{"title":"SCADA \u0026 Data Acquisition","description":"\u003ch2\u003e\u003cstrong\u003eLow Cost SCADA \u0026amp; OEE Integration\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eOur Novus automation hardware can be used to pickup existing or new signals using open protocols such as Modbus and MQTT. They can help to build a picture of operational efficiency and compliance.\u003c\/p\u003e\n\u003cp\u003eWe also offer a number of gateway devices that can provide the correct hardware interface for SCADA networks and servers. They can be used with legacy serial networks on RS485.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eData Acquisition With Local Storage At Device Level\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eMany users are concerned with dependency on Cloud data storage. Often these worries centre around reliability and ownership of the data.\u003c\/p\u003e\n\u003cp\u003eNovus dataloggers can be a great solution for acquiring production or environmental data from hardwired sensors or serial devices. One of the key benefits of our dataloggers is they can operate independently. Making installation fast and non-invasive. They can also be interrogated with free software tools from Novus.\u003c\/p\u003e\n\u003cp\u003eSimple systems require no ongoing subscriptions or software licenses. For more demanding applications our dataloggers can now publish to MQTT brokers to share their data with powerful analytic tools.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eBuilt In Cloud Functionality For Remote Storage\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eFor those customers looking to analyse a number of remote data points we can offer hardware with MQTT functionality. These open devices can be incorporated into any MQTT broker, ensuring compatibility with the latest SCADA systems. We recommend the \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/collections\/plc-iot\" title=\"IO Modules\" style=\"color: rgb(43, 0, 255);\"\u003eDigiRail IoT and OEE models\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e for use as sensor gateways. They can publish digital and analogue signals or RS485 registers to an MQTT broker.\u003c\/p\u003e\n\u003cp\u003eNovus offer their own low cost Cloud solution which is suitable for use with Novus Automation devices. It includes a free subscription which is ideal for testing and proof of concept.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eBasic IO Expansion Modules\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eFor simple expansion using RS485 or Ethernet we suggest the \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/collections\/plc-iot\" title=\"IO Modules\" style=\"color: rgb(43, 0, 255);\"\u003eDigiRail Connect or basic IO Modules such as the DigiRail-2A\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e. They can be suitable for PLC or SCADA applications where a small number of additional digital or analogue signals are required.\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003eDeveloping A SCADA Or Analytical System\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThere are many consideration when looking to introduce a new monitoring system. It is important to think about both the current and future number of data points. How the data will be collected at the hardware layer, where it will be stored and how it will be presented. We are happy to talk to you and recommend a suitable partner who can specify and develop a system within your budget.\u003c\/p\u003e\n\u003cp\u003ePlease \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/pages\/contact-us\" title=\"SCADA UK Contact\" style=\"color: rgb(43, 0, 255);\"\u003econtact us\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e with any requests for further information.\u003c\/p\u003e\n\u003ch2\u003eYou May Also Need\u003c\/h2\u003e\n\u003cp\u003eBrowse our full range of \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/collections\/plc-iot\" title=\"IO Modules\" style=\"color: rgb(43, 0, 255);\"\u003eIO Modules\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e and \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/collections\/usb-data-loggers\" title=\"Datalogging Equipment\" style=\"color: rgb(43, 0, 255);\"\u003eDatalogging Equipment\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e.\u003c\/p\u003e","products":[{"product_id":"digirail-oee-wifi-machine-monitoring-2ai-6di-2do-wir","title":"Novus DigiRail OEE WiFi | Wireless IO Module Modbus (2AI \/ 6DI \/ 2DO) MQTT","description":"\u003cp\u003eThe \u003cstrong\u003eDigiRail OEE WiFi\u003c\/strong\u003e is economical machinery or production line monitoring for Overall Equipment Effectiveness (OEE) — hardwired I\/O to MQTT or Modbus, passing data to OEE, DCS or SCADA systems, cloud compatible, and doubling as a Modbus RTU-to-MQTT or Modbus RTU-to-Ethernet gateway. It utilises existing WiFi network infrastructure for data acquisition and logging, avoiding new cable runs.\u003c\/p\u003e\n\u003cp\u003eThe module contains 6 digital inputs, individually configurable to monitor state (On\/Off) or act as counters, plus two analogue inputs and two digital outputs.\u003c\/p\u003e\n\u003cp\u003eInitial configuration in Novus NXperience is an extremely quick process. With a small amount of interface wiring the module can begin gathering data in minutes. This can be passed via MQTT to Novus Cloud or similar services, or sent to existing PLC\/SCADA systems using the Modbus TCP protocol.\u003c\/p\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: rgb(43, 0, 255);\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca title=\"Novus DigiRail OEE Datasheet Download\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/20210506_io_module_iot_application_digirail_oee_datasheet_en.pdf?v=1644302616\" style=\"color: rgb(43, 0, 255);\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" alt=\"\" width=\"32\" height=\"32\"\u003eNovus DigiRail OEE WiFi Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca title=\"Novus DigiRail OEE Manual Download\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/manual_digirail_oee_v12x_c_en.pdf?v=1644302616\" style=\"color: rgb(43, 0, 255);\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003eNovus DigiRail OEE WiFi Manual Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cp\u003eInputs: 6 digital, 2 analogue. Outputs: 2 digital\u003c\/p\u003e\n\u003cp\u003eAnalogue signals: 0-5V, 0-10V, 0-20mA and 4-20mA. Digital signals: NPN, PNP and dry contact\u003c\/p\u003e\n\u003cp\u003eAnalogue input impedance: mA: 15Ω + 1.5V, V: 1MΩ\u003c\/p\u003e\n\u003cp\u003eDigital input: Logical \"0\" \u0026lt;0.5V, Logical \"1\" \u0026gt;3V, max voltage 30V, input impedance 270kΩ, input current @30Vdc typical 0.15mA\u003c\/p\u003e\n\u003cp\u003eMax frequency (square wave): dry contact 10Hz, PNP\/NPN 3kHz. Min pulse duration: dry contact 50ms, PNP\/NPN 150μs\u003c\/p\u003e\n\u003cp\u003eDigital outputs: 2 NPN, max switching current 700mA\u003c\/p\u003e\n\u003cp\u003eAnalogue channel resolution: 15 bits (32000 levels)\u003c\/p\u003e\n\u003cp\u003eCommunication interface: USB, Ethernet 10\/100 Mb\/s (IEEE 802.3u), WiFi 802.11 b\/g\/n 2.4GHz, RS485\u003c\/p\u003e\n\u003cp\u003eSoftware: NXperience\u003c\/p\u003e\n\u003cp\u003ePower supply: 10-36 Vdc. Typical consumption 70mA @24V, max 160mA @12V\u003c\/p\u003e\n\u003cp\u003eOperating conditions: -20 to 60°C, 5-95% RH non-condensing\u003c\/p\u003e\n\u003cp\u003eBattery: CR2032 for internal clock retention. Mounting: DIN rail or screw. Protection: IP20. Enclosure: ABS+PC\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's the difference between this and the Ethernet model?\u003c\/strong\u003e\u003cbr\u003eOnly the network connection — this WiFi version avoids running a new Ethernet cable, useful where the module needs to be sited away from existing network points. Consumption is slightly higher on WiFi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow quickly can I get it collecting data?\u003c\/strong\u003e\u003cbr\u003eInitial configuration in Novus NXperience is fast — with minimal interface wiring the module can begin gathering data within minutes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I still use RS485 devices with the WiFi model?\u003c\/strong\u003e\u003cbr\u003eYes — RS485 terminals are still present, and the module can act as a Modbus RTU-to-Ethernet or Modbus RTU-to-MQTT gateway.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEE \u0026amp; Machine Monitoring\u003c\/strong\u003e — tracks run state and counts for equipment effectiveness reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofit Installations\u003c\/strong\u003e — WiFi connectivity avoids new cable runs to hard-to-reach machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCloud \u0026amp; MQTT Data Logging\u003c\/strong\u003e — passes hardwired I\/O data to Novus Cloud or similar IoT platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What's the difference between this and the Ethernet model?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Only the network connection — this WiFi version avoids running a new Ethernet cable, useful where the module needs to be sited away from existing network points. Consumption is slightly higher on WiFi.\"}},{\"@type\":\"Question\",\"name\":\"How quickly can I get it collecting data?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Initial configuration in Novus NXperience is fast — with minimal interface wiring the module can begin gathering data within minutes.\"}},{\"@type\":\"Question\",\"name\":\"Can I still use RS485 devices with the WiFi model?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — RS485 terminals are still present, and the module can act as a Modbus RTU-to-Ethernet or Modbus RTU-to-MQTT gateway.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":38032211968170,"sku":"8811814460","price":114.87,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/t2-digirail_oee_02_semtampa.png?v=1613290031"},{"product_id":"novus-digirail-oee-ethernet-lan-io-module-modbus-2ai-6di-2do-mqtt","title":"Novus DigiRail OEE Ethernet | LAN IO Module Modbus (2AI \/ 6DI \/ 2DO) MQTT","description":"\u003cp\u003eThe \u003cstrong\u003eDigiRail OEE Ethernet\u003c\/strong\u003e is economical machine monitoring for Overall Equipment Effectiveness (OEE) — hardwired I\/O to MQTT or Modbus, passing data to OEE, DCS or SCADA systems, cloud compatible, and doubling as a Modbus TCP-to-RTU or Modbus RTU-to-MQTT gateway. It utilises existing network infrastructure for data acquisition and logging over your LAN.\u003c\/p\u003e\n\u003cp\u003eThe module contains 6 digital inputs, individually configurable to monitor state (On\/Off) or act as counters, plus two analogue inputs and two digital outputs.\u003c\/p\u003e\n\u003cp\u003eInitial configuration in Novus NXperience is an extremely quick process. With a small amount of interface wiring the module can begin gathering data in minutes. This can be passed via MQTT to Novus Cloud or similar services, or sent to existing PLC\/SCADA systems using the Modbus TCP protocol.\u003c\/p\u003e\n\u003ch3\u003eModbus TCP to RTU Gateway\u003c\/h3\u003e\n\u003cp\u003eThis model can be used as a transparent gateway with no mapping of registers required. It's suitable for reading\/writing registers on RTU Slaves wired to the RS485 terminals — simply communicate via Modbus TCP and the module automatically translates commands.\u003c\/p\u003e\n\u003cp\u003eGateway Mode is a simple method allowing PLCs with Ethernet to communicate with devices such as temperature controllers, instruments and meters — a great solution for networking field devices which are only equipped with RS485 terminals.\u003c\/p\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: rgb(43, 0, 255);\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cp\u003eInputs: 6 digital, 2 analogue. Outputs: 2 digital\u003c\/p\u003e\n\u003cp\u003eAnalogue signals: 0-5V, 0-10V, 0-20mA and 4-20mA. Digital signals: NPN, PNP and dry contact\u003c\/p\u003e\n\u003cp\u003eAnalogue input impedance: mA: 15Ω + 1.5V, V: 1MΩ\u003c\/p\u003e\n\u003cp\u003eDigital input: Logical \"0\" \u0026lt;0.5V, Logical \"1\" \u0026gt;3V, max voltage 30V, input impedance 270kΩ, input current @30Vdc typical 0.15mA\u003c\/p\u003e\n\u003cp\u003eMax frequency (square wave): dry contact 10Hz, PNP\/NPN 3kHz. Min pulse duration: dry contact 50ms, PNP\/NPN 150μs\u003c\/p\u003e\n\u003cp\u003eDigital outputs: 2 NPN, max switching current 700mA\u003c\/p\u003e\n\u003cp\u003eAnalogue channel resolution: 15 bits (32000 levels)\u003c\/p\u003e\n\u003cp\u003eCommunication interface: USB, Ethernet 10\/100 Mb\/s (IEEE 802.3u), RS485\u003c\/p\u003e\n\u003cp\u003eSoftware: NXperience\u003c\/p\u003e\n\u003cp\u003ePower supply: 10-36 Vdc. Typical consumption 50mA @24V, max 120mA @12V\u003c\/p\u003e\n\u003cp\u003eOperating conditions: -20 to 60°C, 5-95% RH non-condensing\u003c\/p\u003e\n\u003cp\u003eBattery: CR2032 for internal clock retention. Mounting: DIN rail or screw. Protection: IP20. Enclosure: ABS+PC\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this connect existing RS485 devices to an Ethernet network?\u003c\/strong\u003e\u003cbr\u003eYes — as a transparent Modbus TCP to RTU gateway, it lets Ethernet-equipped PLCs communicate with RS485-only field devices with no register mapping required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow quickly can I get it collecting data?\u003c\/strong\u003e\u003cbr\u003eInitial configuration in Novus NXperience is fast — with minimal interface wiring the module can begin gathering data within minutes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs there a WiFi version?\u003c\/strong\u003e\u003cbr\u003eYes — see our DigiRail OEE WiFi model if you need wireless rather than wired Ethernet connectivity.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEE \u0026amp; Machine Monitoring\u003c\/strong\u003e — tracks run state and counts for equipment effectiveness reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy Device Integration\u003c\/strong\u003e — bridges RS485-only field devices onto an Ethernet\/Modbus TCP network.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCloud \u0026amp; MQTT Data Logging\u003c\/strong\u003e — passes hardwired I\/O data to Novus Cloud or similar IoT platforms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Can this connect existing RS485 devices to an Ethernet network?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — as a transparent Modbus TCP to RTU gateway, it lets Ethernet-equipped PLCs communicate with RS485-only field devices with no register mapping required.\"}},{\"@type\":\"Question\",\"name\":\"How quickly can I get it collecting data?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Initial configuration in Novus NXperience is fast — with minimal interface wiring the module can begin gathering data within minutes.\"}},{\"@type\":\"Question\",\"name\":\"Is there a WiFi version?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — see our DigiRail OEE WiFi model if you need wireless rather than wired Ethernet connectivity.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":38032226615466,"sku":"8811814420","price":107.14,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/t2-digirail_oee_02_semtampa_80e186b0-0ed1-44ed-bf81-aa74f9632542.png?v=1613290700"},{"product_id":"novus-cloud-basic-1-year","title":"Novus Cloud IoT Platform - Basic 1 Year (Annual Price)","description":"\u003cp\u003e\u003cstrong\u003eNOVUS Cloud\u003c\/strong\u003e is an IoT platform solution for monitoring devices and process data with online visualisation. Ready-to-use with Novus smart IoT devices, it's the perfect choice for customers with low IT infrastructure or requirements to unify data from multiple devices at multiple locations.\u003c\/p\u003e\n\u003cp\u003eNOVUS Cloud can receive information from IoT devices using the MQTT protocol, which is stored in the cloud database and presented to the user in online dashboards. Operation or management staff can also stay aware of the process and any deviations through email or SMS notifications. Hosted on a cloud server, NOVUS Cloud is accessible worldwide from any computer or mobile device.\u003c\/p\u003e\n\u003cp\u003eBasic Plan Includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePaid use for 1 year\u003c\/li\u003e\n\u003cli\u003eLimited to 5 devices\u003c\/li\u003e\n\u003cli\u003e500,000 Data records\u003c\/li\u003e\n\u003cli\u003e1 Month storage\u003c\/li\u003e\n\u003cli\u003e5 Custom dashboards\u003c\/li\u003e\n\u003cli\u003e20 Users\u003c\/li\u003e\n\u003cli\u003e10 Alarms\u003c\/li\u003e\n\u003cli\u003eNo SMS. 250 emails\/month\u003c\/li\u003e\n\u003cli\u003eEquivalent to a 5 minute logging rate for 5 variables\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA free STARTER plan is available when registering at \u003cstrong\u003e\u003ca href=\"https:\/\/iot2.novusautomation.com\/\" style=\"color: rgb(43, 0, 255);\"\u003eiot2.novusautomation.com\u003c\/a\u003e\u003c\/strong\u003e — often the best way to prove and develop your application with no payment commitment. The free plan covers one device with limits on data recording and other features.\u003c\/p\u003e\n\u003cp\u003eCompatible with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e\u003ca title=\"Novus N20K48 IOT Controller\" href=\"https:\/\/www.production-automation.co.uk\/collections\/novus-n20k48\" style=\"color: rgb(43, 0, 255);\"\u003eN20K48 (with WiFi module)\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003ca title=\"LogBox Connect WiFi IOT Data Logger\" href=\"https:\/\/www.production-automation.co.uk\/products\/novus-logbox-connect-wi-fi-data-logger-3-analog-1-digital-inputs-140k-logs\" style=\"color: rgb(43, 0, 255);\"\u003eLogBox WiFi\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003ca title=\"Novus LogBox Connect LTE IOT Data Logger\" href=\"https:\/\/www.production-automation.co.uk\/products\/novus-logbox-connect-lte-sim-data-logger-2-analog-1-digital-inputs-140k-logs\" style=\"color: rgb(43, 0, 255);\"\u003eLogBox LTE\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/digirail-oee-wifi-machine-monitoring-2ai-6di-2do-wir\" style=\"color: rgb(43, 0, 255);\"\u003eDigiRail OEE\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e\u003ca title=\"Novus FieldLogger MQTT Data Logger\" href=\"https:\/\/www.production-automation.co.uk\/collections\/fieldlogger\" style=\"color: rgb(43, 0, 255);\"\u003eFieldLogger Master\u003c\/a\u003e\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eDigiRail IoT\u003c\/li\u003e\n\u003cli\u003eAirGate 4G \/ 3G\u003c\/li\u003e\n\u003cli\u003eTelik Trafo\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNovus Cloud is not compatible with third-party devices — it must be used in conjunction with compatible Novus Automation hardware.\u003c\/p\u003e\n\u003cp\u003eWhen your purchase is processed we'll request an email address to set up your Cloud account, then send a code to authorise the plan. If you'd like a demonstration prior to purchase, please contact us.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eHow much is a Novus Cloud subscription?\u003c\/strong\u003e\u003cbr\u003eWe recommend new users test with the free STARTER package first, covering one device and 180,000 records. This BASIC package covers more users and devices for £140 annually. For advanced users with multiple devices, a CUSTOM plan is most cost-efficient.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow easy is it to install and set up a device?\u003c\/strong\u003e\u003cbr\u003eInitial configuration using NXperience typically takes 30 minutes for a new user. Overall it's realistic that a device can be wired and functional in 1-2 hours, with data visible on Novus Cloud.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I create a Novus Cloud account?\u003c\/strong\u003e\u003cbr\u003eVisit \u003cstrong\u003e\u003ca href=\"https:\/\/iot2.novusautomation.com\/\" style=\"color: rgb(43, 0, 255);\"\u003eiot2.novusautomation.com\u003c\/a\u003e\u003c\/strong\u003e and register with your email address.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow do I add a device to Novus Cloud?\u003c\/strong\u003e\u003cbr\u003eOnce registered, log in via your browser and follow the steps to \"Create A New Device.\" This generates a token to paste into your configuration software (e.g. NXperience), then download the updated configuration file to the device — check the device's communication settings before downloading.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMulti-Site Process Monitoring\u003c\/strong\u003e — unifies data from devices across multiple locations into one dashboard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEE \u0026amp; Machine Monitoring\u003c\/strong\u003e — combines with DigiRail OEE for production line effectiveness tracking.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Alarm Notification\u003c\/strong\u003e — email\/SMS alerts keep operations staff aware of deviations without constant monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"How much is a Novus Cloud subscription?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"We recommend new users test with the free STARTER package first, covering one device and 180,000 records. This BASIC package covers more users and devices for £140 annually. For advanced users with multiple devices, a CUSTOM plan is most cost-efficient.\"}},{\"@type\":\"Question\",\"name\":\"How easy is it to install and set up a device?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Initial configuration using NXperience typically takes 30 minutes for a new user. Overall it's realistic that a device can be wired and functional in 1-2 hours, with data visible on Novus Cloud.\"}},{\"@type\":\"Question\",\"name\":\"How do I create a Novus Cloud account?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Visit iot2.novusautomation.com and register with your email address.\"}},{\"@type\":\"Question\",\"name\":\"How do I add a device to Novus Cloud?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Once registered, log in via your browser and follow the steps to \\\"Create A New Device.\\\" This generates a token to paste into your configuration software (e.g. NXperience), then download the updated configuration file to the device — check the device's communication settings before downloading.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":41111773020330,"sku":"8845000710","price":107.21,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/Card_NOVUS_Cloud_en.png?v=1629275964"},{"product_id":"novus-logbox-connect-wi-fi-data-logger-3-analog-1-digital-inputs-140k-logs","title":"Novus LogBox Connect Wi-Fi Data Logger, 3 Analog + 1 Digital Inputs, 140K Logs MQTT","description":"\u003ch2\u003e\u003cstrong\u003eIndustrial WiFi Data Logger With Universal Inputs \u0026amp; Built In Storage\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eLogBox Wi-Fi\u003c\/strong\u003e works by sampling the inputs and providing a timestamped record of the measured values. These records can be retrieved easily using a free smartphone app or by connecting to a laptop or desktop. Connection to a local WiFi network makes data retrieval simple and fast, well suited to logging instrumentation (flow, pressure, temperature, level), environmental\/climate monitoring, data centres, laboratories, agriculture, distributed and off-grid assets, cold chain, and warehouse applications. The device also has a built-in USB port for initial programming or as a backup to the network connection.\u003c\/p\u003e\n\u003cp\u003eIn the event of a power loss the device can continue to record and retransmit the values once the power supply is re-established. It also includes a built-in temperature sensor for measuring ambient environment, a battery monitor, an onboard buzzer for alarm signalling, a programmable PNP output, a simple mounting bracket with detachable terminal blocks, up to 2 years of battery life if external power is lost, and MQTT\/Cloud compatibility with an open broker.\u003c\/p\u003e\n\u003cp\u003e\u003cimg style=\"float: left;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/selection_guide_novus_-_logbox_-_en.pdf?v=1764830804\" title=\"Novus LogBox Selection Guide\" style=\"color: rgb(43, 0, 255);\"\u003eDownload The Full Selection Guide\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLogBox Wi-Fi\u003c\/strong\u003e can be considered an IoT device with integrated data logger and WiFi connectivity. It allows monitoring and recording of data remotely, in facilities with WiFi infrastructure. The data can be accessed remotely, wirelessly and centralised through a SCADA application, cloud dashboard, or NXperience software. Easy installation and accessibility are highlights of this device.\u003c\/p\u003e\n\u003cp\u003eThe device has three universal analogue inputs and one digital input, which can operate as a pulse counter (flow sensor) or event recorder (opening\/closing doors). LogBox Wi-Fi uses MQTT protocol to publish data into IoT brokers, cloud, or SCADA systems, as well as Modbus TCP protocol to operate as a slave in SCADA systems.\u003c\/p\u003e\n\u003cp\u003eThe device provides uninterrupted recording of data, even during power supply or wireless link failures, thanks to its 2-year autonomy backup battery. LogBox Wi-Fi can be used to help comply with security requirements of FDA Regulation Title 21 CFR Part 11.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eFieldLogger and LogBox products typically have a 7-14 day lead time. If your requirement is urgent, please contact us.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: rgb(43, 0, 255);\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" alt=\"\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca title=\"Novus LogBox Connect Wi-Fi Datasheet Download\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/flyer_logbox_connect_20210923.pdf?v=1648283491\" style=\"color: rgb(43, 0, 255);\"\u003eNovus LogBox Connect WiFi Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca title=\"Novus LogBox Connect Wi-Fi Manual Download\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/manual_logbox_wi-fi_v13x_d_en.pdf?v=1648283491\" style=\"color: rgb(43, 0, 255);\"\u003eNovus LogBox Connect WiFi Manual Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cp\u003eInput signal: 1 digital input, 3 analogue inputs\u003c\/p\u003e\n\u003cp\u003eSignal type: Thermocouples J, K, T, N, E, R, S, B, Pt100, 0-50mV, 0-5V, 0-10V, 0-20mA, 4-20mA\u003c\/p\u003e\n\u003cp\u003eDigital input function: counter of pulses, recorder of events, or starts logger\u003c\/p\u003e\n\u003cp\u003eDigital output: 1 PNP output (electronic switch or alarm)\u003c\/p\u003e\n\u003cp\u003eInternal sensors: NTC for temperature, battery voltage, and external power supply\u003c\/p\u003e\n\u003cp\u003eDisplay: 3 lines with 4½ digits\u003c\/p\u003e\n\u003cp\u003eResolution: analogue inputs 15 bits, counter of pulses 16 bits\u003c\/p\u003e\n\u003cp\u003eMemory capacity: 140,000 records. Recording interval: 1 sec to 18h\u003c\/p\u003e\n\u003cp\u003eVariable record: instantaneous or average\u003c\/p\u003e\n\u003cp\u003eAcquisition trigger: date\/hour, start button, digital input, or by software\u003c\/p\u003e\n\u003cp\u003eAlarms: 8 alarms (two per channel), low and high\u003c\/p\u003e\n\u003cp\u003eInternal buzzer: yes\u003c\/p\u003e\n\u003cp\u003eCommunication interface: WiFi 802.11 b\/g\/n, USB\u003c\/p\u003e\n\u003cp\u003eConfiguration software: NXperience for Windows\u003c\/p\u003e\n\u003cp\u003eCommunication with SCADA or cloud system: MQTT and Modbus TCP protocol\u003c\/p\u003e\n\u003cp\u003ePower supply: 10-30 Vdc\u003c\/p\u003e\n\u003cp\u003eBackup battery: 4 AA alkaline, typical autonomy 2 years (turns off WiFi)\u003c\/p\u003e\n\u003cp\u003eOperating temperature: with power supply -20 to 70°C; with batteries -10 to 50°C\u003c\/p\u003e\n\u003cp\u003eEnclosure protection: IP40. Dimensions: 120 x 100 x 40mm\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's the lead time on this product?\u003c\/strong\u003e\u003cbr\u003eFieldLogger and LogBox products typically have a 7-14 day lead time — contact us if your requirement is urgent.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if I lose power or WiFi connection?\u003c\/strong\u003e\u003cbr\u003eThe device continues recording on backup battery power (up to 2 years autonomy) and retransmits data once the connection or power supply is restored.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this help with FDA compliance?\u003c\/strong\u003e\u003cbr\u003eYes — LogBox Wi-Fi can be used to help comply with security requirements of FDA Regulation Title 21 CFR Part 11.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Chain \u0026amp; Warehouse\u003c\/strong\u003e — remote WiFi logging with uninterrupted recording through power loss.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Centres \u0026amp; Laboratories\u003c\/strong\u003e — environmental and climate monitoring with alarm signalling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed \u0026amp; Off-Grid Assets\u003c\/strong\u003e — long battery autonomy suits remote monitoring locations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What's the lead time on this product?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"FieldLogger and LogBox products typically have a 7-14 day lead time — contact us if your requirement is urgent.\"}},{\"@type\":\"Question\",\"name\":\"What happens if I lose power or WiFi connection?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The device continues recording on backup battery power (up to 2 years autonomy) and retransmits data once the connection or power supply is restored.\"}},{\"@type\":\"Question\",\"name\":\"Can this help with FDA compliance?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — LogBox Wi-Fi can be used to help comply with security requirements of FDA Regulation Title 21 CFR Part 11.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":42743350722730,"sku":"8813005500","price":297.13,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/LogBox-Wi-Fi.png?v=1648283831"},{"product_id":"novus-digirail-2a-analogue-input-module-modbus-rs485","title":"Novus DigiRail-2A | 2 Channel Analogue Input To RS485 Modbus RTU Module (TC, Pt100, mA, V)","description":"\u003cp\u003eThe \u003cstrong\u003eNovus DigiRail-2A\u003c\/strong\u003e (8811100001) turns two analogue sensor signals into Modbus RTU registers on an RS485 network. Each universal input accepts thermocouples, Pt100 RTDs, mV, V or mA, with cold junction compensation, 3-wire Pt100 lead compensation and sensor break detection built in. Temperatures and process signals can then be read directly by a PLC, HMI, SCADA system or data logger acting as Modbus master, without a separate transmitter and analogue input card.\u003c\/p\u003e\n\u003cp\u003eInputs are isolated from the power and communication circuits (1000Vac), which removes ground loops between sensors and the RS485 network and keeps readings stable in electrically noisy panels. With 17-bit resolution and ±0.15% accuracy on Pt100 and process signals, it is one of the most economical ways to add precise analogue inputs to an existing Modbus system. Address, baud rate and input types are set with free DigiConfig software.\u003c\/p\u003e\n\u003ch3\u003eHow It Fits Your System\u003c\/h3\u003e\n\u003cp\u003eSensors wire to the DigiRail-2A on the DIN rail, and a 2-wire RS485 cable links it to your Modbus master. To read it from a PC or laptop, use the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/usb-i485-usb-converter-to-dual-rs485-isolated-ports\" style=\"color: #0000ff; font-weight:bold;\"\u003eNovus USB-i485 converter\u003c\/a\u003e\u003c\/strong\u003e. If you need Ethernet (Modbus TCP), analogue outputs or digital I\/O as well, see the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-connect-ramix-ethernet-io-module-2ai-2ao-4di-3do\" style=\"color: #0000ff; font-weight:bold;\"\u003eDigiRail Connect RAMIX\u003c\/a\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: #0000ff; font-weight:bold;\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cp\u003eOrder code: 8811100001 (DigiRail-2A)\u003c\/p\u003e\n\u003cp\u003eAnalogue inputs: 2, universal, programmable for thermocouple J, K, T, E, N, R, S, B; Pt100; mV; V; mA\u003c\/p\u003e\n\u003cp\u003eResolution: 17 bits\u003c\/p\u003e\n\u003cp\u003eAccuracy (@25°C): Pt100, mV, V, mA ±0.15% of full scale; thermocouples ±0.25% of full scale\u003c\/p\u003e\n\u003cp\u003eSampling rate (1 input): 10Hz for mV, V and mA; 5Hz for thermocouples and Pt100\u003c\/p\u003e\n\u003cp\u003eCold junction compensation: 1°C at 25°C, ±0.05°C\/°C. Pt100 3-wire lead compensation\u003c\/p\u003e\n\u003cp\u003eSensor break detection: thermocouples, Pt100 and mV\u003c\/p\u003e\n\u003cp\u003eTemperature effect: 0.003% of full scale\/°C\u003c\/p\u003e\n\u003cp\u003eIsolation: 1000Vac between inputs and power\/communication\u003c\/p\u003e\n\u003cp\u003eCommunication: 2-wire RS485, Modbus RTU slave, configurable address and baud rate (1,200 to 115,200bps)\u003c\/p\u003e\n\u003cp\u003eIndicators: LEDs for communication and status, key to reset communication parameters to factory default\u003c\/p\u003e\n\u003cp\u003ePower supply: 10-35 Vdc, 50mA max\u003c\/p\u003e\n\u003cp\u003eConfiguration software: DigiConfig (free Windows download)\u003c\/p\u003e\n\u003cp\u003eDimensions: 72 x 78 x 19mm. Mounting: 35mm DIN rail. Working temperature: 0 to 70°C\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat signals can the DigiRail-2A read?\u003c\/strong\u003e\u003cbr\u003eEach of the two inputs can be set independently for a thermocouple (J, K, T, E, N, R, S or B), a Pt100 RTD, or a mV, V or mA process signal, so one module can read a temperature sensor and a 4-20mA transmitter side by side.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat do I need to read the values?\u003c\/strong\u003e\u003cbr\u003eA Modbus RTU master on RS485, such as a PLC, HMI, SCADA system or data logger. The DigiRail-2A is a slave, so it responds to register reads from the master.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I put several modules on one RS485 network?\u003c\/strong\u003e\u003cbr\u003eYes. Each module has its own configurable Modbus address, so several can share one 2-wire RS485 bus alongside other Modbus instruments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen should I choose DigiRail Connect instead?\u003c\/strong\u003e\u003cbr\u003eChoose DigiRail Connect RAMIX if you need Ethernet (Modbus TCP), analogue outputs or digital I\/O in the same module. For analogue inputs on RS485 only, the DigiRail-2A is the simpler, lower-cost option.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature monitoring\u003c\/strong\u003e — brings oven, kiln, tank and process temperatures into SCADA or a data logger.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC analogue expansion\u003c\/strong\u003e — adds isolated analogue inputs to a PLC with spare RS485 instead of buying an analogue card.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC \u0026amp; BMS\u003c\/strong\u003e — integrates duct, water and pressure sensor signals onto a Modbus building network.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What signals can the DigiRail-2A read?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Each of the two inputs can be set independently for a thermocouple (J, K, T, E, N, R, S or B), a Pt100 RTD, or a mV, V or mA process signal, so one module can read a temperature sensor and a 4-20mA transmitter side by side.\"}},{\"@type\":\"Question\",\"name\":\"What do I need to read the values?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A Modbus RTU master on RS485, such as a PLC, HMI, SCADA system or data logger. The DigiRail-2A is a slave, so it responds to register reads from the master.\"}},{\"@type\":\"Question\",\"name\":\"Can I put several modules on one RS485 network?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Each module has its own configurable Modbus address, so several can share one 2-wire RS485 bus alongside other Modbus instruments.\"}},{\"@type\":\"Question\",\"name\":\"When should I choose DigiRail Connect instead?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Choose DigiRail Connect RAMIX if you need Ethernet (Modbus TCP), analogue outputs or digital I\/O in the same module. For analogue inputs on RS485 only, the DigiRail-2A is the simpler, lower-cost option.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":44540089172138,"sku":"8811100001","price":92.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/DigiRail_2A.png?v=1679810867"},{"product_id":"novus-digirail-connect-dmix-ethernet-io-module-8di-8do","title":"Novus DigiRail Connect DMIX | Ethernet IO Module Modbus TCP\/RTU (8DI \/ 8DO)","description":"\u003cp\u003eThe \u003cstrong\u003eNovus DigiRail Connect DMIX 8DI \/ 8DO\u003c\/strong\u003e (8811612420) adds 8 digital inputs and 8 PNP transistor outputs to almost any PLC, SCADA or data logging system, over Ethernet (Modbus TCP) or RS485 (Modbus RTU). Inputs accept PNP, NPN or dry contact signals and can be configured as pulse counters, and outputs can be set for pulse operation, making it a compact way to add discrete I\/O wherever a controller has run out of points.\u003c\/p\u003e\n\u003cp\u003eEvery DigiRail Connect model has Ethernet, RS485 and Micro USB on board. It works as a Modbus RTU slave on an existing RS485 network or as a Modbus TCP server on Ethernet, and can act as a transparent Modbus TCP to RTU gateway, so an Ethernet PLC or SCADA system can read RS485 instruments wired to its terminals with no register mapping. Configuration and I\/O testing use free Novus NXperience software over USB.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLead time:\u003c\/strong\u003e made to order by Novus, typically 1–2 weeks to dispatch.\u003c\/p\u003e\n\u003ch3\u003eDigiRail Connect Range\u003c\/h3\u003e\n\u003cp\u003eAll four DigiRail Connect models share the same Ethernet\/RS485 hardware and software. Choose by the I\/O mix you need:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDMIX 8DI \/ 8DO (8811612420)\u003c\/strong\u003e — this model: 8 digital inputs, 8 PNP transistor outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-connect-dmix-ethernet-io-module-8di-4-relay\" style=\"color: #0000ff; font-weight:bold;\"\u003eDMIX 8DI \/ 4 Relay (8811612440)\u003c\/a\u003e\u003c\/strong\u003e — 8 digital inputs, 4 relay outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-connect-ramix-ethernet-io-module-2ai-2ao-4di-3do\" style=\"color: #0000ff; font-weight:bold;\"\u003eRAMIX 2AI \/ 2AO \/ 4DI \/ 3DO (8811611420)\u003c\/a\u003e\u003c\/strong\u003e — 2 universal analogue inputs, 2 analogue outputs, 4 digital inputs, 3 PNP outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-connect-ramix-ethernet-io-module-2ai-2ao-4di-2-relay\" style=\"color: #0000ff; font-weight:bold;\"\u003eRAMIX 2AI \/ 2AO \/ 4DI \/ 2 Relay (8811611440)\u003c\/a\u003e\u003c\/strong\u003e — as above with 2 relay outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOnly need analogue inputs on RS485? The lower-cost \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-2a-analogue-input-module-modbus-rs485\" style=\"color: #0000ff; font-weight:bold;\"\u003eNovus DigiRail-2A\u003c\/a\u003e\u003c\/strong\u003e converts two thermocouple, Pt100, mV, V or mA signals to Modbus RTU.\u003c\/p\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: #0000ff; font-weight:bold;\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" alt=\"PDF\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/ethernet_io_module_digirailconnect_20191010_fl_en.pdf?v=1707947248\" title=\"Novus DigiRail Connect Datasheet Download\" style=\"color: #0000ff; font-weight:bold;\"\u003eNovus DigiRail Connect Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" alt=\"PDF\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/manual_digirail_connect_v10x_h_en.pdf?v=1707946946\" title=\"Novus DigiRail Connect Manual Download\" style=\"color: #0000ff; font-weight:bold;\"\u003eNovus DigiRail Connect Manual Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cp\u003eOrder code: 8811612420 (DigiRail Connect DMIX 8DI \/ 8DO ETH)\u003c\/p\u003e\n\u003cp\u003eDigital inputs: 8, PNP, NPN or dry contact, configurable counter function\u003c\/p\u003e\n\u003cp\u003eDigital outputs: 8, PNP transistor, 200mA max load per output, 6-30 Vdc switching, configurable pulse function\u003c\/p\u003e\n\u003cp\u003eCommunication: Ethernet 10\/100 Mb\/s (IEEE 802.3u), RS485, Micro USB\u003c\/p\u003e\n\u003cp\u003eProtocols: Modbus TCP server, Modbus RTU slave, transparent Modbus TCP to RTU gateway\u003c\/p\u003e\n\u003cp\u003eConfiguration software: Novus NXperience (free, via USB)\u003c\/p\u003e\n\u003cp\u003ePower supply: 10-36 Vdc, 5W max (20mA typical)\u003c\/p\u003e\n\u003cp\u003eOperating conditions: -20 to 60°C, 5-95% RH non-condensing\u003c\/p\u003e\n\u003cp\u003eEnclosure: ABS+PC, 35mm DIN rail mounting\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShould I choose this 8DO model or the DMIX 4 Relay model?\u003c\/strong\u003e\u003cbr\u003eThe 8DO model has PNP transistor outputs (up to 200mA each) for driving PLC inputs, interposing relays and indicator lamps. If you need volt-free contacts or to switch AC loads, the DMIX 8DI \/ 4 Relay model is the better fit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the digital inputs count pulses?\u003c\/strong\u003e\u003cbr\u003eYes. Each input can be configured as a counter in NXperience, which suits flow meter pulses, production counts and run-hour monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it bridge RS485 devices onto Ethernet?\u003c\/strong\u003e\u003cbr\u003eYes. In gateway mode it passes Modbus TCP requests to RTU slaves wired to its RS485 terminals with no register mapping, so an Ethernet PLC can read existing RS485 controllers and meters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if communication is lost?\u003c\/strong\u003e\u003cbr\u003eA configurable watchdog drives the outputs to a defined safe state if the Modbus master stops communicating.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMachine \u0026amp; line monitoring\u003c\/strong\u003e — counts parts and reads sensor and limit switch status for OEE or production reporting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePLC I\/O expansion\u003c\/strong\u003e — adds 16 discrete points to a PLC over Ethernet without a rack expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding services\u003c\/strong\u003e — reads plant status contacts and switches pumps and fans through interposing relays on BMS networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Should I choose this 8DO model or the DMIX 4 Relay model?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The 8DO model has PNP transistor outputs (up to 200mA each) for driving PLC inputs, interposing relays and indicator lamps. If you need volt-free contacts or to switch AC loads, the DMIX 8DI \/ 4 Relay model is the better fit.\"}},{\"@type\":\"Question\",\"name\":\"Can the digital inputs count pulses?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Each input can be configured as a counter in NXperience, which suits flow meter pulses, production counts and run-hour monitoring.\"}},{\"@type\":\"Question\",\"name\":\"Can it bridge RS485 devices onto Ethernet?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. In gateway mode it passes Modbus TCP requests to RTU slaves wired to its RS485 terminals with no register mapping, so an Ethernet PLC can read existing RS485 controllers and meters.\"}},{\"@type\":\"Question\",\"name\":\"What happens if communication is lost?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A configurable watchdog drives the outputs to a defined safe state if the Modbus master stops communicating.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":44540196192426,"sku":"8811612420","price":175.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/t2-modulo_io_ethernet_digirail_connect_dmix_01.jpg?v=1679813268"},{"product_id":"novus-fieldlogger-512k-ethernet-hmi-2xrs485-master-slave-data-logger-24v-supply-copy","title":"Novus FieldLogger - 512K Ethernet + HMI, 2xRS485 Master\/Slave Data Logger (24V) MQTT","description":"\u003cp\u003eThis advanced \u003cstrong\u003eFieldLogger\u003c\/strong\u003e model can function as an RS485 Master and comes with an Ethernet port, complete assembly with HMI attached, and USB host for downloading logs to a USB memory stick. Data can also be accessed via Mini USB using free NXperience software. Dual RS485 interface supports up to 32 Modbus RTU Slave and Master channels, so the device can gather data from hardwired universal inputs or networked devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWe are experienced in the configuration and commissioning of the FieldLogger product line and can offer initial training and ongoing technical support.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eFieldLogger is a simple to use industrial grade datalogger, covering a wide range of applications such as monitoring of industrial processes, cold chain\/logistics, data centres, building management, and renewable energy. No software purchases or ongoing subscriptions required.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eIt offers fast, no-code setup with free NXperience software, 512K internal memory expandable with an SD card, up to 100 channels logged simultaneously, 8 universal inputs supporting multiple sensor types, 8 digital I\/O and 2 relay outputs, networked sensor logging (64 registers via RS485 or Ethernet), logic operations and virtual channels, up to 32 configurable alarms, and a Mini USB interface for programming, monitoring, and download. Power supply: 24V DC.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eFieldLogger and LogBox products are typically available on 7-10 days lead time. If your requirement is urgent, please contact us.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: rgb(43, 0, 255);\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" alt=\"\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/6100082_catalogue_fieldlogger_202011_en.pdf?v=1643610008\" title=\"Novus FieldLogger Datasheet Download\" style=\"color: rgb(43, 0, 255);\"\u003eNovus FieldLogger - Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/manual_fieldlogger_v17x_a_en.pdf?v=1644561993\" title=\"Novus FieldLogger Manual Download\" style=\"color: rgb(43, 0, 255);\"\u003eNovus FieldLogger - Manual Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eManual note: the hardware, wiring and specification sections of the manual remain current. Where the manual refers to the FieldLogger Configurator, use NXperience instead.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFieldLogger\u003c\/strong\u003e is a versatile, powerful, and cost-effective data logger handling analogue, digital, and other types of variables with high resolution and speed — high performance and high connectivity equipment, yet easy to configure and operate.\u003c\/p\u003e\n\u003cp\u003eIt has 8 configurable analogue inputs that can read thermocouples, Pt100, Pt1000, voltage and current signals. It also has 2 relay outputs and 8 digital ports, individually configurable as inputs or outputs.\u003c\/p\u003e\n\u003cp\u003eUp to 128 mathematical channels can be used to perform operations on the measured values. Up to 32 alarm events can be detected, allowing output activations, emails, and SNMP traps.\u003c\/p\u003e\n\u003cp\u003eIts RS485 interface can operate as a Modbus RTU master or slave. As a master, it can read and log up to 64 external channels. It has a 10\/100 Mbps Ethernet interface allowing access through a browser (HTTP), FTP (client and server), email sending (SMTP), SNMP, and Modbus TCP.\u003c\/p\u003e\n\u003cp\u003eFieldLogger has one USB interface for connecting to a computer (configuration, monitoring, data download) and another USB port for a flash drive for data retrieval. The 512k logging basic memory can be greatly expanded with an SD card.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e all FieldLogger models are now configured with Novus's free \u003cstrong\u003eNXperience\u003c\/strong\u003e software, which replaces the legacy FieldLogger Configurator — no separate configurator is required. NXperience connects via USB, Ethernet or RS485 and provides set-up, online monitoring, logged data download, export to spreadsheets and other formats, and support for the latest MQTT features.\u003c\/p\u003e\n\u003ch3\u003eCompare FieldLogger Models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlave, RS485 only\u003c\/strong\u003e — \u003ca href=\"\/products\/novus-fieldlogger-512k-rs485-24v-slave-data-logger\" style=\"color: rgb(43, 0, 255);\"\u003e24V AC\/DC\u003c\/a\u003e | \u003ca href=\"\/products\/novus-fieldlogger-512k-rs485-slave-data-logger-ac-supply\" style=\"color: rgb(43, 0, 255);\"\u003e100-240 VAC\u003c\/a\u003e: entry model, Modbus RTU Slave, no Ethernet and no HMI support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet, 2xRS485 Master\/Slave\u003c\/strong\u003e — \u003ca href=\"\/products\/novus-fieldlogger-ethernet-hmi-2xrs485-master-slave-data-logger-24v-supply\" style=\"color: rgb(43, 0, 255);\"\u003e24V\u003c\/a\u003e | \u003ca href=\"\/products\/novus-fieldlogger-ethernet-hmi-2xrs485-master-slave-data-logger-ac-supply\" style=\"color: rgb(43, 0, 255);\"\u003e230V\u003c\/a\u003e: adds Ethernet, Modbus Master and MQTT; an HMI display can be fitted now or later.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet + HMI, factory assembled\u003c\/strong\u003e — 24V (this model) | \u003ca href=\"\/products\/novus-fieldlogger-512k-ethernet-hmi-2xrs485-master-slave-data-logger-ac-supply-copy\" style=\"color: rgb(43, 0, 255);\"\u003e230V\u003c\/a\u003e: as above, supplied with the colour HMI display already fitted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/novus-fieldlogger-hmi\" style=\"color: rgb(43, 0, 255);\"\u003eFieldLogger HMI Accessory\u003c\/a\u003e\u003c\/strong\u003e — clip-on or remote-mount colour display for the Ethernet models.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhy choose the 24V version over the mains model?\u003c\/strong\u003e\u003cbr\u003eFor control panels already running 12-24V rails, off-grid installations, or mobile\/vehicle-mounted equipment where mains power isn't available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it operate as a Modbus Master to collect data from other devices?\u003c\/strong\u003e\u003cbr\u003eYes — with dual RS485 interfaces it can act as Modbus RTU Master or Slave, reading and logging up to 64 external registers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support MQTT?\u003c\/strong\u003e\u003cbr\u003eYes — FieldLogger is configured with NXperience, which supports the latest MQTT features for cloud and IoT broker connectivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I still need the FieldLogger Configurator software?\u003c\/strong\u003e\u003cbr\u003eNo — the FieldLogger Configurator has been replaced. All FieldLogger models are now set up, monitored and downloaded using Novus's free NXperience software, connected via USB, Ethernet or RS485.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-Grid \u0026amp; Mobile Data Logging\u003c\/strong\u003e — 24V supply for remote or vehicle-mounted monitoring installations, with local HMI feedback.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Process Monitoring\u003c\/strong\u003e — 8 universal inputs plus networked Modbus channels in one system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding Management \u0026amp; Renewable Energy\u003c\/strong\u003e — Ethernet connectivity for SCADA and browser-based access.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Why choose the 24V version over the mains model?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"For control panels already running 12-24V rails, off-grid installations, or mobile\/vehicle-mounted equipment where mains power isn't available.\"}},{\"@type\":\"Question\",\"name\":\"Can it operate as a Modbus Master to collect data from other devices?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — with dual RS485 interfaces it can act as Modbus RTU Master or Slave, reading and logging up to 64 external registers.\"}},{\"@type\":\"Question\",\"name\":\"Does it support MQTT?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — FieldLogger is configured with NXperience, which supports the latest MQTT features for cloud and IoT broker connectivity.\"}},{\"@type\":\"Question\",\"name\":\"Do I still need the FieldLogger Configurator software?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No — the FieldLogger Configurator has been replaced. All FieldLogger models are now set up, monitored and downloaded using Novus's free NXperience software, connected via USB, Ethernet or RS485.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":53582478311797,"sku":"8812191904","price":941.21,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/data_logger_induatrial_multicanais_fieldlogger_02_9a84d89d-9532-4f96-9883-72967f3895c6.png?v=1728798211"},{"product_id":"novus-fieldlogger-512k-ethernet-hmi-2xrs485-master-slave-data-logger-ac-supply-copy","title":"Novus FieldLogger - 512K Ethernet + HMI, 2xRS485 Master\/Slave Data Logger (230V) MQTT","description":"\u003cp\u003eThis advanced \u003cstrong\u003eFieldLogger\u003c\/strong\u003e model can function as an RS485 Master and comes with an Ethernet port, complete assembly with HMI attached, and USB host for downloading logs to a USB memory stick. Data can also be accessed via Mini USB using free NXperience software. Dual RS485 interface supports up to 32 Modbus RTU Slave and Master channels, so the device can gather data from hardwired universal inputs or networked devices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWe are experienced in the configuration and commissioning of the FieldLogger product line and can offer initial training and ongoing technical support.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eFieldLogger is a simple to use industrial grade datalogger, covering a wide range of applications such as monitoring of industrial processes, cold chain\/logistics, data centres, building management, and renewable energy. No software purchases or ongoing subscriptions required.\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003eIt offers fast, no-code setup with free NXperience software, 512K internal memory expandable with an SD card, up to 100 channels logged simultaneously, 8 universal inputs supporting multiple sensor types, 8 digital I\/O and 2 relay outputs, networked sensor logging (64 registers via RS485 or Ethernet), logic operations and virtual channels, up to 32 configurable alarms, and a Mini USB interface for programming, monitoring, and download. Power supply: 100-240 VAC.\u003c\/p\u003e\n\u003cblockquote\u003e\n\u003cp\u003e\u003cem\u003e\u003cstrong\u003eFieldLogger and LogBox products are typically available on 7-10 days lead time. If your requirement is urgent, please contact us.\u003c\/strong\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/blockquote\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: rgb(43, 0, 255);\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca title=\"Novus FieldLogger Datasheet Download\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/6100082_catalogue_fieldlogger_202011_en.pdf?v=1643610008\" style=\"color: rgb(43, 0, 255);\"\u003eNovus FieldLogger - Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca title=\"Novus FieldLogger Manual Download\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/manual_fieldlogger_v17x_a_en.pdf?v=1644561993\" style=\"color: rgb(43, 0, 255);\"\u003eNovus FieldLogger - Manual Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eManual note: the hardware, wiring and specification sections of the manual remain current. Where the manual refers to the FieldLogger Configurator, use NXperience instead.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFieldLogger\u003c\/strong\u003e is a versatile, powerful, and cost-effective data logger handling analogue, digital, and other types of variables with high resolution and speed — high performance and high connectivity equipment, yet easy to configure and operate.\u003c\/p\u003e\n\u003cp\u003eIt has 8 configurable analogue inputs that can read thermocouples, Pt100, Pt1000, voltage and current signals. It also has 2 relay outputs and 8 digital ports, individually configurable as inputs or outputs.\u003c\/p\u003e\n\u003cp\u003eUp to 128 mathematical channels can be used to perform operations on the measured values. Up to 32 alarm events can be detected, allowing output activations, emails, and SNMP traps.\u003c\/p\u003e\n\u003cp\u003eIts RS485 interface can operate as a Modbus RTU master or slave. As a master, it can read and log up to 64 external channels. It has a 10\/100 Mbps Ethernet interface allowing access through a browser (HTTP), FTP (client and server), email sending (SMTP), SNMP, and Modbus TCP.\u003c\/p\u003e\n\u003cp\u003eFieldLogger has one USB interface for connecting to a computer (configuration, monitoring, data download) and another USB port for a flash drive for data retrieval. The 512k logging basic memory can be greatly expanded with an SD card.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration:\u003c\/strong\u003e all FieldLogger models are now configured with Novus's free \u003cstrong\u003eNXperience\u003c\/strong\u003e software, which replaces the legacy FieldLogger Configurator — no separate configurator is required. NXperience connects via USB, Ethernet or RS485 and provides set-up, online monitoring, logged data download, export to spreadsheets and other formats, and support for the latest MQTT features.\u003c\/p\u003e\n\u003ch3\u003eCompare FieldLogger Models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlave, RS485 only\u003c\/strong\u003e — \u003ca href=\"\/products\/novus-fieldlogger-512k-rs485-24v-slave-data-logger\" style=\"color: rgb(43, 0, 255);\"\u003e24V AC\/DC\u003c\/a\u003e | \u003ca href=\"\/products\/novus-fieldlogger-512k-rs485-slave-data-logger-ac-supply\" style=\"color: rgb(43, 0, 255);\"\u003e100-240 VAC\u003c\/a\u003e: entry model, Modbus RTU Slave, no Ethernet and no HMI support.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet, 2xRS485 Master\/Slave\u003c\/strong\u003e — \u003ca href=\"\/products\/novus-fieldlogger-ethernet-hmi-2xrs485-master-slave-data-logger-24v-supply\" style=\"color: rgb(43, 0, 255);\"\u003e24V\u003c\/a\u003e | \u003ca href=\"\/products\/novus-fieldlogger-ethernet-hmi-2xrs485-master-slave-data-logger-ac-supply\" style=\"color: rgb(43, 0, 255);\"\u003e230V\u003c\/a\u003e: adds Ethernet, Modbus Master and MQTT; an HMI display can be fitted now or later.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEthernet + HMI, factory assembled\u003c\/strong\u003e — \u003ca href=\"\/products\/novus-fieldlogger-512k-ethernet-hmi-2xrs485-master-slave-data-logger-24v-supply-copy\" style=\"color: rgb(43, 0, 255);\"\u003e24V\u003c\/a\u003e | 230V (this model): as above, supplied with the colour HMI display already fitted.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"\/products\/novus-fieldlogger-hmi\" style=\"color: rgb(43, 0, 255);\"\u003eFieldLogger HMI Accessory\u003c\/a\u003e\u003c\/strong\u003e — clip-on or remote-mount colour display for the Ethernet models.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need ongoing software subscriptions?\u003c\/strong\u003e\u003cbr\u003eNo — configuration, monitoring, and data download use the free NXperience software with no software purchases or subscriptions required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it operate as a Modbus Master to collect data from other devices?\u003c\/strong\u003e\u003cbr\u003eYes — with dual RS485 interfaces it can act as Modbus RTU Master or Slave, reading and logging up to 64 external registers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it support MQTT?\u003c\/strong\u003e\u003cbr\u003eYes — FieldLogger is now configured with NXperience, which supports the latest MQTT features for cloud and IoT broker connectivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I still need the FieldLogger Configurator software?\u003c\/strong\u003e\u003cbr\u003eNo — the FieldLogger Configurator has been replaced. All FieldLogger models are now set up, monitored and downloaded using Novus's free NXperience software, connected via USB, Ethernet or RS485.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Process Monitoring\u003c\/strong\u003e — 8 universal inputs plus networked Modbus channels in one system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold Chain \u0026amp; Data Centres\u003c\/strong\u003e — alarm-driven logging with email\/SNMP notifications.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding Management \u0026amp; Renewable Energy\u003c\/strong\u003e — Ethernet connectivity for SCADA and browser-based access.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Do I need ongoing software subscriptions?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No — configuration, monitoring, and data download use the free NXperience software with no software purchases or subscriptions required.\"}},{\"@type\":\"Question\",\"name\":\"Can it operate as a Modbus Master to collect data from other devices?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — with dual RS485 interfaces it can act as Modbus RTU Master or Slave, reading and logging up to 64 external registers.\"}},{\"@type\":\"Question\",\"name\":\"Does it support MQTT?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — FieldLogger is now configured with NXperience, which supports the latest MQTT features for cloud and IoT broker connectivity.\"}},{\"@type\":\"Question\",\"name\":\"Do I still need the FieldLogger Configurator software?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No — the FieldLogger Configurator has been replaced. All FieldLogger models are now set up, monitored and downloaded using Novus's free NXperience software, connected via USB, Ethernet or RS485.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":53582478606709,"sku":"8812191900","price":931.21,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/data_logger_induatrial_multicanais_fieldlogger_02_9a84d89d-9532-4f96-9883-72967f3895c6.png?v=1728798211"},{"product_id":"novus-airgate-wireless-modbus-gateway","title":"Novus Airgate Wireless Gateway (Modbus, RS485)","description":"\u003ch2\u003e\u003cstrong\u003eWireless RS485 Modbus RTU Gateway\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAirGate\u003c\/strong\u003e is a great solution if the RS485 network requires wireless connectivity — for example, where it's not feasible to route wires over long distances or through inaccessible areas. It can be used to rapidly expand an existing RS485 network.\u003c\/p\u003e\n\u003cp\u003eAirGate is a universal device, not restricted to Novus Automation products, and can be used with any RS485 device communicating via Modbus. Note that two or more AirGate devices are required to create the network.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/AirGate.png?v=1743179727\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eAs an extender of the Modbus RS485 network, it offers flexibility and scalability for various networks inside facilities, with long-range wireless communication reaching up to 3200 feet (1000m).\u003c\/p\u003e\n\u003cp\u003eOperating through Novus's own NOVUS-Air wireless network protocol (802.15.4), AirGate-Modbus is independent from the customer's IT infrastructure.\u003c\/p\u003e\n\u003cp\u003eCommunication has secure data traffic, ensured by 128-bit encryption, and uses available frequency bands with less interference, providing stability and reliability in the communication link. Easy installation, configuration, and diagnostics make AirGate-Modbus an outstanding product for field commissioning.\u003c\/p\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: rgb(43, 0, 255);\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/airgate_modbus_gateway_wireless_en.pdf?v=1743179500\" title=\"Novus AirGate Datasheet Download\" style=\"color: rgb(43, 0, 255);\"\u003eNovus AirGate Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/manual_airgate-modbus_v10x_g_en.pdf?v=1743179502\" title=\"Novus AirGate Manual Download\" style=\"color: rgb(43, 0, 255);\"\u003eNovus AirGate Manual Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cp\u003eCommunication Interfaces: Micro-USB Type-B, RS485, IEEE802.15.4. Protocols: Modbus RTU and NOVUS-Air\u003c\/p\u003e\n\u003cp\u003eNetwork Topology: Point-to-point, star, and tree\u003c\/p\u003e\n\u003cp\u003eWireless: ISM 2.4GHz, DSSS, OQPSK, 15 channels, Tx Power 20dBm, Sensitivity -96dBm, Line-of-Sight Range 1000m\u003c\/p\u003e\n\u003cp\u003eSecurity: AES-CBC-128 Encryption. Modes of Operation: RS485-Master, USB-Master, Multi-Master, RS485-Slave\u003c\/p\u003e\n\u003cp\u003eFirmware Upgrade: Yes, via USB. Power Supply: 10-30 Vdc\u003c\/p\u003e\n\u003cp\u003eConfiguration: Yes, via USB with DigiConfig. Housing: Injected PA66\u003c\/p\u003e\n\u003cp\u003eDimensions: 99.5 x 114 x 17.5mm + antenna 105mm\u003c\/p\u003e\n\u003cp\u003eOperating Range: -10 to 70°C, humidity 80% up to 30°C. Protection Rating: IP20. Electric Protection: Reverse Polarity\u003c\/p\u003e\n\u003cp\u003eCertifications: CE, FCC, ANATEL (01818-11-07089)\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need one AirGate or two?\u003c\/strong\u003e\u003cbr\u003eTwo or more AirGate devices are required to create the wireless network — one alone can't bridge a link.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this work with non-Novus RS485 devices?\u003c\/strong\u003e\u003cbr\u003eYes — AirGate is a universal device and works with any RS485 device communicating via Modbus, not just Novus products.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow far can the wireless link reach?\u003c\/strong\u003e\u003cbr\u003eUp to 3200 feet (1000m) line-of-sight, using Novus's own NOVUS-Air 802.15.4 wireless protocol.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Distance RS485 Links\u003c\/strong\u003e — replaces cable runs where wiring isn't feasible over distance or through obstacles.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Expansion\u003c\/strong\u003e — rapidly extends an existing RS485 network without new cabling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField Commissioning\u003c\/strong\u003e — easy installation and diagnostics suit fast deployment on site.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Do I need one AirGate or two?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Two or more AirGate devices are required to create the wireless network — one alone can't bridge a link.\"}},{\"@type\":\"Question\",\"name\":\"Does this work with non-Novus RS485 devices?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — AirGate is a universal device and works with any RS485 device communicating via Modbus, not just Novus products.\"}},{\"@type\":\"Question\",\"name\":\"How far can the wireless link reach?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Up to 3200 feet (1000m) line-of-sight, using Novus's own NOVUS-Air 802.15.4 wireless protocol.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":55206021431669,"sku":"8816041310","price":241.03,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/Gateway_AirGate-Modbus_MicroUSB01.png?v=1743178706"},{"product_id":"novus-logbox-connect-lte-sim-data-logger-2-analog-1-digital-inputs-140k-logs","title":"Novus LogBox Connect LTE (SIM) Data Logger, 2 Analog + 1 Digital Inputs, 140K Logs MQTT","description":"\u003ch2\u003e\u003cstrong\u003eIndustrial Remote Data Logger With Universal Inputs \u0026amp; MQTT\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eNovus \u003cstrong\u003eLogBox Connect LTE\u003c\/strong\u003e data logger captures timestamped readings from 2 analogue and 1 digital input. Built for distributed assets, off-grid and mobile applications, it transmits data via cellular networks using standard SIM cards. Ideal for flow, pressure, temperature, level, and environmental monitoring. Supports MQTT for Publisher\/Subscriber modes and integrates with Novus Cloud or generic brokers for online data access.\u003c\/p\u003e\n\u003cp\u003eRecords can be retrieved via NXperience Desktop (USB), NXperience Mobile app, or remotely via MQTT to Novus Cloud or any other broker (Mosquitto, EMQX, HiveMQ, AWS IoT Core, Azure IoT Hub, Google Cloud IoT, etc).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cem\u003eNovus Cloud STARTER is free for 180,000 records per year (approx. 3 variables logged every 10 minutes). The BASIC plan with higher limits is £140 annually.\u003c\/em\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn the event of a power loss the device can continue to record and transmit values, or — to prolong battery operation — transmission can be paused until reconnection of the external supply.\u003c\/p\u003e\n\u003cp\u003eLogBox Connect LTE includes built-in temperature sensing, battery and power supply monitoring. It features a programmable PNP output and offers flexible 1-second to 12-hour recording intervals, with 10 configurable alarms supporting digital output, SMS, and MQTT triggers.\u003c\/p\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: rgb(43, 0, 255);\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca title=\"Novus LogBox Connect LTE Datasheet Download\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/LogBox_LTE_Datasheet.pdf?v=1764849833\" style=\"color: rgb(43, 0, 255);\"\u003eNovus LogBox Connect LTE Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca title=\"Novus LogBox Connect LTE Manual Download\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/LogBox_LTE_Manual.pdf?v=1764849837\" style=\"color: rgb(43, 0, 255);\"\u003eNovus LogBox Connect LTE Manual Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cp\u003eInput Signals: 1 Digital Input, 2 Analog Inputs\u003c\/p\u003e\n\u003cp\u003eAnalog signal type: Thermocouples J, K, T, N, E, R, S, B; Pt100, 0-50mV, 0-5V, 0-10V, 0-20mA, 4-20mA\u003c\/p\u003e\n\u003cp\u003eDigital Input Functions: Count Pulses, Register Events, or Start Logger. Digital Output: 1 PNP Output (Electronic Key or Alarm)\u003c\/p\u003e\n\u003cp\u003eInternal sensors: NTC for temperature, Battery Voltage, External Source Voltage\u003c\/p\u003e\n\u003cp\u003eDisplay: 3 lines, 4½ digits. Resolution: Analog 15 bits, Pulse counter 16 bits\u003c\/p\u003e\n\u003cp\u003eMemory: 140,000 records. Recording Interval: 1sec to 12h. Variable Record: Instantaneous or average\u003c\/p\u003e\n\u003cp\u003eAcquisition Trigger: Date\/Time, Start button, Digital Input, or by software\u003c\/p\u003e\n\u003cp\u003eAlarms: 8 (two per channel), minimum and maximum. Internal Buzzer: Yes\u003c\/p\u003e\n\u003cp\u003eCommunication: Mobile (NB-IoT, Cat-M), USB. Configuration software: NXperience for Windows and NXperience Mobile app\u003c\/p\u003e\n\u003cp\u003ePower: 10-30VDC. Backup battery: 1 alkaline battery\u003c\/p\u003e\n\u003cp\u003eOperating Temperature: with source -20 to 60°C. Housing Protection: IP40. Dimensions: 120 x 100 x 40mm\u003c\/p\u003e\n\u003cp\u003eLTE Bands: 1, 2, 3, 4, 5, 8, 12, 13, 18, 19, 20, 25, 26, 27, 28, 66, 71, 85\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a Cloud broker to use this device?\u003c\/strong\u003e\u003cbr\u003eTo view and download remotely you need a Cloud broker. For local download via USB, use a laptop running NXperience software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a special SIM card?\u003c\/strong\u003e\u003cbr\u003eA standard micro SIM from any leading mobile provider works — test with a PAYG data SIM at the site first. A fixed IP SIM is not required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use the device purely on battery supply?\u003c\/strong\u003e\u003cbr\u003eIt has a rechargeable battery for limited standalone operation (up to 80 hours). The main power source is the external 10-30VDC supply, which can also come from a battery bank.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow much is a Novus Cloud subscription?\u003c\/strong\u003e\u003cbr\u003eThe STARTER package is free for one device, covering 180,000 records annually. BASIC costs £140\/year with higher limits; a CUSTOM plan suits advanced multi-device users.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow easy is it to install and set up?\u003c\/strong\u003e\u003cbr\u003eInitial configuration via USB with NXperience takes about 30 minutes. Once the SIM is active, register a Novus Cloud account and the device can be functional within 1-2 hours.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDistributed \u0026amp; Off-Grid Assets\u003c\/strong\u003e — cellular connectivity works where WiFi or wired networks aren't available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlow, Pressure \u0026amp; Level Monitoring\u003c\/strong\u003e — remote sites needing MQTT\/cloud visibility without local infrastructure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMobile \u0026amp; Vehicle-Mounted Equipment\u003c\/strong\u003e — battery backup and cellular link suit non-fixed installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Do I need a Cloud broker to use this device?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"To view and download remotely you need a Cloud broker. For local download via USB, use a laptop running NXperience software.\"}},{\"@type\":\"Question\",\"name\":\"Do I need a special SIM card?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A standard micro SIM from any leading mobile provider works — test with a PAYG data SIM at the site first. A fixed IP SIM is not required.\"}},{\"@type\":\"Question\",\"name\":\"Can I use the device purely on battery supply?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"It has a rechargeable battery for limited standalone operation (up to 80 hours). The main power source is the external 10-30VDC supply, which can also come from a battery bank.\"}},{\"@type\":\"Question\",\"name\":\"How much is a Novus Cloud subscription?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The STARTER package is free for one device, covering 180,000 records annually. BASIC costs £140\/year with higher limits; a CUSTOM plan suits advanced multi-device users.\"}},{\"@type\":\"Question\",\"name\":\"How easy is it to install and set up?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Initial configuration via USB with NXperience takes about 30 minutes. Once the SIM is active, register a Novus Cloud account and the device can be functional within 1-2 hours.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":56432912728437,"sku":"8813006500","price":297.13,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/t2-multichannel_iot_datalogger_logboxlte_image_02.webp?v=1764850827"},{"product_id":"wiska-wdb-t1-ip65-plastic-enclosure-with-clear-door-200x300x130mm","title":"Wiska WDB T1 IP65 Plastic Enclosure With Clear Door 300x200x130mm","description":"\u003ch2\u003eWiska WDB T1 — IP65 Plastic Enclosure With Clear Door\u003c\/h2\u003e\n\u003cp\u003eComplete lightweight enclosure with a component mounting plate and lockable door.\u003c\/p\u003e\n\u003cp\u003eSuitable for wall mounting. Easy to cut and drill on site. Available in sizes up to 800 x 600mm — contact us if you need a different size.\u003c\/p\u003e\n\u003cp\u003eThe transparent door gives a view of the internal components without opening it — ideal for light-duty applications like communications equipment, where it can be important to check status lights at a glance.\u003c\/p\u003e\n\u003cp\u003eWe recommend these enclosures for use with our range of signal conditioners and data loggers, as well as general termination and networking applications.\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003ctable class=\"table table-sm\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eGlow wire test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e650 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eTemp. range min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eTemp. range max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate, Thermo-resistant ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eProduct Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eExternal dimensions LxWxH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300x200x130mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWDB T1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eOrder no. UK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50107056\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003ePacking unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes this come with a mounting plate?\u003c\/strong\u003e\u003cbr\u003eYes — a complete lightweight component mounting plate is included behind the lockable door.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I view equipment status without opening the door?\u003c\/strong\u003e\u003cbr\u003eYes — the clear door lets you check status lights and displays at a glance, without breaking the enclosure's seal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this suitable for outdoor or exposed locations?\u003c\/strong\u003e\u003cbr\u003eIP65 rated with a -35°C to 65°C range, glow-wire tested to 650°C — suitable for most external wall-mounted installations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat if I need a size that isn't listed?\u003c\/strong\u003e\u003cbr\u003eThis range is available up to 800 x 600mm — contact us if you need a different size to the standard WDB T1\/T2.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding \u0026amp; data communications\u003c\/strong\u003e — housing network or comms equipment with visible status LEDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote monitoring \u0026amp; data logging\u003c\/strong\u003e — wall-mounted enclosure for temperature loggers and signal conditioners\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical \u0026amp; building services contractors\u003c\/strong\u003e — lockable, weatherproof housing for site termination points\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Does this come with a mounting plate?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — a complete lightweight component mounting plate is included behind the lockable door.\"}},{\"@type\":\"Question\",\"name\":\"Can I view equipment status without opening the door?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — the clear door lets you check status lights and displays at a glance, without breaking the enclosure's seal.\"}},{\"@type\":\"Question\",\"name\":\"Is this suitable for outdoor or exposed locations?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"IP65 rated with a -35°C to 65°C range, glow-wire tested to 650°C — suitable for most external wall-mounted installations.\"}},{\"@type\":\"Question\",\"name\":\"What if I need a size that isn't listed?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"This range is available up to 800 x 600mm — contact us if you need a different size to the standard WDB T1\/T2.\"}}]}\n\u003c\/script\u003e","brand":"Wiska","offers":[{"title":"Default Title","offer_id":57088779256181,"sku":"50107056","price":30.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/image_9798103cfbd617e9b38c37ec51c62950_large_1a2bf3bd-6a19-42ac-9fbf-6dc86d8e2148.jpg?v=1776750328"},{"product_id":"wiska-wdb-t2-ip65-plastic-enclosure-with-clear-door-250x350x150mm","title":"Wiska WDB T2 IP65 Plastic Enclosure With Clear Door 350x250x150mm","description":"\u003ch2\u003eWiska WDB T2 — IP65 Plastic Enclosure With Clear Door\u003c\/h2\u003e\n\u003cp\u003eComplete lightweight enclosure with a component mounting plate and lockable door. The mounting plate measures 190mm (width) x 295mm (height), with room for components up to 120mm deep. Included in the packaging: a triangular key and 4 wall-mount brackets.\u003c\/p\u003e\n\u003cp\u003eThe transparent door gives a view of the internal components without opening it — ideal for light-duty applications like communications equipment, where it can be important to check status lights at a glance.\u003c\/p\u003e\n\u003cp\u003eWe recommend these enclosures for use with our range of signal conditioners and data loggers, as well as general termination and networking applications.\u003c\/p\u003e\n\u003cp\u003eAvailable in sizes up to 800 x 600mm — contact us if you need a different size.\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003ctable class=\"table table-sm\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eProtection class\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eGlow wire test\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e650 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eTemp. range min\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-35 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eTemp. range max\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolycarbonate, Thermo-resistant ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eProduct Color\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRAL 7035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eExternal dimensions LxWxH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e350x250x150mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eWDB T2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003eOrder no. UK\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50107057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-nowrap\"\u003e\u003cstrong\u003ePacking unit\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat size is the mounting plate?\u003c\/strong\u003e\u003cbr\u003e190mm (width) x 295mm (height), with up to 120mm of depth clearance for components.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's the difference between this and the WDB T1?\u003c\/strong\u003e\u003cbr\u003eLarger overall footprint and more internal depth (120mm component clearance), for bigger mounting plate layouts than the T1.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's included in the box?\u003c\/strong\u003e\u003cbr\u003eThe enclosure, mounting plate, a triangular door key, and 4 wall-mount brackets.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this suitable for outdoor or exposed locations?\u003c\/strong\u003e\u003cbr\u003eIP65 rated with a -35°C to 65°C range, glow-wire tested to 650°C — suitable for most external wall-mounted installations.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding \u0026amp; data communications\u003c\/strong\u003e — housing larger network or comms equipment with visible status LEDs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote monitoring \u0026amp; data logging\u003c\/strong\u003e — wall-mounted enclosure for temperature loggers and signal conditioners\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical \u0026amp; building services contractors\u003c\/strong\u003e — lockable, weatherproof housing for larger site termination points\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What size is the mounting plate?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"190mm (width) x 295mm (height), with up to 120mm of depth clearance for components.\"}},{\"@type\":\"Question\",\"name\":\"What's the difference between this and the WDB T1?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Larger overall footprint and more internal depth (120mm component clearance), for bigger mounting plate layouts than the T1.\"}},{\"@type\":\"Question\",\"name\":\"What's included in the box?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The enclosure, mounting plate, a triangular door key, and 4 wall-mount brackets.\"}},{\"@type\":\"Question\",\"name\":\"Is this suitable for outdoor or exposed locations?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"IP65 rated with a -35°C to 65°C range, glow-wire tested to 650°C — suitable for most external wall-mounted installations.\"}}]}\n\u003c\/script\u003e","brand":"Wiska","offers":[{"title":"Default Title","offer_id":57088779911541,"sku":"50107057","price":36.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/image_9798103cfbd617e9b38c37ec51c62950_large_1a2bf3bd-6a19-42ac-9fbf-6dc86d8e2148.jpg?v=1776750328"},{"product_id":"novus-digirail-iot-sensor-gateway-ethernet-mqtt-modbus-2ai-6di-2do","title":"Novus DigiRail IoT Sensor Gateway | RS485 Master (2AI \/ 6DI \/ 2DO) Ethernet Version MQTT","description":"\u003ch2\u003e\u003cstrong\u003eDigiRail IoT Gateway With Ethernet\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThis economical module solves the problem of data collection in local or remote applications. DigiRail IoT helps assimilate sensors and RS485 devices using existing network infrastructure to provide data acquisition and logging — hardwired remote I\/O to MQTT or Modbus, passing data to OEE, DCS, or SCADA, with open MQTT broker compatibility and gateway functions for both Modbus TCP-to-RTU and Modbus RTU-to-MQTT, plus an RS485 Master mode with 8 channels\/registers.\u003c\/p\u003e\n\u003cp\u003eDirect connection of sensors and analogue signals is supported. The module contains 6 digital inputs, individually configurable to monitor state (On\/Off) or act as counters, plus two analogue inputs and two digital outputs.\u003c\/p\u003e\n\u003cp\u003eInitial configuration in Novus NXperience is an extremely quick process. With a small amount of interface wiring the module can begin gathering data in minutes. This can be passed via MQTT to Cloud services, or sent to PLC\/SCADA systems using the Modbus TCP protocol.\u003c\/p\u003e\n\u003ch3\u003eModbus TCP to RTU Pass-Through Gateway\u003c\/h3\u003e\n\u003cp\u003eThis model can be used as a transparent gateway with no mapping of registers required. It's suitable for reading\/writing registers on RTU Slaves wired to the RS485 terminals — simply communicate via Modbus TCP and the module automatically translates commands.\u003c\/p\u003e\n\u003cp\u003eGateway Mode is a simple method allowing IT equipment or PLCs with Ethernet ports to communicate with devices such as temperature controllers, instruments, and meters — removing the physical mismatch between Ethernet\/LAN cabling and RS485, and compensating for differences in protocol message structure.\u003c\/p\u003e\n\u003ch3\u003eModbus RS485 Master Mode\u003c\/h3\u003e\n\u003cp\u003eWhen configured as an RS485 Master, the IoT Gateway can receive up to 8 registers via the built-in RS485 terminals — useful for collecting data from field devices such as metering equipment equipped with RS485 terminals. The 8 registers can be received from a single device or multiple devices with different addresses. Unlike basic gateway mode, register values are held in the device's internal memory.\u003c\/p\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: rgb(43, 0, 255);\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" alt=\"\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/industrialiotgateway_digirial_iot_folheto_v1.0_en.pdf?v=1781688167\" title=\"Novus DigiRail IoT Ethernet Datasheet Download\" style=\"color: rgb(43, 0, 255);\"\u003eNovus DigiRail IoT Ethernet Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/Manual_DigiRail_IoT_EN.pdf?v=1781688170\" title=\"Novus DigiRail IoT Ethernet Manual Download\" style=\"color: rgb(43, 0, 255);\"\u003eNovus DigiRail IoT Ethernet Manual Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cp\u003eInputs: 6 digital, 2 analog. Outputs: 2 digital\u003c\/p\u003e\n\u003cp\u003eAnalog input types: 0-5V, 0-10V, 0-20mA, 4-20mA. Digital input types: NPN, PNP, dry contact\u003c\/p\u003e\n\u003cp\u003eAnalog input impedance: mA 15Ω+1.5V, V 1MΩ\u003c\/p\u003e\n\u003cp\u003eDigital input: Logic \"0\" \u0026lt;0.5V, Logic \"1\" \u0026gt;3V, max voltage 30V, input impedance 270kΩ, input current @30VDC typical 0.15mA\u003c\/p\u003e\n\u003cp\u003eMax frequency: dry contact 10Hz, PNP\/NPN 3kHz. Min pulse duration: dry contact 50ms, PNP\/NPN 150μs\u003c\/p\u003e\n\u003cp\u003eDigital outputs: 2 NPN-type, max switchable current 700mA\u003c\/p\u003e\n\u003cp\u003eAnalog inputs: 15 bits (32,000 levels)\u003c\/p\u003e\n\u003cp\u003eCommunication: USB, Ethernet 10\/100 Mb\/s (IEEE 802.3u), RS485. Software: NXperience\u003c\/p\u003e\n\u003cp\u003ePower supply: 10-30VDC. Consumption: 50mA @24V, 120mA @12V\u003c\/p\u003e\n\u003cp\u003eOperating conditions: -20 to 60°C, 5-95% RH non-condensing\u003c\/p\u003e\n\u003cp\u003eBattery: CR2032 for internal clock retention. Mounting: DIN rail or screw. Protection: IP20. Enclosure: ABS+PC\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this connect existing RS485 devices to an Ethernet network?\u003c\/strong\u003e\u003cbr\u003eYes — as a transparent Modbus TCP to RTU gateway, it lets Ethernet-equipped PLCs communicate with RS485-only field devices with no register mapping required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it collect data without a full Modbus network?\u003c\/strong\u003e\u003cbr\u003eYes — in RS485 Master mode it reads up to 8 registers directly from one or more field devices, holding the values in its own internal memory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs there a WiFi version?\u003c\/strong\u003e\u003cbr\u003eYes — see our DigiRail IoT WiFi model if you need wireless rather than wired Ethernet connectivity.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Data Collection\u003c\/strong\u003e — gathers sensor and RS485 device data over existing network infrastructure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEE \u0026amp; Machine Monitoring\u003c\/strong\u003e — passes hardwired I\/O data to OEE, DCS, or SCADA systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy Device Integration\u003c\/strong\u003e — bridges RS485-only field devices onto an Ethernet\/Modbus TCP network.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Can this connect existing RS485 devices to an Ethernet network?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — as a transparent Modbus TCP to RTU gateway, it lets Ethernet-equipped PLCs communicate with RS485-only field devices with no register mapping required.\"}},{\"@type\":\"Question\",\"name\":\"Can it collect data without a full Modbus network?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — in RS485 Master mode it reads up to 8 registers directly from one or more field devices, holding the values in its own internal memory.\"}},{\"@type\":\"Question\",\"name\":\"Is there a WiFi version?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — see our DigiRail IoT WiFi model if you need wireless rather than wired Ethernet connectivity.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":57299719258485,"sku":"8811825420","price":112.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/iomoduleforiotapplication_digirailIoT_image_v1.6_semsombra.png?v=1781687587"},{"product_id":"novus-digirail-iot-sensor-gateway-mqtt-modbus-2ai-6di-2do-wifi-version","title":"Novus DigiRail IoT Sensor Gateway | RS485 Master (2AI \/ 6DI \/ 2DO) WiFi Version MQTT","description":"\u003ch2\u003e\u003cstrong\u003eDigiRail IoT Gateway With WiFi\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThis economical module solves the problem of data collection in local or remote applications. DigiRail IoT helps assimilate sensors and RS485 devices using existing network infrastructure to provide data acquisition and logging — hardwired remote I\/O to MQTT or Modbus, passing data to OEE, DCS, or SCADA, with open MQTT broker compatibility and gateway functions for both Modbus TCP-to-RTU and Modbus RTU-to-MQTT, plus an RS485 Master mode with 8 channels\/registers.\u003c\/p\u003e\n\u003cp\u003eDirect connection of sensors and analogue signals is supported. The module contains 6 digital inputs, individually configurable to monitor state (On\/Off) or act as counters, plus two analogue inputs and two digital outputs.\u003c\/p\u003e\n\u003cp\u003eInitial configuration in Novus NXperience is an extremely quick process. With a small amount of interface wiring the module can begin gathering data in minutes. This can be passed via MQTT to Cloud services, or sent to PLC\/SCADA systems using the Modbus TCP protocol.\u003c\/p\u003e\n\u003ch3\u003eModbus TCP to RTU Pass-Through Gateway\u003c\/h3\u003e\n\u003cp\u003eThis model can be used as a transparent gateway with no mapping of registers required. It's suitable for reading\/writing registers on RTU Slaves wired to the RS485 terminals — simply communicate via Modbus TCP and the module automatically translates commands.\u003c\/p\u003e\n\u003cp\u003eGateway Mode is a simple method allowing IT equipment or PLCs with Ethernet ports to communicate with devices such as temperature controllers, instruments, and meters — removing the physical mismatch between Ethernet\/LAN cabling and RS485, and compensating for differences in protocol message structure.\u003c\/p\u003e\n\u003ch3\u003eModbus RS485 Master Mode\u003c\/h3\u003e\n\u003cp\u003eWhen configured as an RS485 Master, the IoT Gateway can receive up to 8 registers via the built-in RS485 terminals — useful for collecting data from field devices such as metering equipment equipped with RS485 terminals. The 8 registers can be received from a single device or multiple devices with different addresses. Unlike basic gateway mode, register values are held in the device's internal memory.\u003c\/p\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: rgb(43, 0, 255);\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" alt=\"\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/industrialiotgateway_digirial_iot_folheto_v1.0_en.pdf?v=1781688167\" title=\"Novus DigiRail IoT Datasheet Download\" style=\"color: rgb(43, 0, 255);\"\u003eNovus DigiRail IoT Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/Manual_DigiRail_IoT_EN.pdf?v=1781688170\" title=\"Novus DigiRail IoT Manual Download\" style=\"color: rgb(43, 0, 255);\"\u003eNovus DigiRail IoT Manual Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cp\u003eInputs: 6 digital, 2 analog. Outputs: 2 digital\u003c\/p\u003e\n\u003cp\u003eAnalog input types: 0-5V, 0-10V, 0-20mA, 4-20mA. Digital input types: NPN, PNP, dry contact\u003c\/p\u003e\n\u003cp\u003eAnalog input impedance: mA 15Ω+1.5V, V 1MΩ\u003c\/p\u003e\n\u003cp\u003eDigital input: Logic \"0\" \u0026lt;0.5V, Logic \"1\" \u0026gt;3V, max voltage 30V, input impedance 270kΩ, input current @30VDC typical 0.15mA\u003c\/p\u003e\n\u003cp\u003eMax frequency: dry contact 10Hz, PNP\/NPN 3kHz. Min pulse duration: dry contact 50ms, PNP\/NPN 150μs\u003c\/p\u003e\n\u003cp\u003eDigital outputs: 2 NPN-type, max switchable current 700mA\u003c\/p\u003e\n\u003cp\u003eAnalog inputs: 15 bits (32,000 levels)\u003c\/p\u003e\n\u003cp\u003eCommunication: USB, WiFi 802.11 b\/g\/n 2.4GHz, RS485. Software: NXperience\u003c\/p\u003e\n\u003cp\u003ePower supply: 10-30VDC. Consumption: 70mA @24V, 160mA @12V\u003c\/p\u003e\n\u003cp\u003eOperating conditions: -20 to 60°C, 5-95% RH non-condensing\u003c\/p\u003e\n\u003cp\u003eBattery: CR2032 for internal clock retention. Mounting: DIN rail or screw. Protection: IP20. Enclosure: ABS+PC\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat's the difference between this and the Ethernet model?\u003c\/strong\u003e\u003cbr\u003eOnly the network connection — this WiFi version avoids running a new Ethernet cable, useful where the module needs to be sited away from existing network points. Consumption is slightly higher on WiFi.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it collect data without a full Modbus network?\u003c\/strong\u003e\u003cbr\u003eYes — in RS485 Master mode it reads up to 8 registers directly from one or more field devices, holding the values in its own internal memory.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this connect existing RS485 devices to a WiFi network?\u003c\/strong\u003e\u003cbr\u003eYes — as a transparent Modbus TCP to RTU gateway, it lets WiFi-equipped PLCs\/SCADA systems communicate with RS485-only field devices with no register mapping required.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRetrofit Installations\u003c\/strong\u003e — WiFi connectivity avoids new cable runs to hard-to-reach machinery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOEE \u0026amp; Machine Monitoring\u003c\/strong\u003e — passes hardwired I\/O data to OEE, DCS, or SCADA systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLegacy Device Integration\u003c\/strong\u003e — bridges RS485-only field devices onto a wireless Modbus TCP network.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What's the difference between this and the Ethernet model?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Only the network connection — this WiFi version avoids running a new Ethernet cable, useful where the module needs to be sited away from existing network points. Consumption is slightly higher on WiFi.\"}},{\"@type\":\"Question\",\"name\":\"Can it collect data without a full Modbus network?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — in RS485 Master mode it reads up to 8 registers directly from one or more field devices, holding the values in its own internal memory.\"}},{\"@type\":\"Question\",\"name\":\"Can this connect existing RS485 devices to a WiFi network?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — as a transparent Modbus TCP to RTU gateway, it lets WiFi-equipped PLCs\/SCADA systems communicate with RS485-only field devices with no register mapping required.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":57299866583413,"sku":"8811825460","price":119.87,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/iomoduleforiotapplication_digirailIoT_image_v1.6_semsombra.png?v=1781687587"},{"product_id":"novus-digirail-connect-dmix-ethernet-io-module-8di-4-relay","title":"Novus DigiRail Connect DMIX | Ethernet IO Module Modbus TCP\/RTU (8DI \/ 4 Relay)","description":"\u003cp\u003eThe \u003cstrong\u003eNovus DigiRail Connect DMIX 8DI \/ 4 Relay\u003c\/strong\u003e (8811612440) adds 8 digital inputs and 4 relay outputs to almost any PLC, SCADA or data logging system, over Ethernet (Modbus TCP) or RS485 (Modbus RTU). The relays give volt-free contacts for switching contactor coils, alarms, valves and other AC or DC loads up to 250Vac, while the inputs accept PNP, NPN or dry contact signals and can be configured as pulse counters.\u003c\/p\u003e\n\u003cp\u003eEvery DigiRail Connect model has Ethernet, RS485 and Micro USB on board. It works as a Modbus RTU slave on an existing RS485 network or as a Modbus TCP server on Ethernet, and can act as a transparent Modbus TCP to RTU gateway, so an Ethernet PLC or SCADA system can read RS485 instruments wired to its terminals with no register mapping. Configuration and I\/O testing use free Novus NXperience software over USB.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLead time:\u003c\/strong\u003e made to order by Novus, typically 1–2 weeks to dispatch.\u003c\/p\u003e\n\u003ch3\u003eDigiRail Connect Range\u003c\/h3\u003e\n\u003cp\u003eAll four DigiRail Connect models share the same Ethernet\/RS485 hardware and software. Choose by the I\/O mix you need:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-connect-dmix-ethernet-io-module-8di-8do\" style=\"color: #0000ff; font-weight:bold;\"\u003eDMIX 8DI \/ 8DO (8811612420)\u003c\/a\u003e\u003c\/strong\u003e — 8 digital inputs, 8 PNP transistor outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDMIX 8DI \/ 4 Relay (8811612440)\u003c\/strong\u003e — this model: 8 digital inputs, 4 relay outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-connect-ramix-ethernet-io-module-2ai-2ao-4di-3do\" style=\"color: #0000ff; font-weight:bold;\"\u003eRAMIX 2AI \/ 2AO \/ 4DI \/ 3DO (8811611420)\u003c\/a\u003e\u003c\/strong\u003e — 2 universal analogue inputs, 2 analogue outputs, 4 digital inputs, 3 PNP outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-connect-ramix-ethernet-io-module-2ai-2ao-4di-2-relay\" style=\"color: #0000ff; font-weight:bold;\"\u003eRAMIX 2AI \/ 2AO \/ 4DI \/ 2 Relay (8811611440)\u003c\/a\u003e\u003c\/strong\u003e — as above with 2 relay outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOnly need analogue inputs on RS485? The lower-cost \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-2a-analogue-input-module-modbus-rs485\" style=\"color: #0000ff; font-weight:bold;\"\u003eNovus DigiRail-2A\u003c\/a\u003e\u003c\/strong\u003e converts two thermocouple, Pt100, mV, V or mA signals to Modbus RTU.\u003c\/p\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: #0000ff; font-weight:bold;\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" alt=\"PDF\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/ethernet_io_module_digirailconnect_20191010_fl_en.pdf?v=1707947248\" title=\"Novus DigiRail Connect Datasheet Download\" style=\"color: #0000ff; font-weight:bold;\"\u003eNovus DigiRail Connect Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" alt=\"PDF\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/manual_digirail_connect_v10x_h_en.pdf?v=1707946946\" title=\"Novus DigiRail Connect Manual Download\" style=\"color: #0000ff; font-weight:bold;\"\u003eNovus DigiRail Connect Manual Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cp\u003eOrder code: 8811612440 (DigiRail Connect DMIX 8DI \/ 4RL ETH)\u003c\/p\u003e\n\u003cp\u003eDigital inputs: 8, PNP, NPN or dry contact, configurable counter function\u003c\/p\u003e\n\u003cp\u003eRelay outputs: 4, switching voltage up to 250Vac, resistive loads (see manual for per-channel current rating)\u003c\/p\u003e\n\u003cp\u003eCommunication: Ethernet 10\/100 Mb\/s (IEEE 802.3u), RS485, Micro USB\u003c\/p\u003e\n\u003cp\u003eProtocols: Modbus TCP server, Modbus RTU slave, transparent Modbus TCP to RTU gateway\u003c\/p\u003e\n\u003cp\u003eConfiguration software: Novus NXperience (free, via USB)\u003c\/p\u003e\n\u003cp\u003ePower supply: 10-36 Vdc, 5W max (20mA typical)\u003c\/p\u003e\n\u003cp\u003eOperating conditions: -20 to 60°C, 5-95% RH non-condensing\u003c\/p\u003e\n\u003cp\u003eEnclosure: ABS+PC, 35mm DIN rail mounting\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eShould I choose this relay model or the DMIX 8DI \/ 8DO?\u003c\/strong\u003e\u003cbr\u003eChoose this model when you need volt-free contacts or want to switch AC loads directly. The 8DO model has more outputs and PNP transistor switching, which suits PLC-level DC signals and fast pulsing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the relays switch a motor or heater directly?\u003c\/strong\u003e\u003cbr\u003eThe relays are rated for resistive loads at up to 250Vac. For motors, heaters or large inductive loads, use a relay to drive a contactor coil such as the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn0910nue-contactor-9a-4kw-230v-coil-1-n-o-aux\" style=\"color: #0000ff; font-weight:bold;\"\u003eEMAS HN0910NUE\u003c\/a\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan the digital inputs count pulses?\u003c\/strong\u003e\u003cbr\u003eYes. Each input can be configured as a counter in NXperience, which suits flow meter pulses, production counts and run-hour monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens if communication is lost?\u003c\/strong\u003e\u003cbr\u003eA configurable watchdog drives the relays to a defined safe state if the Modbus master stops communicating.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump \u0026amp; fan control\u003c\/strong\u003e — switches contactor coils from SCADA or a PLC over Ethernet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm \u0026amp; status signalling\u003c\/strong\u003e — drives beacons and sounders while reading alarm and run contacts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote plant room I\/O\u003c\/strong\u003e — brings distant status and control points onto an existing Modbus network.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Should I choose this relay model or the DMIX 8DI \/ 8DO?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Choose this model when you need volt-free contacts or want to switch AC loads directly. The 8DO model has more outputs and PNP transistor switching, which suits PLC-level DC signals and fast pulsing.\"}},{\"@type\":\"Question\",\"name\":\"Can the relays switch a motor or heater directly?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The relays are rated for resistive loads at up to 250Vac. For motors, heaters or large inductive loads, use a relay to drive a contactor coil such as the EMAS HN0910NUE.\"}},{\"@type\":\"Question\",\"name\":\"Can the digital inputs count pulses?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Each input can be configured as a counter in NXperience, which suits flow meter pulses, production counts and run-hour monitoring.\"}},{\"@type\":\"Question\",\"name\":\"What happens if communication is lost?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"A configurable watchdog drives the relays to a defined safe state if the Modbus master stops communicating.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":57641769173365,"sku":"8811612440","price":196.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/t2-modulo_io_ethernet_digirail_connect_dmix_01.jpg?v=1679813268"},{"product_id":"novus-digirail-connect-ramix-ethernet-io-module-2ai-2ao-4di-3do","title":"Novus DigiRail Connect RAMIX | Ethernet IO Module Modbus TCP\/RTU (2AI \/ 2AO \/ 4DI \/ 3DO)","description":"\u003cp\u003eThe \u003cstrong\u003eNovus DigiRail Connect RAMIX 2AI \/ 2AO \/ 4DI \/ 3DO\u003c\/strong\u003e (8811611420) combines 2 isolated universal analogue inputs, 2 isolated analogue outputs, 4 digital inputs and 3 PNP digital outputs in one DIN rail module. The analogue inputs read thermocouples, Pt100\/Pt1000, NTC and mV, V or mA signals directly at 16-bit resolution, so sensors wire straight in without separate transmitters. The outputs provide 0-20mA, 4-20mA or 0-10V for drives, valves and displays.\u003c\/p\u003e\n\u003cp\u003eEvery DigiRail Connect model has Ethernet, RS485 and Micro USB on board. It works as a Modbus RTU slave on an existing RS485 network or as a Modbus TCP server on Ethernet, and can act as a transparent Modbus TCP to RTU gateway, so an Ethernet PLC or SCADA system can read RS485 instruments wired to its terminals with no register mapping. Configuration and I\/O testing use free Novus NXperience software over USB.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLead time:\u003c\/strong\u003e made to order by Novus, typically 1–2 weeks to dispatch.\u003c\/p\u003e\n\u003ch3\u003eDigiRail Connect Range\u003c\/h3\u003e\n\u003cp\u003eAll four DigiRail Connect models share the same Ethernet\/RS485 hardware and software. Choose by the I\/O mix you need:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-connect-dmix-ethernet-io-module-8di-8do\" style=\"color: #0000ff; font-weight:bold;\"\u003eDMIX 8DI \/ 8DO (8811612420)\u003c\/a\u003e\u003c\/strong\u003e — 8 digital inputs, 8 PNP transistor outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-connect-dmix-ethernet-io-module-8di-4-relay\" style=\"color: #0000ff; font-weight:bold;\"\u003eDMIX 8DI \/ 4 Relay (8811612440)\u003c\/a\u003e\u003c\/strong\u003e — 8 digital inputs, 4 relay outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRAMIX 2AI \/ 2AO \/ 4DI \/ 3DO (8811611420)\u003c\/strong\u003e — this model: 2 universal analogue inputs, 2 analogue outputs, 4 digital inputs, 3 PNP outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-connect-ramix-ethernet-io-module-2ai-2ao-4di-2-relay\" style=\"color: #0000ff; font-weight:bold;\"\u003eRAMIX 2AI \/ 2AO \/ 4DI \/ 2 Relay (8811611440)\u003c\/a\u003e\u003c\/strong\u003e — as this model but with 2 relay outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOnly need analogue inputs on RS485? The lower-cost \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-2a-analogue-input-module-modbus-rs485\" style=\"color: #0000ff; font-weight:bold;\"\u003eNovus DigiRail-2A\u003c\/a\u003e\u003c\/strong\u003e converts two thermocouple, Pt100, mV, V or mA signals to Modbus RTU.\u003c\/p\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: #0000ff; font-weight:bold;\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" alt=\"PDF\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/ethernet_io_module_digirailconnect_20191010_fl_en.pdf?v=1707947248\" title=\"Novus DigiRail Connect Datasheet Download\" style=\"color: #0000ff; font-weight:bold;\"\u003eNovus DigiRail Connect Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" alt=\"PDF\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/manual_digirail_connect_v10x_h_en.pdf?v=1707946946\" title=\"Novus DigiRail Connect Manual Download\" style=\"color: #0000ff; font-weight:bold;\"\u003eNovus DigiRail Connect Manual Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cp\u003eOrder code: 8811611420 (DigiRail Connect RAMIX 2AI \/ 2AO \/ 4DI \/ 3DO ETH)\u003c\/p\u003e\n\u003cp\u003eAnalogue inputs: 2, isolated, universal: thermocouple J, K, T, N, E, R, S, B; Pt100, Pt1000, NTC; 0-60mV, 0-5V, 0-10V, 0-20mA, 4-20mA. 16-bit resolution\u003c\/p\u003e\n\u003cp\u003eAnalogue outputs: 2, isolated, 0-20mA, 4-20mA or 0-10V. 12-bit resolution\u003c\/p\u003e\n\u003cp\u003eDigital inputs: 4, PNP, NPN or dry contact, configurable counter function\u003c\/p\u003e\n\u003cp\u003eDigital outputs: 3, PNP transistor, 200mA max load per output, 6-30 Vdc switching\u003c\/p\u003e\n\u003cp\u003eCommunication: Ethernet 10\/100 Mb\/s (IEEE 802.3u), RS485, Micro USB\u003c\/p\u003e\n\u003cp\u003eProtocols: Modbus TCP server, Modbus RTU slave, transparent Modbus TCP to RTU gateway\u003c\/p\u003e\n\u003cp\u003eConfiguration software: Novus NXperience (free, via USB)\u003c\/p\u003e\n\u003cp\u003ePower supply: 10-36 Vdc, 5W max (20mA typical)\u003c\/p\u003e\n\u003cp\u003eOperating conditions: -20 to 60°C, 5-95% RH non-condensing\u003c\/p\u003e\n\u003cp\u003eEnclosure: ABS+PC, 35mm DIN rail mounting\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat can the analogue inputs read directly?\u003c\/strong\u003e\u003cbr\u003eThermocouples (J, K, T, N, E, R, S, B), Pt100, Pt1000 and NTC sensors, plus 0-60mV, 0-5V, 0-10V, 0-20mA and 4-20mA signals. Each channel is configured independently in NXperience.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need RAMIX or DMIX?\u003c\/strong\u003e\u003cbr\u003eChoose RAMIX when you need analogue measurement or an analogue output. DMIX models suit applications where every signal is on\/off and you need more discrete channels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I choose this 3DO model or the 2 Relay RAMIX?\u003c\/strong\u003e\u003cbr\u003eThis model has 3 PNP transistor outputs (up to 200mA) for PLC-level DC signals and pulsing. The 2 Relay version gives volt-free contacts for switching AC loads.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it provide a speed reference to an inverter?\u003c\/strong\u003e\u003cbr\u003eYes. The 0-10V or 4-20mA analogue outputs can set inverter speed, valve position or a remote display, driven from SCADA or a PLC over Modbus.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess monitoring\u003c\/strong\u003e — brings temperatures, pressures and flows into SCADA without separate transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote analogue control\u003c\/strong\u003e — sends speed references to inverter drives and positions proportional valves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnergy \u0026amp; utilities\u003c\/strong\u003e — data acquisition in pump stations and plant rooms over Ethernet or RS485.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What can the analogue inputs read directly?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Thermocouples (J, K, T, N, E, R, S, B), Pt100, Pt1000 and NTC sensors, plus 0-60mV, 0-5V, 0-10V, 0-20mA and 4-20mA signals. Each channel is configured independently in NXperience.\"}},{\"@type\":\"Question\",\"name\":\"Do I need RAMIX or DMIX?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Choose RAMIX when you need analogue measurement or an analogue output. DMIX models suit applications where every signal is on\/off and you need more discrete channels.\"}},{\"@type\":\"Question\",\"name\":\"Should I choose this 3DO model or the 2 Relay RAMIX?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"This model has 3 PNP transistor outputs (up to 200mA) for PLC-level DC signals and pulsing. The 2 Relay version gives volt-free contacts for switching AC loads.\"}},{\"@type\":\"Question\",\"name\":\"Can it provide a speed reference to an inverter?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. The 0-10V or 4-20mA analogue outputs can set inverter speed, valve position or a remote display, driven from SCADA or a PLC over Modbus.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":57641769337205,"sku":"8811611420","price":230.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/t2-modulo_io_ethernet_digirail_connect_ramix_02.jpg?v=1679813268"},{"product_id":"novus-digirail-connect-ramix-ethernet-io-module-2ai-2ao-4di-2-relay","title":"Novus DigiRail Connect RAMIX | Ethernet IO Module Modbus TCP\/RTU (2AI \/ 2AO \/ 4DI \/ 2 Relay)","description":"\u003cp\u003eThe \u003cstrong\u003eNovus DigiRail Connect RAMIX 2AI \/ 2AO \/ 4DI \/ 2 Relay\u003c\/strong\u003e (8811611440) combines 2 isolated universal analogue inputs, 2 isolated analogue outputs, 4 digital inputs and 2 relay outputs in one DIN rail module. The analogue inputs read thermocouples, Pt100\/Pt1000, NTC and mV, V or mA signals directly at 16-bit resolution, the analogue outputs provide 0-20mA, 4-20mA or 0-10V, and the relays give volt-free contacts for alarms, contactor coils and valves up to 250Vac.\u003c\/p\u003e\n\u003cp\u003eEvery DigiRail Connect model has Ethernet, RS485 and Micro USB on board. It works as a Modbus RTU slave on an existing RS485 network or as a Modbus TCP server on Ethernet, and can act as a transparent Modbus TCP to RTU gateway, so an Ethernet PLC or SCADA system can read RS485 instruments wired to its terminals with no register mapping. Configuration and I\/O testing use free Novus NXperience software over USB.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLead time:\u003c\/strong\u003e made to order by Novus, typically 1–2 weeks to dispatch.\u003c\/p\u003e\n\u003ch3\u003eDigiRail Connect Range\u003c\/h3\u003e\n\u003cp\u003eAll four DigiRail Connect models share the same Ethernet\/RS485 hardware and software. Choose by the I\/O mix you need:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-connect-dmix-ethernet-io-module-8di-8do\" style=\"color: #0000ff; font-weight:bold;\"\u003eDMIX 8DI \/ 8DO (8811612420)\u003c\/a\u003e\u003c\/strong\u003e — 8 digital inputs, 8 PNP transistor outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-connect-dmix-ethernet-io-module-8di-4-relay\" style=\"color: #0000ff; font-weight:bold;\"\u003eDMIX 8DI \/ 4 Relay (8811612440)\u003c\/a\u003e\u003c\/strong\u003e — 8 digital inputs, 4 relay outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-connect-ramix-ethernet-io-module-2ai-2ao-4di-3do\" style=\"color: #0000ff; font-weight:bold;\"\u003eRAMIX 2AI \/ 2AO \/ 4DI \/ 3DO (8811611420)\u003c\/a\u003e\u003c\/strong\u003e — as this model but with 3 PNP transistor outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRAMIX 2AI \/ 2AO \/ 4DI \/ 2 Relay (8811611440)\u003c\/strong\u003e — this model: 2 universal analogue inputs, 2 analogue outputs, 4 digital inputs, 2 relay outputs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOnly need analogue inputs on RS485? The lower-cost \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-digirail-2a-analogue-input-module-modbus-rs485\" style=\"color: #0000ff; font-weight:bold;\"\u003eNovus DigiRail-2A\u003c\/a\u003e\u003c\/strong\u003e converts two thermocouple, Pt100, mV, V or mA signals to Modbus RTU.\u003c\/p\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: #0000ff; font-weight:bold;\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" alt=\"PDF\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/ethernet_io_module_digirailconnect_20191010_fl_en.pdf?v=1707947248\" title=\"Novus DigiRail Connect Datasheet Download\" style=\"color: #0000ff; font-weight:bold;\"\u003eNovus DigiRail Connect Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" alt=\"PDF\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/manual_digirail_connect_v10x_h_en.pdf?v=1707946946\" title=\"Novus DigiRail Connect Manual Download\" style=\"color: #0000ff; font-weight:bold;\"\u003eNovus DigiRail Connect Manual Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cp\u003eOrder code: 8811611440 (DigiRail Connect RAMIX 2AI \/ 2AO \/ 4DI \/ 2RL ETH)\u003c\/p\u003e\n\u003cp\u003eAnalogue inputs: 2, isolated, universal: thermocouple J, K, T, N, E, R, S, B; Pt100, Pt1000, NTC; 0-60mV, 0-5V, 0-10V, 0-20mA, 4-20mA. 16-bit resolution\u003c\/p\u003e\n\u003cp\u003eAnalogue outputs: 2, isolated, 0-20mA, 4-20mA or 0-10V. 12-bit resolution\u003c\/p\u003e\n\u003cp\u003eDigital inputs: 4, PNP, NPN or dry contact, configurable counter function\u003c\/p\u003e\n\u003cp\u003eRelay outputs: 2, switching voltage up to 250Vac, resistive loads (see manual for per-channel current rating)\u003c\/p\u003e\n\u003cp\u003eCommunication: Ethernet 10\/100 Mb\/s (IEEE 802.3u), RS485, Micro USB\u003c\/p\u003e\n\u003cp\u003eProtocols: Modbus TCP server, Modbus RTU slave, transparent Modbus TCP to RTU gateway\u003c\/p\u003e\n\u003cp\u003eConfiguration software: Novus NXperience (free, via USB)\u003c\/p\u003e\n\u003cp\u003ePower supply: 10-36 Vdc, 5W max (20mA typical)\u003c\/p\u003e\n\u003cp\u003eOperating conditions: -20 to 60°C, 5-95% RH non-condensing\u003c\/p\u003e\n\u003cp\u003eEnclosure: ABS+PC, 35mm DIN rail mounting\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhat can the analogue inputs read directly?\u003c\/strong\u003e\u003cbr\u003eThermocouples (J, K, T, N, E, R, S, B), Pt100, Pt1000 and NTC sensors, plus 0-60mV, 0-5V, 0-10V, 0-20mA and 4-20mA signals. Each channel is configured independently in NXperience.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShould I choose this relay model or the RAMIX 3DO?\u003c\/strong\u003e\u003cbr\u003eChoose this model when you need volt-free contacts or to switch AC loads such as alarms and contactor coils. The 3DO version has PNP transistor outputs for PLC-level DC signals and pulsing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it control a heater or motor?\u003c\/strong\u003e\u003cbr\u003eThe relays are rated for resistive loads at up to 250Vac. For heaters, motors or other large loads, use a relay to drive a contactor coil such as the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/emas-hn0910nue-contactor-9a-4kw-230v-coil-1-n-o-aux\" style=\"color: #0000ff; font-weight:bold;\"\u003eEMAS HN0910NUE\u003c\/a\u003e\u003c\/strong\u003e, with control logic in your PLC or SCADA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan it bridge RS485 devices onto Ethernet?\u003c\/strong\u003e\u003cbr\u003eYes. In gateway mode it passes Modbus TCP requests to RTU slaves wired to its RS485 terminals with no register mapping, so an Ethernet PLC can read existing RS485 controllers and meters.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature monitoring \u0026amp; alarms\u003c\/strong\u003e — reads thermocouples or Pt100 sensors and trips relay alarms from SCADA set points.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote analogue control\u003c\/strong\u003e — sends 0-10V or 4-20mA references to drives and valves while switching run signals.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilding management\u003c\/strong\u003e — combines sensor inputs, analogue outputs and plant switching in one BMS module.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"What can the analogue inputs read directly?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Thermocouples (J, K, T, N, E, R, S, B), Pt100, Pt1000 and NTC sensors, plus 0-60mV, 0-5V, 0-10V, 0-20mA and 4-20mA signals. Each channel is configured independently in NXperience.\"}},{\"@type\":\"Question\",\"name\":\"Should I choose this relay model or the RAMIX 3DO?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Choose this model when you need volt-free contacts or to switch AC loads such as alarms and contactor coils. The 3DO version has PNP transistor outputs for PLC-level DC signals and pulsing.\"}},{\"@type\":\"Question\",\"name\":\"Can it control a heater or motor?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"The relays are rated for resistive loads at up to 250Vac. For heaters, motors or other large loads, use a relay to drive a contactor coil such as the EMAS HN0910NUE, with control logic in your PLC or SCADA.\"}},{\"@type\":\"Question\",\"name\":\"Can it bridge RS485 devices onto Ethernet?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. In gateway mode it passes Modbus TCP requests to RTU slaves wired to its RS485 terminals with no register mapping, so an Ethernet PLC can read existing RS485 controllers and meters.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":57641769501045,"sku":"8811611440","price":230.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/t2-modulo_io_ethernet_digirail_connect_ramix_02.jpg?v=1679813268"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/collections\/t2-superview_telas_site.jpg?v=1681752184","url":"https:\/\/www.production-automation.co.uk\/collections\/scada-software.oembed?page=2","provider":"Production Automation","version":"1.0","type":"link"}