933941,"sku":"MKS1TM-6.3","price":61.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/MKS1TM-6_3_20_281_29.jpg?v=1793597024"},{"product_id":"emas-mks1tm-0-40-mks-series-0-25-0-40a-motor-protection-switch","title":"EMAS MKS1TM-0.40 - MKS Series 0.25-0.40A Motor Protection Switch","description":"\u003ch2\u003e\u003cstrong\u003eMotor Protection For The Smallest Motors, 0.25-0.40A\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEMAS MKS1TM-0.40\u003c\/strong\u003e is a DIN rail manual motor protection switch (MPCB) for the smallest motors, drawing between 0.25A and 0.40A at full load, such as instrument fans, small dosing pumps and synchronous drives. It combines adjustable thermal overload, fixed magnetic short-circuit and phase-loss protection in one compact device, and doubles as the motor's local isolator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMPN MKS1TM-0.40\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable thermal overload\u003c\/strong\u003e - set the dial to the motor's nameplate current anywhere from 0.25A to 0.40A\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFixed magnetic short-circuit trip\u003c\/strong\u003e - 6kA breaking capacity\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase deficiency protection\u003c\/strong\u003e - trips if a 3-phase motor loses a phase\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmbient temperature compensated\u003c\/strong\u003e - the trip point stays consistent as panel temperature changes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eDownloads: \u003ca href=\"https:\/\/www.emaselectric.com\/Export\/Datasheet?productCode=MKS1TM-0.40\u0026amp;languageCode=en\" target=\"_blank\" rel=\"noopener\"\u003eEMAS MKS1TM-0.40 datasheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eThermic Current Calibration\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e0.25-0.40A\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eRated Current (Ie)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e25A (switch rating)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eTS EN 60947-4-1\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperational Frequency\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e50-60Hz\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eUsage Category\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eAC-3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eShort Circuit Breaking Capacity\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e6kA\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eInsulation Voltage (Ui)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e690V AC\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eImpulse Withstand Voltage (Uimp)\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e6kV\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMechanical \/ Electrical Life\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e100,000 \/ 100,000 operations (min.)\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Frequency\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e360 operations\/hour\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003eIP40\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e-5°C to +40°C\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003ePollution Degree\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e3\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eCable Section\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e0.75-4mm²\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eScrew Torque\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e1.8Nm\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-xs-6\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-xs-6\"\u003e35mm DIN rail\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow is this different from a normal MCB?\u003c\/strong\u003e\u003cbr\u003eAn MCB protects the cable with a fixed trip curve. The MKS1TM-0.40 protects the motor itself: its thermal trip is set to the motor's running current, it rides through starting inrush, and it adds phase-loss protection that an MCB does not have.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I choose and set the right range?\u003c\/strong\u003e\u003cbr\u003eRead the full load current from the motor nameplate. If it falls between 0.25A and 0.40A, this is the right switch; set the dial to that value. Slightly larger motors need the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-0-63-mks-series-0-40-0-63a-motor-protection-switch\" style=\"color: rgb(43, 0, 255);\"\u003eMKS1TM-0.63 (0.40-0.63A)\u003c\/a\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it be mounted outside a panel?\u003c\/strong\u003e\u003cbr\u003eNo. The switch is rated IP40, so it should be fitted on 35mm DIN rail inside an enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat cable sizes does it accept?\u003c\/strong\u003e\u003cbr\u003eThe terminals take 0.75mm² to 4mm² conductors, tightened to 1.8Nm.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstrument and cooling fans\u003c\/strong\u003e - overload and phase-loss protection for very low-current motors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDosing and sampling pumps\u003c\/strong\u003e - a combined isolator and motor protector in a single DIN rail module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEM machines\u003c\/strong\u003e - compact protection for small auxiliary drives in machine panels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNeed a different range? See the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-0-63-mks-series-0-40-0-63a-motor-protection-switch\" style=\"color: rgb(43, 0, 255);\"\u003eEMAS MKS1TM-0.63 (0.40-0.63A)\u003c\/a\u003e\u003c\/strong\u003e or the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-mks1tm-1-mks-series-0-63-1-00a-motor-protection-switch\" style=\"color: rgb(43, 0, 255);\"\u003eEMAS MKS1TM-1 (0.63-1.00A)\u003c\/a\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\": \"https:\/\/schema.org\", \"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"How is this different from a normal MCB?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"An MCB protects the cable with a fixed trip curve. The MKS1TM-0.40 protects the motor itself: its thermal trip is set to the motor's running current, it rides through starting inrush, and it adds phase-loss protection that an MCB does not have.\"}}, {\"@type\": \"Question\", \"name\": \"How do I choose and set the right range?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Read the full load current from the motor nameplate. If it falls between 0.25A and 0.40A, this is the right switch; set the dial to that value. Slightly larger motors need the MKS1TM-0.63 (0.40-0.63A).\"}}, {\"@type\": \"Question\", \"name\": \"Can it be mounted outside a panel?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. The switch is rated IP40, so it should be fitted on 35mm DIN rail inside an enclosure.\"}}, {\"@type\": \"Question\", \"name\": \"What cable sizes does it accept?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"The terminals take 0.75mm² to 4mm² conductors, tightened to 1.8Nm.\"}}]}\n\u003c\/script\u003e","brand":"EMAS","offers":[{"title":"Default Title","offer_id":57755287224693,"sku":"MKS1TM-0.40","price":61.35,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/MKS1TM-0_40_20_1.jpg?v=1794352816"}],"url":"https:\/\/www.production-automation.co.uk\/de\/collections\/motor-protection-switches.oembed","provider":"Production Automation","version":"1.0","type":"link"}