{"title":"Process Indicators","description":"\u003cp\u003eDigital process indicators from Novus for displaying 4-20mA, 0-10V and temperature signals on a panel or at the sensor. See also \u003ca href=\"\/collections\/process-indication-signal-conversion\"\u003eSignal Conversion \u0026amp; Process Indication\u003c\/a\u003e.\u003c\/p\u003e","products":[{"product_id":"n1540-usb-universal-indicator-2-relays-4-20-ma","title":"Novus N1540-RT USB Universal Indicator\/Control, 2 relays + 4-20 mA (100-240V)","description":"\u003cp\u003eThe \u003cstrong\u003eN1540\u003c\/strong\u003e is a powerful Universal Indicator used for local indication of a process variable, offering retransmission via 4-20mA signal back to a control device such as a PLC. Large digits give clear visibility, and a basic requirement such as displaying temperature, pressure or speed can be set up quickly, with further options to set alarm limits linked to the two output relays. It reads process sensors and signals from a universal input, doubling as display, scaling and retransmission all in one, and includes an auxiliary 24VDC power supply for direct connection of 2-wire 4-20mA sensors\/transducers.\u003c\/p\u003e\n\u003cp\u003eIt can also function as a standalone controller — for example, by using the switching outputs it's possible to set up the indicator as a level controller. All configuration is carried out using free Novus software and the onboard USB port.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eN1540\u003c\/strong\u003e universal process indicator works at a fast sampling rate, ensuring high-performance indication and response to fast-varying processes. With 5 digits for high-resolution variables and a 17mm-high display, \u003cstrong\u003eN1540\u003c\/strong\u003e provides a clear view, making it easier for operators to read and diagnose from a distance. Both electronic robustness and anti-flame material enclosure comply with the main world-class approvals for industry devices.\u003c\/p\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: rgb(43, 0, 255);\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca title=\"Novus N1540-RT Datasheet Download\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/20200813_universal_process_indicator_n1540_commercial_flyer_en.pdf?v=1652344003\" style=\"color: rgb(43, 0, 255);\"\u003eNovus N1540-RT Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca title=\"Novus N1540-RT Manual Download\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/manual_n1540_v21x_e_en.pdf?v=1652343932\" style=\"color: rgb(43, 0, 255);\"\u003eNovus N1540-RT Manual Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003ch4\u003eInput Signal\/Sensor Types\u003c\/h4\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/N1540_Inputs_480x480.jpg?v=1623015193\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eDisplay: LED 7-segment, 5-digit, 17 mm high\u003c\/p\u003e\n\u003cp\u003eInput Type: Thermocouples J, K, T, N, R, S, B, E, Pt100, 0-20 mA, 4-20 mA, 0-50 mV, 0-5 Vdc, 0-10 Vdc\u003c\/p\u003e\n\u003cp\u003eAccuracy: Thermocouples J, K, T: 0.2% of span ±1°C; N, R, S, B: 0.2% of span ±3°C; Pt100, 0-20mA, 4-20mA, 0-5Vdc, 0-10Vdc: 0.2% of span\u003c\/p\u003e\n\u003cp\u003eSampling Rate: Up to 55 per second. Input resolution: 15 bits\u003c\/p\u003e\n\u003cp\u003eAnalog Output: 0-20 mA or 4-20 mA (optional), electrically isolated. Output Resolution: 12 bits\u003c\/p\u003e\n\u003cp\u003eAlarm: Two alarms. Alarm Types: minimum, maximum, minimum differential, maximum differential, differential out of range, sensor open\u003c\/p\u003e\n\u003cp\u003eAuxiliary Power Supply: 24 Vdc. Optional: Analog output (4-20mA or 0-20mA), RS485. Communication: RS-485 Modbus RTU optional\u003c\/p\u003e\n\u003cp\u003eSafety: Password protected configuration. Configuration Interface: USB type Mini B (powered)\u003c\/p\u003e\n\u003cp\u003ePower Supply: 100 to 240 Vac\/dc (±10%) or 12 to 24 Vdc \/ 24 Vac (-10%\/+20%). Maximum Consumption: 6 VA\u003c\/p\u003e\n\u003cp\u003eDimensions: 96 x 48 x 34 mm (1\/8 DIN). Front Panel: IP65; Enclosure: IP30. Operating Conditions: 0 to 50°C, 0 to 80% RH up to 30°C. Approvals: CE, UL and cUL\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this work as a standalone controller, not just a display?\u003c\/strong\u003e\u003cbr\u003eYes — the two switching outputs can be configured with alarm limits, so the indicator can function as a standalone level or process controller as well as a display.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I retransmit the reading to a PLC?\u003c\/strong\u003e\u003cbr\u003eYes — the optional isolated 4-20mA analogue output retransmits the process value to a PLC or other control device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs there a 24V version?\u003c\/strong\u003e\u003cbr\u003eYes, see the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-n1540-rt-24v-usb-universal-indicator-control-2-relays-4-20-ma-12-24v\" style=\"color: rgb(43, 0, 255);\"\u003eN1540-RT-24V\u003c\/a\u003e\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Instrumentation\u003c\/strong\u003e — local display of temperature, pressure, or speed with retransmission to a PLC.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conversion \u0026amp; Interfacing\u003c\/strong\u003e — universal input accepts most industrial sensor\/signal types directly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel Control\u003c\/strong\u003e — switching outputs can be configured to run the indicator as a standalone level controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Can this work as a standalone controller, not just a display?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — the two switching outputs can be configured with alarm limits, so the indicator can function as a standalone level or process controller as well as a display.\"}},{\"@type\":\"Question\",\"name\":\"Can I retransmit the reading to a PLC?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — the optional isolated 4-20mA analogue output retransmits the process value to a PLC or other control device.\"}},{\"@type\":\"Question\",\"name\":\"Is there a 24V version?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes, see the N1540-RT-24V.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":40340621197482,"sku":"8154000220","price":92.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/t2-indicator_universal_n1540_01_icon_4-20_en_fr.jpg?v=1622790387"},{"product_id":"novus-n1540-rt-24v-usb-universal-indicator-control-2-relays-4-20-ma-12-24v","title":"Novus N1540-RT-24V USB Universal Indicator\/Control, 2 relays + 4-20 mA (12-24V)","description":"\u003cp\u003eThe Novus N1540-RT-24V is a 12-24V universal panel indicator that displays a 4-20mA, 0-10V, thermocouple or PT100 signal, with 2 alarm relays and a 4-20mA retransmission output, configured over USB.\u003c\/p\u003e\n\u003cp\u003eThe 12-24V supply model of the \u003cstrong\u003eN1540\u003c\/strong\u003e is a powerful Universal Indicator used for local indication of a process variable, offering retransmission via 4-20mA signal back to a control device such as a PLC. Large digits give clear visibility, and a basic requirement such as displaying temperature, pressure or speed can be set up quickly, with further options to set alarm limits linked to the two output relays. It reads process sensors and signals from a universal input, doubling as display, scaling and retransmission all in one, and includes an auxiliary 24VDC power supply for direct connection of 2-wire 4-20mA sensors\/transducers.\u003c\/p\u003e\n\u003cp\u003eIt can also function as a standalone controller — for example, by using the switching outputs it's possible to set up the indicator as a level controller. All configuration is carried out using free Novus software and the onboard USB port.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eN1540\u003c\/strong\u003e universal process indicator works at a fast sampling rate, ensuring high-performance indication and response to fast-varying processes. With 5 digits for high-resolution variables and a 17mm-high display, \u003cstrong\u003eN1540\u003c\/strong\u003e provides a clear view, making it easier for operators to read and diagnose from a distance. Both electronic robustness and anti-flame material enclosure comply with the main world-class approvals for industry devices.\u003c\/p\u003e\n\u003cp\u003e✅ \u003cstrong\u003e\u003ca href=\"\/pages\/warranty\" style=\"color: rgb(43, 0, 255);\"\u003e3 Year Manufacturer Warranty\u003c\/a\u003e\u003c\/strong\u003e — backed by our UK-based technical support\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" alt=\"\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/20200813_universal_process_indicator_n1540_commercial_flyer_en.pdf?v=1652344003\" title=\"Novus N1540-RT Datasheet Download\" style=\"color: rgb(43, 0, 255);\"\u003eNovus N1540-RT Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/manual_n1540_v21x_e_en.pdf?v=1652343932\" title=\"Novus N1540-RT Manual Download\" style=\"color: rgb(43, 0, 255);\"\u003eNovus N1540-RT Manual Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003ch4\u003eInput Signal\/Sensor Types\u003c\/h4\u003e\n\u003cp\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/N1540_Inputs_480x480.jpg?v=1623015193\"\u003e\u003c\/p\u003e\n\u003cp\u003eDisplay: LED 7-segment, 5-digit, 17 mm high\u003c\/p\u003e\n\u003cp\u003eInput Type: Thermocouples J, K, T, N, R, S, B, E, Pt100, 0-20 mA, 4-20 mA, 0-50 mV, 0-5 Vdc, 0-10 Vdc\u003c\/p\u003e\n\u003cp\u003eAccuracy: Thermocouples J, K, T: 0.2% of span ±1°C; N, R, S, B: 0.2% of span ±3°C; Pt100, 0-20mA, 4-20mA, 0-5Vdc, 0-10Vdc: 0.2% of span\u003c\/p\u003e\n\u003cp\u003eSampling Rate: Up to 55 per second. Input resolution: 15 bits\u003c\/p\u003e\n\u003cp\u003eAnalog Output: 0-20 mA or 4-20 mA (optional), electrically isolated. Output Resolution: 12 bits\u003c\/p\u003e\n\u003cp\u003eAlarm: Two alarms. Alarm Types: minimum, maximum, minimum differential, maximum differential, differential out of range, sensor open\u003c\/p\u003e\n\u003cp\u003eAuxiliary Power Supply: 24 Vdc. Optional: Analog output (4-20mA or 0-20mA), RS485. Communication: RS-485 Modbus RTU optional\u003c\/p\u003e\n\u003cp\u003eSafety: Password protected configuration. Configuration Interface: USB type Mini B (powered)\u003c\/p\u003e\n\u003cp\u003ePower Supply: 100 to 240 Vac\/dc (±10%) or 12 to 24 Vdc \/ 24 Vac (-10%\/+20%). Maximum Consumption: 6 VA\u003c\/p\u003e\n\u003cp\u003eDimensions: 96 x 48 x 34 mm (1\/8 DIN). Front Panel: IP65; Enclosure: IP30. Operating Conditions: 0 to 50°C, 0 to 80% RH up to 30°C. Approvals: CE, UL and cUL\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use it to display a 4-20mA pressure or level transmitter?\u003c\/strong\u003e\u003cbr\u003eYes. Scale the 4-20mA input to engineering units (for example bar or metres) and set the two relays as high and low alarms. The retransmission output can pass the signal on to a PLC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy choose the 24V version over the mains model?\u003c\/strong\u003e\u003cbr\u003eFor control panels already running 12-24V rails, off-grid installations, or mobile\/vehicle-mounted equipment where mains power isn't available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this work as a standalone controller, not just a display?\u003c\/strong\u003e\u003cbr\u003eYes — the two switching outputs can be configured with alarm limits, so the indicator can function as a standalone level or process controller as well as a display.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I retransmit the reading to a PLC?\u003c\/strong\u003e\u003cbr\u003eYes — the optional isolated 4-20mA analogue output retransmits the process value to a PLC or other control device.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-Grid \u0026amp; Mobile Process Instrumentation\u003c\/strong\u003e — 12-24V supply for remote or vehicle-mounted equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Conversion \u0026amp; Interfacing\u003c\/strong\u003e — universal input accepts most industrial sensor\/signal types directly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLevel Control\u003c\/strong\u003e — switching outputs can be configured to run the indicator as a standalone level controller.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Can I use it to display a 4-20mA pressure or level transmitter?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes. Scale the 4-20mA input to engineering units (for example bar or metres) and set the two relays as high and low alarms. The retransmission output can pass the signal on to a PLC.\"}},{\"@type\":\"Question\",\"name\":\"Why choose the 24V version over the mains model?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"For control panels already running 12-24V rails, off-grid installations, or mobile\/vehicle-mounted equipment where mains power isn't available.\"}},{\"@type\":\"Question\",\"name\":\"Can this work as a standalone controller, not just a display?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — the two switching outputs can be configured with alarm limits, so the indicator can function as a standalone level or process controller as well as a display.\"}},{\"@type\":\"Question\",\"name\":\"Can I retransmit the reading to a PLC?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — the optional isolated 4-20mA analogue output retransmits the process value to a PLC or other control device.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":42937880674474,"sku":"8154000230","price":101.08,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/products\/t2-indicator_universal_n1540_01_icon_4-20_en_fr_6512df53-1939-42b6-bc8a-33938d9070e7.jpg?v=1652344184"},{"product_id":"novus-loopview-digital-display-4-20ma-din-43650-transducer-sensor","title":"Novus LoopView Digital Display 4-20mA DIN 43650 Transducer Sensor","description":"\u003cp\u003e\u003cstrong\u003eLoopView\u003c\/strong\u003e is a fast upgrade for basic transducers, giving a local readout of process value with built-in scaling and alarms — ultra simple to install, and works with the NP640 and similar devices. It's a two-wire 4-20 mA loop indicator that can display measurements like pressure, differential pressure, flow, pH, temperature, acceleration and more, with a valve-type connector to standard EN 175301-803 (old DIN 43650 form A), available male and female.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLoopView\u003c\/strong\u003e is powered by the current loop itself, so it can be inserted into sensors already installed in industrial facilities using the same connector type. It has a 4-digit display and 2 keys, allowing quick and easy adjustment of indication value and range, decimal point position, digital signal filtering, and user calibration.\u003c\/p\u003e\n\u003cp\u003eParameter changes are password protected and can be made directly on the loop indicator via the panel keys. Configured parameters are stored in non-volatile memory, so they're retained through a loop break.\u003c\/p\u003e\n\u003cp\u003e✅ \u003cstrong\u003e3 Year Manufacturer Warranty\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" alt=\"\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/current_loop_indicator_loopview_flyer_en.pdf?v=1735025249\" title=\"Novus LoopView Datasheet Download\" style=\"color: rgb(43, 0, 255);\"\u003eNovus LoopView Datasheet Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/PDF_32_480x480.png?v=1644302486\" width=\"32\" height=\"32\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/manual_loopview-n_v10x_b_en.pdf?v=1735025250\" title=\"Novus LoopView Manual Download\" style=\"color: rgb(43, 0, 255);\"\u003eNovus LoopView Manual Download\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003eTechnical Details\u003c\/h3\u003e\n\u003cp\u003eDisplay: 4-digit red LED display. Indicating Range: -1999 to 9999 or 9999 to -1999\u003c\/p\u003e\n\u003cp\u003eConfiguration: External push buttons. Accuracy: 0.1% of span ±1 digit. Measuring Rate: 10 measurements\/s\u003c\/p\u003e\n\u003cp\u003eData back-up: Non-Volatile EEPROM. Thermal coefficient: 0.005% \/ °C of span\u003c\/p\u003e\n\u003cp\u003eAdvanced Features: increasing or decreasing indication, alarm indication, parameters protection with password\u003c\/p\u003e\n\u003cp\u003eElectrical Connection: EN 175301-803 A standard (DIN 43650 form A). Power Supply: 4-20mA loop powered. Max current load: 60 mA\u003c\/p\u003e\n\u003cp\u003eVoltage Drop: below 10 mA \u0026lt;5.4V; 10-12 mA \u0026lt;3.9V; above 12 mA \u0026lt;2.8V\u003c\/p\u003e\n\u003cp\u003eOperation Conditions: -40 to 85°C. Dimensions: 42.5 x 52.5 x 40.7 mm. Housing material: ABS (polyurethane gasket)\u003c\/p\u003e\n\u003cp\u003eProtection Rate: IP65, NEMA4X. Certification: CE, RoHS\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a separate power supply?\u003c\/strong\u003e\u003cbr\u003eNo — LoopView is powered entirely by the 4-20mA current loop itself, so it can be retrofitted onto existing wiring with no extra wiring or power supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs it compatible with our NP640 pressure transmitters?\u003c\/strong\u003e\u003cbr\u003eYes — LoopView works with the \u003cstrong\u003e\u003ca href=\"https:\/\/www.production-automation.co.uk\/products\/novus-np640-relative-pressure-transmitter-bsp-npt-4-20ma\" style=\"color: rgb(43, 0, 255);\"\u003eNP640\u003c\/a\u003e\u003c\/strong\u003e and similar 4-20mA loop-powered transducers using the same DIN 43650 connector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat happens to my settings if the loop is interrupted?\u003c\/strong\u003e\u003cbr\u003eConfigured parameters are stored in non-volatile EEPROM, so they survive a loop break without needing reconfiguration.\u003c\/p\u003e\n\u003ch3\u003eIndustry Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransducer Upgrades\u003c\/strong\u003e — adds local digital readout to existing 4-20mA sensors with no rewiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure \u0026amp; Flow Monitoring\u003c\/strong\u003e — direct compatibility with DIN 43650-connector pressure transmitters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHarsh Environments\u003c\/strong\u003e — IP65\/NEMA4X rated for washdown or outdoor installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Do I need a separate power supply?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"No — LoopView is powered entirely by the 4-20mA current loop itself, so it can be retrofitted onto existing wiring with no extra wiring or power supply.\"}},{\"@type\":\"Question\",\"name\":\"Is it compatible with our NP640 pressure transmitters?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Yes — LoopView works with the NP640 and similar 4-20mA loop-powered transducers using the same DIN 43650 connector.\"}},{\"@type\":\"Question\",\"name\":\"What happens to my settings if the loop is interrupted?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Configured parameters are stored in non-volatile EEPROM, so they survive a loop break without needing reconfiguration.\"}}]}\n\u003c\/script\u003e","brand":"Novus","offers":[{"title":"Default Title","offer_id":54893746618741,"sku":"8817000200","price":49.82,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0501\/5794\/5002\/files\/Loopview_combo_transparente_semlogo.png?v=1735023503"}],"url":"https:\/\/www.production-automation.co.uk\/collections\/process-indicators.oembed","provider":"Production Automation","version":"1.0","type":"link"}